EX-BNS 120-11Z-3G/D
EX-BNS 120-11Z-3G/D
Produkttypebetegnelse: EX-BNS 120-(1)Z-3G/D |
(1) | |
11 | 1 sluttekontakt (NO)/1 brydekontakt (NC) |
12 | 1 sluttekontakt (NO)/2 brydekontakter (NC) |
02 | 2 brydekontakter (NC) |
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- Ø M12
- Particularly large switching distance
- Insensitive to transverse misalignment
- Suitable for food processing industry only in combination with BP 15 SS
- no mechanical wear
Ordering data
Product type description |
EX-BNS 120-11Z-3G/D |
Article number (order number) |
101184987 |
EAN (European Article Number) |
4030661333106 |
eCl@ss number, version 12.0 |
27-27-44-01 |
eCl@ss number, version 11.0 |
27-27-24-02 |
eCl@ss number, version 9.0 |
27-27-24-02 |
ETIM number, version 7.0 |
EC002544 |
ETIM number, version 6.0 |
EC002544 |
Approvals - Standards
Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration |
ATEX Zone 2 og 22 |
General data
Standards |
EN IEC 60947-5-3 |
Housing construction form |
Cylinder, med gevind |
Installation conditions (mechanical) |
Delvis planmontering |
Housing material |
Plastik, glass-fibre reinforced thermoplastic |
Gross weight |
55 g |
General data - Features
Coding |
Ja |
Short circuit detection |
Ja |
Cross-circuit detection |
Ja |
Number of normally closed (NC) |
1 |
Number of normally open (NO) |
1 |
Number of safety contacts |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
B10D- Value Normally-closed contact/Normally open contact (NC/NO) |
25.000.000 Operations |
Mechanical data
Active area |
forside |
Actuating element |
Magnet |
Switching distance actuator |
Magnetisk aktuator BP 6, Sao: 10 mm Magnetisk aktuator BP 8, Sao: 10 mm Magnetisk aktuator BP 8, Sar: 22 mm Magnetisk aktuator BP 10, Sao: 20 mm Magnetisk aktuator BP 10, Sar: 32 mm Magnetisk aktuator BP 15 SS, Sao: 20 mm Magnetisk aktuator BP 15 SS, Sar: 32 mm |
Impact energy, maximum |
2 J |
Direction of motion |
Frontal til aktiv flade |
Mechanical data - Switching distances
Assured switching distance "ON" Sao |
10 mm 20 mm |
Assured switching distance "OFF" Sar |
22 mm 32 mm |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
Mechanical data - Connection technique
Length of cable |
1 m |
Termination |
Kabel |
Wire cross-section |
0,25 mm2 |
Wire cross-section |
23 AWG |
Material of the Cable mantle |
PVC |
Mechanical data - Dimensions
ISO thread of the sensor |
M12 |
Length of sensor |
38,5 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-25 ... +70 °C |
Storage and transport temperature |
-25 ... +70 °C |
Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Electrical data
Switching voltage, maximum |
100 VAC |
Switching voltage, maximum |
100 VDC |
Switching current, maximum |
0,25 A |
Switching capacity, maximum |
5 W |
Switching element |
1 Sluttekontakt (NO), 1 Brydekontakt (NC) |
Switching frequency, maximum |
5 Hz |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
BP 10 BP 8 BP 6 BP 15 SS |
Recommended safety switchgear |
SRB-E-301ST SRB-E-201LC |
Note
Note (General) |
Kontaktsymboler vist for beskyttelsesenhedens lukkede tilstand. Sikkerhedsføleren skal monteres på en sådan måde at aktivering med en anden magnet er umulig (skjult montering i henhold til EN 1088). |
Sprog filter
Datablad
Driftsvejledning og Erklæring om konformitet
SISTEMA-VDMA bibliotek/library
Hent sidste version af Adobe Reader
Produktbillede (katalogenkeltfoto)
Dimensionstegning, grundlæggende komponent
Diagram
Karakteristisk kurve
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | EX-BNS 120 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Description of the component: | Safety sensor with magnetic operating principle in combination with the AES and SRB safety-monitoring modules from Schmersal |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013 EN ISO 14119:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 |
Conformity with SI 2016/1107 (Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations) is declared by the manufacturer without involving a conformity assessment center. |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, November 10, 2022 |
![]() |
Authorised signature Philip Schmersal Managing Director |
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | EX-BNS 120 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Description of the component: | Safety sensor with magnetic operating principle in combination with the AES and SRB safety-monitoring modules from Schmersal |
Relevant Directives: | Machinery Directive | 2006/42/EC |
Explosion Protection Directive (ATEX) | 2014/34/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-3:2013 EN ISO 14119:2013 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, October 26, 2022 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.
Udarbejdet d. 05.04.2025 12.38