SRB-E-302FWS-TS-OEM19
SRB-E-302FWS-TS-OEM19
- 2 Safety contacts, 1 Safety Output
- Plug-in screw terminals with coding
- 1 Signalling output - status safety module
- 1 Signalling output - failure massage static
- Detects standstill using 1 or 2 impulse sensors
- additional standstill signal, e.g. PLC as second input channel
- 2-channel time monitoring
Ordering data
PM_TYPE_NAME |
SRB-E-302FWS-TS-OEM19 |
PM_ORDER_NUMBER |
103041191 |
SAP_EAN |
4030661560236 |
CODE_ECLASS_V12P0 |
27-37-18-19 |
CODE_ECLASS_V11P0 |
27-37-18-19 |
CODE_ECLASS_V09P0 |
27-37-18-19 |
CODE_ETIM_V07P0 |
EC001449 |
CODE_ETIM_V06P0 |
EC001449 |
Approvals - Standards
PNV_NORM_CERTIFICATION |
cULus CCC |
General data
NORM_STANDARD |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
NORM_CLIMATIC_STRESS |
EN 60068-2-78 |
MAT_HOUSING |
Kunststoff, glasfaserverstärkter Thermoplast, belüftet |
SAP_WEIGHT_GROSS |
226 |
General data - Features
YN_ELEC_FUSE |
Ja |
YN_WIRE_BREAKAGE_DETECT |
Ja |
YN_CROSS_SHORT_DETECT |
Ja |
YN_START_INPUT |
Ja |
YN_FEEDBACK_CIRCUIT |
Ja |
YN_AUTO_RESET_FUNC |
Ja |
YN_RESET_EDGE_DETECT |
Ja |
YN_EARTH_FAULT_DETECT |
Ja |
YN_INTEGR_DISPLAY_STATUS |
Ja |
NUM_OF_IN_FOR_NC |
2 |
NUM_OF_IN_FOR_NO |
1 |
NUM_OF_LED |
6 |
NUM_OF_SAFE_CONT |
2 |
NUM_OF_SDOUT |
1 |
NUM_OF_STATUS_OUT |
2 |
Safety classification |
SAFE_NORM_STANDARD |
EN ISO 13849-1 EN IEC 62061 EN IEC 61508 |
SAFE_STOP_CAT |
0 |
Safety classification - Relay outputs |
SAFE_PERFORM_LEVEL_SROUT |
e |
SAFE_CAT_SROUT |
4 |
SAFE_DIAG_COVER_LEVEL_SROUT |
> 94 |
SAFE_PFH_VALUE_SROUT |
1,25 x 10⁻⁸ |
SAFE_PFD_VALUE_SROUT |
5,30 x 10⁻⁵ |
SAFE_SIL_SROUT |
3 |
SAFE_MISSION_TIME_SROUT |
20 |
SAFE_COMMON_CAUSE_FAIL_SROUT_MIN |
65 |
Safety classification - Fail-safe digital outputs |
SAFE_PERFORM_LEVEL_SDOUT |
e |
SAFE_CAT_SDOUT |
4 |
SAFE_PFH_VALUE_SDOUT |
2,66 x 10⁻⁹ |
SAFE_PFD_VALUE_SDOUT |
2,42 x 10⁻⁵ |
SAFE_SIL_SDOUT |
3 |
SAFE_MISSION_TIME_SDOUT |
20 |
Mechanical data
DESIGN_MECH_LIFETIME_SWITCH_MIN |
10.000.000 |
DESIGN_MOUNTING |
Schnellbefestigung für Normschiene nach DIN EN 60715 |
Mechanical data - Connection technique
APP_TERMINAL_DESIGNAT |
IEC 60947-1 |
REVIEW_ELEC_WIRING_GENERAL |
starr oder flexibel Schraubanschluss, steckbar |
ELEC_CABLE_SECTION_MIN |
0,25 mm² |
ELEC_CABLE_SECTION_MAX |
2,5 mm² |
TRQ_TIGHTEN_TERMINAL_SCREW |
0,5 |
Mechanical data - Dimensions
DIM_WIDTH_GENERAL |
22,5 |
DIM_HEIGHT_GENERAL |
98 |
DIM_DEPTH_GENERAL |
115 |
Ambient conditions
DESIGN_IP_CLASS_HOUSING |
IP40 |
DESIGN_IP_CLASS_CLEARANCE |
IP54 |
DESIGN_IP_CLASS_TERMINAL |
IP20 |
TEMP_AMB_GPV |
-25 ... +60 °C |
TEMP_STORAGE_AND_TRANSPORT_GPV |
-40 ... +85 °C |
REVIEW_RESIST_VIBRAT_EN60068_2_6 |
10 ... 55 Hz, Amplitude 0,35 mm |
REVIEW_RESTIST_TO_SHOCK |
30 g / 11 ms |
Ambient conditions - Insulation values
VOLT_RATED_INSULAT |
250 V / 50 V |
VOLT_RATED_IMPULSE_WITHSTAND_ROUT |
4 |
VOLT_RATED_IMPULSE_WITHSTAND_DOUT |
0,8 |
DESIGN_OVERVOLT_CAT_VDE100_ROMAN |
III |
DESIGN_DEG_OF_POLLUT_IEC60664_1 |
2 |
Electrical data
VOLT_OPERAT_GPV |
24 VDC -20 % / +20 % |
ELEC_RIPPLE_VOLT_MAX |
10 |
VOLT_RATED_OPERAT_DC |
24 |
CURR_RATED_OPERAT |
125 |
VOLT_RATED_CTRL_SUPPLY_DC_MIN |
19,2 |
VOLT_RATED_CTRL_SUPPLY_DC_MAX |
28,8 |
PWR_CONSUMPT_W |
3 |
ELEC_CONT_RESIST_MAX |
0,1 |
NOTE_CONT_RESIST |
in Neuzustand |
TIME_DROP_OUT_DELAY_PWR_FAIL_TYP |
10 |
TIME_DROP_OUT_DELAY_ESTOP_TYP |
