AZM400Z-ST-I2-1P2P-BOW

Item number: 103015315

Downloads

ePLAN Data
CADENAS CAD Data
Product type description:

AZM400Z(1)(2)(3)(4)(5)


(1)
ST1 Connector plug M12, 8-pin
ST22 Connector plug M12, 8-pin / 5-pin

(2)
withoutStandard coding
I1Individual coding
I2Individual coding, multiple teaching

(3)
1P2P1 serial diagnostic output and 2 p-type safety outputs (only for ST)
2P2P2 serial diagnostic output and 2 p-type safety outputs (only for ST2)

(4)
withoutManual release
TEmergency exit
BOWWith securing holes for Bowden cable assembly

(5)
withoutwithout electronic manual release (Only for ST)
Ewith electronic manual release (Only for ST2)
Not all component variants, which are possible according to this order code are available and/or technically feasible.
  • Repeated individual coding with RFID technology
  • Universal coding with RFID technology
  • Connector M12, 8-pole
  • Guard locking monitored
  • 1 Diagnostic output
  • With securing holes for Bowden cable assembly
  • Bistable, motor-driven system
  • Clamping force 10.000
  • Release possible against lateral forces up to 300 N
  • PL e / cat. 4 / SIL 3 for interlocking and guard locking function
  • Two-channel input signal of the guard locking function
  • Operation on P/P- and P/N-switching outputs
  • High tolerance to door misalignment

Ordering data

Product type description

AZM400Z-ST-I2-1P2P-BOW

Article number (order number)

103015315

EAN (European Article Number)

4030661503967

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

EAC

FCC

IC

General data

Standards

EN ISO 13849-1

EN ISO 14119

EN IEC 60947-5-3

EN IEC 61508

Coding

Individual coding, multiple teaching

Coding level according to EN ISO 14119

High

Working principle

Magnetic field

RFID

Enclosure material

Light alloy die-casting

Gross weight

856 g

Time to readiness, maximum

1,500 ms

Reaction time, maximum

100 ms

General data - Features

Solenoid interlock monitored

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Securing holes for Bowden cable assembly

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of diagnostic signals

1

Number of safety contacts

2

Safety classification

Standards

EN ISO 13849-1

EN IEC 61508

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

1.00 x 10⁻⁹ /h

PFD value

9.00 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety classification - Guard locking function

Performance Level, up to

e

Category

4

PFH value

1.80 x 10⁻⁹ /h

PFD value

1.60 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Interlocking principle

bistable

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

Which have a lateral force Ftrans = 100 N: 100.000 operations

Minimum distance devices

30 mm

Holding force FZh in accordance with EN ISO 14119

10,000 N

Holding force Fmax, maximum

13,000 N

Lateral force at bolt return, maximal (against locked door)

300 N

Note (Lateral force at bolt return)

Does not apply to emergency exit, Bowden cable and manual release

Tightening torque of the screw

8 Nm

Tightening torque of the fixing screws Bowden cable

1.2 Nm

Mechanical data - Connection technique

Termination

Connector M12, 8-pole

Mechanical data - Dimensions

Length of sensor

46.7 mm

Width of sensor

77.8 mm

Height of sensor

166.7 mm

Ambient conditions

Degree of protection

IP67

IP66

Ambient temperature, minimum

-20 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-40 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Current consumption

100 mA

Current consumption, maximum

600 mA

Current consumption at 24V, minimum

10 mA

Current consumption at 24V, maximum

15 mA

No-load supply current I0, maximum

100 mA

Rated operating voltage

24 VDC

Rated operating voltage

24 VDC

Operating current

50 mA

Required rated short-circuit current

100 A

Switching frequency, approx.

0.3 Hz

Open / close cycle (motor), minimum

3

Minimal average cycle time (with continuous operation)

20 s

Electrical data - Control inputs

Switching thresholds of the control inputs

−3 V … 5 V (Low)

15 V … 30 V (High)

Allowable discrepancy time (input), maximum

10 s

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital inputs

Classification ZVEI CB24I, Sink

C1

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

2 V

Leakage current Ir, maximum

1.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic outputs

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

OUT2 Diagnostic output 2

PIN 2

E1 Control input 1

PIN 3

n.c.

PIN 4

Y1 Safety output 1

PIN 5

OUT1 Diagnostic output 1

PIN 6

E3 Control input 3

PIN 7

Y2 Safety output 2

PIN 8

E2 Control input 2

Scope of delivery

Scope of delivery

The Bowden cable is not included in delivery.

Note: Versions AZM400Z-...-BOW may only be used in connection with Bowden cable release ACC-AZM400-BOW-.M-.M, which is available as an accessory. Use without the Bowden cable release fitted is not permissible.

Scope of delivery of mounting material

2 x M6 (10.9)

Accessory

Recommendation (actuator)

AZM400-B1

Language filter

Operating instructions and Declaration of conformity

EAC certification

UKCA Declaration of Conformity

SISTEMA-VDMA library

Download the latest version of Adobe Reader

Video ID: azm400-01

ID: azm400-01

Single device connection | 16.2 MB | .mp4

Video ID: azm400-02

ID: azm400-02

Tolerance to misalignment | 20.9 MB | .mp4

Video ID: azm400-03

ID: azm400-03

Opening in case of uptighted doors | 22.3 MB | .mp4

Video ID: azm400-04

ID: azm400-04

Safety function in case of voltage breakdown | 19.6 MB | .mp4

Video ID: azm400-05

ID: azm400-05

Block driver | 15.7 MB | .mp4

Video ID: azm400-06

ID: azm400-06

Cross-fault with controlled shut-down process | 19.3 MB | .mp4

Video ID: azm400-08

ID: azm400-08

Replacement actuator AZM300-I | 18.1 MB | .mp4

Video ID: azm400-09

ID: azm400-09

Teaching of a replacement actuator AZM300-I2 | 18.5 MB | .mp4


K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal

The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.

Generated on: 06/12/2022, 20:04