schmersal_s_icon.png

ZSD5/O.LTG.

Artikelnummer: 101199467

Downloads

ePLAN Data
CADENAS CAD Data
  • 3 levels OFF-ON-OFF
  • Thermoplastic enclosure
  • 1 Cable entry M 20 x 1.5
  • Good resistance to oil and petroleum spirit
  • Particularly fit for robot applications in accordance with the ANSI Robotics Standard
  • The redundant contact configuration enables signal processing using conventional safety relay modules
  • Contacts do not close upon reset (level 3 -> level 1)

Ordering data

Product type description

ZSD5/O.LTG.

Article number (order number)

101199467

EAN (European Article Number)

4030661521435

eCl@ss number, version 12.0

27-37-12-38

eCl@ss number, version 11.0

27-37-12-38

eCl@ss number, version 9.0

27-37-12-38

ETIM number, version 7.0

EC002571

ETIM number, version 6.0

EC002571

Approvals - Standards

Certificates

cULus

General data

Standards

CSA C22.2 Nr.14

EN IEC 60947-5-1

EN IEC 60204-1

EN IEC 60947-1

EN ISO 11161

EN ISO 12100

JIS C8201-5-1

UL508 1

Housing material

Kunststof, Termoplast, selvslukkende

Gross weight

190 g

General data - Features

Number of normally closed (NC)

1

Number of normally open (NO)

2

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

B10D Normally-closed contact (NC)

100.000 Operations

B10D Normally-open contact (NO)

100.000 Operations

Mission time

20 Year(s)

Mechanical data

Note (Mechanical life)

Lukkekontakt :
Niveau 1 - 2 - 1: 1.000.000 aktiveringer
Niveau 1 - 2 - 3 - 1: 100.000 aktiveringer

Mechanical data - Connection technique

Cable entry

1 x M20 x 1,5

Termination

Skrue terminaler

Authorised cable section, minimum

7 mm

Authorised cable section, maximum

13 mm

Cable section, minimum

0,14 mm²

Cable section, maximum

1,5 mm²

Ambient conditions

Degree of protection

IP65

Ambient temperature

-10 ... +60 °C

Storage and transport temperature

-40 ... +80 °C

Resistance to vibrations

Operation: 5 … 55 Hz, Amplitude 0,5 mm min./ Damage: 16,7 Hz, Amplitude 1,5 mm min.

Restistance to shock

Operation: 100 m/s², Damage: 1.000 m/s²

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

2,5 kV

Electrical data

Rated operating voltage

250 VAC

Operating current

3.000 mA

External wire and device fuse rating

10A f

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

i ny tilstand

Switching element

Sluttekontakter (NO, Brydekontakter (NC)

Switching principle

Klide kontakt

Maximale Schalthäufigkeit

1.200 /h

Material of the contacts, electrical

Sølv

Electrical data - Contacts

Voltage, Utilisation category AC-15

125 VAC

Current, Utilisation category AC-15

1,5 A

Voltage, Utilisation category DC-13

125 VDC

Current, Utilisation category DC-13

0,22 A

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15

125 VAC

Current, Utilisation category AC-15

1 A

Voltage, Utilisation category DC-13

125 VDC

Current, Utilisation category DC-13

0,22 A

Accessory

Recommended safety switchgear

SEB, 2-kanal med kortslutningsovervågning

Note

Note (General)

Kunde-individuelle versioner, med tilslutningskabel, er muligt på anfordring.

Overvågningsmodulet skal tilbyde muligheden for kortslutningsovervågning.

Som tilslutning er kun et dobbelt-skærmet kabel tilladt.

1)Når enheden skal bruges i fugtige rum, skal der anvendes en tilsvarende egnet tilslutningsledning.

1) Denne enhed er efterprøvet for modstandsdygtighed over for slag og fugtighed iht. UL 508.

Diagram

103043703 ZSD5CC
  • Thermoplastic enclosure
  • 1 Cable entry M 20 x 1.5
  • Good resistance to oil and petroleum spirit
  • Particularly fit for robot applications in accordance with the ANSI Robotics Standard
  • The redundant contact configuration enables signal processing using conventional safety relay modules
  • Contacts do not close upon reset (level 3 -> level 1)


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.

Udarbejdet d. 26.04.2025 07.19