SRB400NE 24V
SRB400NE 24V
- Suitable for the signal processing of outputs with contact sensors
- Possibility to connect a non-contact end switch or speed reduction switch
- 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
Ordering data
Replacement article number |
101178528 |
Product type description |
SRB400NE 24V |
Article number (order number) |
101178394 |
EAN (European Article Number) |
4250116202393 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Plastik, glass-fibre reinforced thermoplastic, ventileret |
Gross weight |
350 g |
General data - Features
Wire breakage detection |
Ja |
Cross-circuit detection |
Ja |
Removable Terminals |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of LEDs |
7 |
Number of normally closed (NC) |
4 |
Number of safety contacts |
4 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
PFH value |
2,00 x 10⁻⁸ /h |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanical data
Mechanical life, minimum |
10.000.000 Operations |
Mounting |
Hurtig montage på standard DIN-skinne iht. DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
stiv eller fleksibel Skrueforbindelse M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 … 55 Hz, amplitude 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Electrical power consumption |
6 W |
Electrical power consumption |
6 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
i ny tilstand |
Drop-out delay in case of power failure, typically |
80 ms |
Drop-out delay in case of emergency, typically |
20 ms |
Pull-in delay at automatic start, maximum, typically |
100 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
Ag-Ni, selvrensende, tvangsstyret |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
4 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
4 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-direktivet |
Status indication
Indicated operating states |
Position relæ K2 Position relæ K1 Intern driftsspænding Ui Position relæ K3 Position relæ K5 |
Other data
Note (applications) |
Sikkerhedsføler Beskyttelsessystem |
Note
Note (General) |
Induktive belastninger (f.eks. kontaktorer, relæer) skal undertrykkes med hjælp af et passende kredsløb. |
Wiring example
Note (Wiring diagram) |
Kontrollen genkender ledningsbrud og fejl i jordforbindelser i overvågningskredsløbet. Eksemplet viser en 1-kanals kontrol med kontakt A til en beskyttelsesdørsmonitor; hvor mindst én kontakt har tvangsåbning; med ekstern reset-knap (R). Relæudgange: Passende til 1 kanalkontrol, for øget kapacitet eller antal kontakter ved hjælp af kontaktorer eller relæer med positivt-guidede kontakter. Ledningsdiagrammet vises med ikke-aktiverede grænseafbrydere og i deaktiveret tilstand. (H2) = Feedback-strømkreds |
Sprog filter
Datablad
Driftsvejledning og Erklæring om konformitet
UL-certifikat
Ledningseksempel (el-ledningsføring)
SISTEMA-VDMA bibliotek/library
Hent sidste version af Adobe Reader
Produktbillede (katalogenkeltfoto)
Ledningseksempel
Ledningseksempel
Ledningseksempel
Symbol (teknisk standard)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.
Udarbejdet d. 05.05.2025 18.04