RSS 36-AD-ST-AS
RSS 36-AD-ST-AS
Product type description: RSS 36-(1)-ST-AS-(2) |
(1) | |
without | Standard coding |
AD | Standard coding, actuator detection |
I1 | Individual coding |
I2 | Individual coding, for multiple applications |
(2) | |
without | without latching |
R | with latching, latching force approx. 18 N |
- Universal coding with RFID technology
- without latching
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- optionally with integrated magnetic latching
Ordering data
Product type description |
RSS 36-AD-ST-AS |
Article number (order number) |
103001535 |
EAN (European Article Number) |
4030661426396 |
eCl@ss number, version 12.0 |
27-27-46-01 |
eCl@ss number, version 11.0 |
27-27-24-03 |
eCl@ss number, version 9.0 |
27-27-24-03 |
ETIM number, version 7.0 |
EC001829 |
ETIM number, version 6.0 |
EC001829 |
Approvals - Standards
Certificates |
TÜV cULus ASi-SaW ANATEL |
General data
Standards |
EN IEC 62026-2 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding |
Universal coding |
Coding level according to EN ISO 14119 |
Low |
Working principle |
RFID |
Frequency band RFID |
125 kHz |
Transmitter output RFID, maximum |
-6 dB/m |
Housing construction form |
Block |
Installation conditions (mechanical) |
not flush |
Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Reaction time, maximum |
100 ms |
Duration of risk, maximum |
200 ms |
Gross weight |
104 g |
General data - Features
Safety functions |
Yes |
Integral system diagnostics, status |
Yes |
Number of actuating directions |
3 |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
5.13 x 10⁻¹⁰ /h |
PFD value |
3.24 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical life, minimum |
1,000,000 Operations |
Note (Mechanical life) |
Actuating speed < 0.25 m/s Operations for door weights ≤ 5 kg |
Type of the fixing screws |
2x M4 (cylinder head screws with washers DIN 125A / form A) |
Tightening torque of the fixing screws, minimum |
2.2 Nm |
Tightening torque of the fixing screws, maximum |
2.5 Nm |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switch distance, typical |
12 mm |
Assured switching distance "ON" Sao |
10 mm |
Assured switching distance "OFF" Sar |
20 mm |
Hysteresis (Switching distance), maximum |
2 mm |
Repeat accuracy R |
0.5 mm |
Note (Repeat accuracy R) |
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm. |
Mechanical data - Connection technique
Termination |
Connector plug M12, 4-pole, (A-coding) |
Mechanical data - Dimensions
Length of sensor |
22 mm |
Width of sensor |
106.3 mm |
Height of sensor |
25 mm |
Ambient conditions
Degree of protection |
IP65 IP67 IP69 |
Ambient temperature |
-25 ... +70 °C |
Storage and transport temperature |
-25 ... +85 °C |
Relative humidity, maximum |
93 % |
Note (Relative humidity) |
non-condensing non-icing |
Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
III |
Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0.8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Time to readiness, maximum |
5,000 ms |
Switching frequency, maximum |
1 Hz |
Electrical data - AS Interface
Rated operating voltage |
18 ... 31.6 VDC (Protection against polarity reversal) |
AS-i Current consumption, maximum |
100 mA |
Electrical data - AS-Interface specification
AS-i Specification |
Safety-Slave |
AS-i Version |
V 3.0 |
AS-i Profile |
S-0.B.F.E |
AS-i, IO-Code |
0x0 |
AS-i, ID-Code |
0xB |
AS-i, ID-Code1 |
0xF |
AS-i, ID-Code2 |
0xE |
AS-i Input, Channel 1 |
Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 |
Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 … DO 3 |
No Function |
AS-i Parameter bits, P0 |
Number actuator 01-15 (binary) |
AS-i Parameter bits, P1 |
Number actuator 01-15 (binary) |
AS-i Parameter bits, P2 |
Number actuator 01-15 (binary) |
AS-i Parameter bits, P3 |
Number actuator 01-15 (binary) |
Note (AS-i Parameter bits) |
Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address |
0 |
Note (AS-i Input module address) |
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
Note (LED switching conditions display) |
(1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active (2) yellow LED: device condition (enabling status) / hysteresis signal / device error |
Pin assignment
PIN 1 |
AS-Interface + |
PIN 2 |
n.c. (≤ 30 VDC) |
PIN 3 |
AS-Interface - |
PIN 4 |
n.c. (≤ 30 VDC) |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
RST 36-1-AD01…15 |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UKCA certificate
ANATEL certification
Info
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 4/25/2024, 1:23 PM