PROTECT-SELECT-SK
PROTECT-SELECT-SK
- Simple and flexible parameter setting
- No programming skills required
- 18 safe inputs for the redundant inquiry of all common safety sensors
- 4 safety semi-conductor outputs
- 2 safety relay outputs
- 4 optional signalling outputs
- Replaces up to 8 safety-monitoring modules up to PL e / SIL 3
- Error and status messages in plain text
- Multilingual menu navigation via colour display
Ordering data
Note (Delivery capacity) |
Ei saatavana! |
Product type description |
PROTECT-SELECT-SK |
Article number (order number) |
101218030 |
EAN (European Article Number) |
4030661445397 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
TÜV cULus CCC |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-1 EN 60068-2-2 EN 61496 |
Housing material |
Polyamide / V0 |
Gross weight |
300 g |
General data - Features
Short circuit detection |
Kyllä |
Wire breakage detection |
Kyllä |
Cross-circuit detection |
Kyllä |
Removable Terminals |
Kyllä |
Start input |
Kyllä |
Feedback circuit |
Kyllä |
Automatic reset function |
Kyllä |
Reset edge detection |
Kyllä |
Start-up test |
Kyllä |
Earth connection detection |
Kyllä |
Integral system diagnostics, status |
Kyllä |
Integrated Display, Supply Voltage |
Kyllä |
Number of pulse outputs (test pulse output) |
3 |
Number of relay outputs (1-channel) |
2 |
Number of fail-safe analogue inputs |
2 |
Number of digital fail-safe inputs |
14 |
Number of digital fail-safe in-/outputs |
4 |
Number of fail-safe digital outputs |
4 |
Number of signalling outputs |
4 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 62061 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
Diagnostic Coverage (DC) Level |
99 |
PFH value |
1,78 x 10⁻⁸ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Hardware fault tolerance (HFT) |
1 |
Demand rate |
korkea tai jatkuva |
Safe Failure Fraction (SFF), minimum |
90 |
Safety classification - Relay outputs |
Performance Level, up to |
e |
Category |
4 |
Notice |
Koskee kaksikanavaista sovellusta ja 60 % relekuormaa |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Safety classification - Safety inputs 2-channels |
Performance Level, up to |
e |
Category |
4 |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Safety classification - Safety inputs 1-channel |
Performance Level, up to |
d |
Category |
2 |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Safety classification - Safety outputs 1-channel |
Performance Level, up to |
d |
Category |
2 |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Safety classification - Safety outputs 2-channels |
Performance Level, up to |
e |
Category |
4 |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mechanical data
Mechanical life, minimum |
10 000 000 Operations |
Mounting |
Pikakiinnitys DIN-kiskoon standardin DIN EN 60715 mukaan |
Mechanical data - Connection technique
Terminal designations |
IEC 61131-2 IEC/EN 60947-1 |
Termination |
Jäykkä tai taipuisa |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Terminal (mechanical) |
Irrotettavat ruuviliittimet |
Mechanical data - Dimensions
Width |
52,5 mm |
Height |
100 mm |
Depth |
118 mm |
Ambient conditions
Degree of protection |
IP20 |
Degree of protection of the mounting space |
IP54 |
Ambient temperature |
-25 ... +55 °C |
Storage and transport temperature |
-25 ... +75 °C |
Relative humidity, minimum |
15 % |
Relative humidity, maximum |
90 % |
Note (Relative humidity) |
ei kondensoitumista |
Resistance to vibrations |
10 … 57 Hz, Amplitudi 0,75 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Operating voltage |
12 VDC -10 % / +10 % |
Current consumption at 24V, maximum |
500 mA |
No-load supply current I0, typical |
500 mA |
Rated operating voltage |
12 VDC |
Required rated short-circuit current |
1 000 A |
Note (Electrical data, Fuse rating) |
hidas |
Switching frequency, maximum |
0,1 Hz |
Material of the contacts, electrical |
Tina |
Electrical fuse rating, maximum |
3 A |
Electrical data - Safety digital inputs
Switching thresholds |
-3 V … 2 V (LOW) 18 V … 28,8 V |
Current consumption at 24 V |
6 mA |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) |
700 mA |
Design of control elements |
Oikosulkusuojattu, PNP / NPN (Q0/0N und Q1/1N) Oikosulkusuojattu, PNP (Q2 ja Q3) |
Leakage current Ir, maximum |
2 mA |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-1 |
250 VAC |
Current, Utilisation category AC-1 |
4 A |
Voltage, Utilisation category DC-1 |
24 VDC |
Current, Utilisation category DC-1 |
4 A |
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
3 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
4 A |
Electrical data - Diagnostic outputs
Operating current |
100 mA |
Design of control elements |
Limited short-circuit protection, p-type |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Directive |
Other data
Note (applications) |
Turvatunnistin suojus Hätäpysäytyspainikkeet Köysihätäpysäyttimet Turvavaloverho |
Kielisuodatin
Tuotelehti
Käyttöohjeet ja vaatimuksenmukaisuusvakuutus
EU-vaatimuksenmukaisuusvakuutus
UKCA Declaration of Conformity
Esite
SISTEMA-VDMA. Kirjasto
Lattaa Adobe Readerin viimeisin versio
Tuotekuva( luettelokuva)
Merkki (tekninen standardi)
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | PROTECT SELECT-CC 1) 1) SYS firmware: 1.1.7 or higher Hardware: FOMP or higher |
Type: | See ordering code (standard version) |
Description of the component: | Multifunctional safety controller |
Relevant Directives: | Machinery Directive | 2006/42/EC |
EMC-Directive | 2014/30/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN ISO 13850:2015 EN ISO 13849-1:2023 IEC 61508 parts 1-7:2010 |
Notified body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
EC-Type Examination Certificate: | 01/205/5352.02/24 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, July 9, 2024 |
![]() |
Authorised signature Philip Schmersal Managing Director |
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | PROTECT-SELECT-CC 1) 1) SYS firmware: 1.1.7 or higher Hardware: FOMP or higher |
Type: | See ordering code (standard version) |
Description of the component: | Multifunctional safety controller |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Electromagnetic Compatibility Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN ISO 13850:2015 EN ISO 13849-1:2023 IEC 61508 parts 1-7:2010 |
Approved body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
Type examination certificate: | 01/205/5352.02/24 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, July 9, 2024 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Tiedot ja arvot on tarkastettu huolellisesti. Kuvat voivat poiketa alkuperäisestä. Tarkemmat tekniset tiedot löytyvät manuaalista. Pidätämme oikeuden teknisiin muutoksiin ja virheisiin.
Luotu: 14.4.2025 4.40