schmersal_s_icon.png

SLG 415L-E/R0500-02-PB

Artikelnummer: 101186041

Downloads

TraceParts CAD-Daten
ePLAN Daten
CADENAS CAD-Daten
SISTEMA Daten
  • integrated optic muting sensors for unilateral muting (leaving of the hazardous area)
  • 2 parallel arranged muting light beams
  • Control Category 4
  • NOTICE: Not available! (Replacement: SLG 425I)

Ordering data

Note (Delivery capacity)

Nicht mehr lieferbar!

Product type description

SLG 415L-E/R0500-02-PB

Article number (order number)

101186041

eCl@ss number, version 12.0

27-27-27-03

eCl@ss number, version 11.0

27-27-27-03

eCl@ss number, version 9.0

27-27-27-03

ETIM number, version 7.0

EC001832

ETIM number, version 6.0

EC001832

General data

Standards

EN IEC 61496-2

EN IEC 61496-1

Design of multi-ray photoelectric barrier

Sender und Empfänger getrennt

Housing material

Aluminium

Beam distance

500 mm

Reaction time, maximum

7 ms

Gross weight

8.620 g

General data - Features

Preliminary failure signal

Ja

Muting function

Ja

Override

Ja

Restart interlock (manual reset)

Ja

Beam coding available

Ja

Integral system diagnostics, status

Ja

Integral system diagnostics

Ja

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of beams

2

Safety classification

Safety type in accordance with IEC 61496-1

4

Mechanical data

Height of the protection field

510 mm

Range, protection field, minimum

0 m

Range, protection field, maximum

2,5 m

Wave length of the laserdiode

950 nm

Mechanical data - Connection technique

Termination

Steckverbinder

Terminal connector, Recipient

Einbaustecker M23, 19-polig

Terminal, Connector, Transmitter

Einbaustecker M12, 5-polig

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

60 mm

Height of sensor

776 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

+0 ... +55 °C

Storage and transport temperature

-20 ... +70 °C

Protection class

III

Electrical data

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

6 W

Electrical power consumption of the transmitter

3 W

Length of cable, maximum

100 m

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum

0,5 A

Design of control elements

p-schaltend

Scope of delivery

Scope of delivery

Sender + Empfänger, Montagewinkel, Nutensteine

Accessory

Recommended safety switchgear

SCR 402R-301

Note

Note (General)

Im Fehlerfall (Unterbrechung der 0 V Leitung) fließt ein max. Leckstrom von 0,3 mA.

Sprachfilter

Download der aktuellen Version von Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.

Generiert am: 18.08.2025, 01:21