schmersal_s_icon.png

EX-BNS 250-12Z-2187-3G/D 25,0M

Tuotenumero: 101208546

Downloads

TraceParts CAD tiedosto
ePlan Tiedot
CADENAS CAD tiedosto
  • Thermoplastic enclosure
  • small body
  • Concealed mounting possible
  • 33 mm x 25 mm x 13 mm
  • Long life
  • no mechanical wear
  • Insensitive to transverse misalignment
  • Insensitive to soiling

Ordering data

Note (Delivery capacity)

Ei saatavana!

Product type description

EX-BNS 250-12Z-2187-3G/D 25,0M

Article number (order number)

101208546

EAN (European Article Number)

4030661380612

eCl@ss number, version 12.0

27-27-44-01

eCl@ss number, version 11.0

27-27-24-02

eCl@ss number, version 9.0

27-27-24-02

ETIM number, version 7.0

EC002544

ETIM number, version 6.0

EC002544

Approvals - Standards

Certificates

ATEX (Konformitätserklärung)

Explosion protection

Explosion protection: regulations

EN IEC 60079-0

EN IEC 60079-15

EN 60079-31

Explosion protection zones

2

22

Explosion protection category

3G

3D

Explosion protection designation

D II 3G Ex nC IIC T6 Gc X

D II 3D Ex tc IIIC T80°C Dc X

Manufacturer declaration

ATEX Zone 2 and 22

General data

Housing construction form

lohko

Installation conditions (mechanical)

ei uppoasenteinen

Housing material

Muovi, lasikuituvahvistettu kestomuoviMuovi, lasikuituvahvistettu kestomuovi

Gross weight

1 030 g

General data - Features

Coding

Kyllä

Prerequisite evaluation unit

Kyllä

Number of cable wires

6

Safety classification

Vorschriften

EN ISO 13849-1

Mission time

20 Year(s)

Safety classification - Safety outputs

B10D- Value Normally-closed contact/Normally open contact (NC/NO)

25 000 000 Operations

Mechanical data

Actuating element

Solenoidi

Impact energy, maximum

7 J

Direction of motion

Edessä aktiiviseen pintaan

Mechanical data - Switching distances

Assured switching distance "ON" Sao

4 mm

Assured switching distance "OFF" Sar

14 mm

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-3

Mechanical data - Connection technique

Length of cable

25 m

Termination

kaapeli

Wire cross-section

0,25 mm2

Wire cross-section

23 AWG

Material of the Cable mantle

PVC

Mechanical data - Dimensions

Length of sensor

13 mm

Width of sensor

33 mm

Height of sensor

25 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +70 °C

Storage and transport temperature

-25 ... +70 °C

Resistance to vibrations

10 … 55 Hz, Amplitudi 1 mm

Restistance to shock

30 g / 11 ms

Electrical data

Switching voltage, maximum

24 VDC

Switching current, maximum

0,1 A

Switching capacity, maximum

1 W

Switching frequency, maximum

5 Hz

Electrical data - Digital Output

Design of control elements

Muut, Reed-koskettimet

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Accessory

Recommendation (actuator)

EX-BPS 250-3G/D

Recommended safety switchgear

SRB-E-301ST

SRB-E-201LC

Note

Note (General)

Contact symbols shown for the closed condition of the guard device.

The contact configuration for versions with or without LED is identical.

Kielisuodatin

Lattaa Adobe Readerin viimeisin versio

103045526 EX-BNS 250-12Z-2187-3GD 25M
  • Explosion protection for ATEX Zones 2 and 22
  • Thermoplastic enclosure
  • Insensitive to transverse misalignment
  • no mechanical wear
  • as simple electrical apparatus for intrinsically safe current circuits (Ex i) to Ex-Zone 0 and 20
  • 64 mm x 29.5 mm x 15.5 mm (incl. protective enclosure)


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Tiedot ja arvot on tarkastettu huolellisesti. Kuvat voivat poiketa alkuperäisestä. Tarkemmat tekniset tiedot löytyvät manuaalista. Pidätämme oikeuden teknisiin muutoksiin ja virheisiin.

Luotu: 9.5.2025 0.01