SRB324LT 24V
SRB324LT 24V
Downloads
- wahlweise: Querschlusserkennung, manueller Reset mit Flankendetektion in Failsafe-Schaltung, automatische Reset-Funktion
- Geeignet zur Signalverarbeitung von potenzialfreien Kontakten
- Geeignet zur Signalverarbeitung von potenzialbehafteten Ausgängen (AOPD's), z.B. Sicherheits-Lichtvorhängen/-Lichtgitter
- 3 Sicherheitskontakte, STOP 0;
2 Sicherheitskontakte, STOP 1 (einstellbar 1 … 30 s) - 3 Meldeausgänge, 1 Hilfskontakt
Bestelldaten
Note (Delivery capacity) |
Nicht mehr lieferbar! |
Product type description |
SRB324LT 24V |
Article number (order number) |
101204855 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Zulassungen - Vorschriften
Certificates |
TÜV cULus |
Allgemeine Daten
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Kunststoff, glasfaserverstärkter Thermoplast, belüftet |
Gross weight |
480 g |
Allgemeine Daten - Eigenschaften
Electronic Fuse |
Ja |
Wire breakage detection |
Ja |
Cross-circuit detection |
Ja |
Removable Terminals |
Ja |
Start input |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Reset edge detection |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of auxiliary contacts |
1 |
Number of LEDs |
6 |
Number of normally closed (NC) |
2 |
Number of undelayed semi-conductor outputs with signaling function |
3 |
Number of safety contacts |
5 |
Number of signalling outputs |
3 |
Sicherheitsbetrachtung
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 1 |
Sicherheitsbetrachtung - Relaisausgänge
Performance Level, stop 0, up to |
e |
Performance Level, stop 1, up to |
d |
Category, Stop 0 |
4 |
Category, Stop 1 |
3 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
Diagnostic Coverage (DC) Level, Stop 1 |
> 60 |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
PFH value, Stop 1 |
2,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Safety Integrity Level (SIL), Stop 1, suitable for applications in |
2 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanische Daten
Mechanical life, minimum |
10.000.000 Operations |
Mounting |
Schnellbefestigung für Normschiene nach DIN EN 60715 |
Mechanische Daten - Anschlusstechnik
Terminal designations |
IEC/EN 60947-1 |
Termination |
starr oder flexibel Schraubanschluss M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanische Daten - Abmessungen
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Umgebungsbedingungen
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, Amplitude 0,35 mm |
Restistance to shock |
10 g / 11 ms |
Umgebungsbedingungen - Isolationskennwerte
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Elektrische Daten
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Electrical power consumption |
3,2 W |
Electrical power consumption |
7,1 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
in Neuzustand |
Drop-out delay in case of power failure, typically |
80 ms |
Drop-out delay in case of emergency, typically |
30 ms |
Drop-out delay in case of "emergency stop", maximum |
36 ms |
Pull-in delay at automatic start, maximum, typically |
250 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
AgSnO, Ag-Ni, selbstreinigend, zwangsgeführt |
Elektrische Daten - Digitale Eingänge
Conduction resistance, maximum |
40 Ω |
Elektrische Daten - Elektromagnetische Verträglichkeit (EMV)
EMC rating |
EMV-Richtlinie |
Zustandsanzeige
Indicated operating states |
Stellung der Relais K2 Stellung der Relais K1 Interne Betriebsspannung Ui Stellung der Relais K3 |
Sonstige Daten
Note (applications) |
Sicherheits-Sensor Schutzeinrichtung NOT-HALT-Taster Seilzug-Notschalter Sicherheits-Lichtvorhang |
Hinweis
Note (General) |
Induktive Verbraucher (Schütze, Relais etc.) sind durch eine geeignete Beschaltung zu entstören. |
Schaltungsbeispiel
Note (Wiring diagram) |
Das Schaltungsbeispiel ist bei geschlossenen Schutzeinrichtungen und im spannungslosen Zustand dargestellt. Leistungsebene: 2-kanalige Ansteuerung geeignet zur Kontaktverstärkung bzw. Kontaktvervielfältigung durch Schütze oder Relais mit zwangsgeführten Kontakten. Die Ansteuerung erkennt Querschlüsse, Drahtbrüche und Erdschlüsse im Überwachungskreis. 2-kanalige Ansteuerung dargestellt am Beispiel einer Schutztürüberwachung mit zwei Kontakten, davon mindestens ein Kontakt zwangsöffnend; mit externem Reset-Taster (R). (H2) = Rückführkreis |
Sprachfilter
Datenblatt
Betriebsanleitung und Konformitätserklärung
TÜV-Zertifikat
UL-Zertifikat
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Schaltungsbeispiel
Funktionsweise
Symbol (technischer Standard)
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.