10 |
TIME_ON_DELAY_AUTO_START_TYP |
150 |
TIME_ON_DELAY_AUTO_START |
Einstellbar |
TIME_ON_DELAY_RESET_TYP |
150 |
TIME_SWITCH_FREQ_MAX |
0,3 |
MAT_CONT_ELEC |
Ag-Ni, selbstreinigend, zwangsgeführt |
Electrical data - Safety digital outputs
VOLT_DROP_SDOUT_MAX |
0,5 |
CURR_LEAKAGE_SDOUT_MAX |
1 |
VOLT_UTILISAT_CAT_DC13_SDOUT |
24 |
CURR_UTILISAT_CAT_DC13_SDOUT |
2 |
Electrical data - Safe relay outputs
VOLT_UTILISAT_CAT_AC15_SROUT |
230 |
CURR_UTILISAT_CAT_AC15_SROUT |
4 |
VOLT_UTILISAT_CAT_DC13_SROUT |
24 |
CURR_UTILISAT_CAT_DC13_SROUT |
4 |
VOLT_SWITCH_CPTY_SROUT_MIN |
10 |
CURR_SWITCH_CPTY_SROUT_MIN |
10 |
VOLT_SWITCH_CPTY_SROUT_MAX |
250 |
CURR_SWITCH_CPTY_SROUT_MAX |
6 |
Electrical data - Digital inputs
ELEC_CONDUCT_RESIST_MAX |
40 |
Electrical data - Digital Output
VOLT_UTILISAT_CAT_DC12_DOUT |
24 |
CURR_UTILISAT_CAT_DC12_DOUT |
0,1 |
Electrical data - Relay outputs (auxiliary contacts)
VOLT_SWITCH_CPTY_RELAY_SUB_MAX |
24 |
CURR_SWITCH_CPTY_RELAY_SUB_MAX |
1 |
Electrical data - Electromagnetic compatibility (EMC)
NORM_EMC_INTERFERENCE_RESIST |
EMV-Richtlinie |
Status indication
STATUS_LED_OPERAT_STATE |
Interne Betriebsspannung Ui Baustein-Status Fehler-Codes |
Other data
NOTE_TYPE_OF_APP |
Sichere Stillstandsüberwachung Sicheres Zeitrelais |
Sprachfilter
Datenblatt
Betriebsanleitung und Konformitätserklärung
UL-Zertifikat
CCC-Zertifikat
SISTEMA-VDMA Bibliothek/Library
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | SRB-E-302FWS-TS |
Type: | See ordering code |
Description of the component: | Fail-safe delay timer, safe standstill monitor |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Electromagnetic Compatibility Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN ISO 13849-1:2015 EN ISO 13849-2:2012 IEC 61508 parts 1-7:2010 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Notified body, which approved the full quality assurance system, referred to in Appendix X, 2006/42/EC: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein 51105 Köln ID n°: 0035 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, March 14, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
EU-Konformitätserklärung | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Erklärung: | Hiermit erklären wir, dass die nachfolgend aufgeführten Bauteile aufgrund der Konzipierung und Bauart den Anforderungen der unten angeführten Europäischen Richtlinien entsprechen. |
Bezeichnung des Bauteils: | SRB-E-302FWS-TS |
Typ: | siehe Typenschlüssel |
Beschreibung des Bauteils: | Sicheres Zeitrelais, Sicherer Stillstandswächter |
Einschlägige Richtlinien: | Maschinenrichtlinie | 2006/42/EG |
EMV-Richtlinie | 2014/30/EU | |
RoHS-Richtlinie | 2011/65/EU |
Angewandte Normen: | EN ISO 13849-1:2015 EN ISO 13849-2:2012 IEC 61508 Teile 1-7:2010 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Benannte Stelle für die Zertifizierung des QS-Systems nach Anhang X, 2006/42/EG: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln Kenn-Nr.: 0035 |
Bevollmächtigter für die Zusammenstellung der technischen Unterlagen: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Ort und Datum der Ausstellung: | Wuppertal, 14. März 2023 |
![]() |
Rechtsverbindliche Unterschrift Philip Schmersal Geschäftsführer |
施迈赛工业开关制造(上海)有限公司, 上海市青浦区漕盈路3336号,
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 01.08.2025, 14:26