AZM 161B-ST1-FB-RA

Item number: 103034789

Product type description:
AZM161 (1)-(2)(3)K(4)-(5)/(6)(7)(8)

(1)
SKScrew connection
CCCage clamps
STConnector plug M12

(2)
11/03Magnet: 1 NO contact, 1 NC contact / Actator: 3 NC contacts with connector plug
12/03Magnet: 1 NO contact, 2 NC contact / Actator: 3 NC contacts
12/11

Magnet: 1 NO contact, 2 NC contacts / Actator: 1 NO contact, 1 NC contact with connector plug

11/12Magnet: 1 NO contact, 1 NC contacts / Actator: 1 NO contact, 2 NC contact with connector plug
12/12

Magnet: 1 NO contact, 2 NC contacts / Actator: 1 NO contact, 2 NC contacts


(3)
withoutLatching force 5 N
RLatching force 30 N

(4)
withoutPower to unlock
APower to lock

(5)
withoutLateral manual release
EDManual release on the cover side
TLateral emergency exit
TDEmergency exit on the cover side
NEmergency release

(6)
withoutwithout Emergency exit on the rear side
TUEmergency exit on the rear side
EUManual release on the rear side

(7)
024Us: 24 VAC/DC
110/230Us: 110/230 VAC

(8)
withoutwithout LED
Gwith LED (only for Us: 24 VAC/DC)
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • Device version for connection to a Safety-Field-Box SFB
  • connector plug M12, 8-pole
  • Thermoplastic enclosure
  • Double-insulated
  • Interlock with protection against incorrect locking.
  • 130 mm x 90 mm x 30 mm
  • 6 Contacts
  • Long life

Ordering data

Product type description

AZM 161B-ST1-FB-RA

Article number (order number)

103034789

EAN (European Article Number)

4030661541778

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

cULus

General data

Standards

EN ISO 13849-1

EN ISO 14119

EN IEC 60947-5-1

Coding level according to EN ISO 14119

Low

Working principle

electromechanical

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Material of the contacts, electrical

Silver

Gross weight

451 g

General data - Features

Power to lock

Yes

Manual release

Yes

Number of actuating directions

3

Number of auxiliary contacts

1

Number of safety contacts

2

Safety classification

Standards

EN ISO 13849-1

Mission time

20 Year(s)

Safety classification - Safety outputs

B10D Normally-closed contact (NC)

2,000,000 Operations

B10D Normally open contact (NO)

1,000,000 Operations

Note (B10D Normally open contact (NO))

at 10% Ie and ohmic load

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Actuating play in direction of actuation

5.5 mm

Holding force FZh in accordance with EN ISO 14119

2,000 N

Holding force Fmax, maximum

2,600 N

Latching force

30 N

Positive break travel

10 mm

Positive break force per NC contact, minimum

10 N

Positive break force, minimum

20 N

Actuating speed, maximum

2 m/s

Mechanical data - Connection technique

Termination

Connector plug M12, 8-pole, (A-coding)

Mechanical data - Dimensions

Length of sensor

30 mm

Width of sensor

130 mm

Height of sensor

90 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Permissible installation altitude above sea level, maximum

2,000 m

Storage and transport temperature

-25 ... +85 °C

Ambient conditions - Insulation values

Rated insulation voltage Ui

Connector, 8 poles - 60 V

Rated impulse withstand voltage Uimp

0.8 kV

Rated impulse withstand voltage, connector 8-pole

0.8 kV

Electrical data

Thermal test current

2 A

Rated control voltage

24 VAC/DC

Required rated short-circuit current

1,000 A

Electrical power consumption, maximum

10 W

Switching element

NO contact, NC contact

Switching principle

Slow action

Switching frequency

1,000 /h

Electrical data - Magnet control

Magnet switch-on time

100 %

Test pulse duration, maximum

5 ms

Test pulse interval, minimum

50 ms

Electrical data - Safety contacts

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

2 A

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

2 A

Other data

Note (applications)

sliding safety guard

removable guard

hinged safety guard

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Note

Note (Manual release)

For maintenance, installation, etc.

For manual release using M5 triangular key, available as accessory

Diagram


Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 31/01/2023, 06:30