NAS 311 ST1-AS

Numéro d'article: 101173041

Téléchargements

TraceParts Données
ePLAN Données
CADENAS Données CAO
  • Thermoplastic actuators
  • Emergency stop station
  • AS-Interface M12 connector
  • 85 mm x 85 mm x 97,8 mm
  • Integrated AS-Interface
  • Pull to reset
  • Resistant to chemicals

Ordering data

Product type description

NAS 311 ST1-AS

Article number (order number)

101173041

EAN (European Article Number)

4030661448831

eCl@ss number, version 12.0

27-37-12-44

eCl@ss number, version 11.0

27-37-12-44

eCl@ss number, version 9.0

27-37-12-44

ETIM number, version 7.0

EC002034

ETIM number, version 6.0

EC002034

Approvals - Standards

Certificates

TÜV

ASi-SaW

General data

Standards

EN IEC 62026-2

EN ISO 13849-1

EN ISO 13850

EN IEC 60947-5-1

EN IEC 61508

Housing material

Plastique

Gross weight

330 g

Safety classification

Vorschriften

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

1,40 x 10⁻⁸ /h

Note (PFH-value)

jusqu'à max. 5 000 manoeuvres/a n

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data - Connection technique

Connector position

En bas

Termination

Connecteur intégré M12, 4 pôles, codage A

Mechanical data - Dimensions

Length of sensor

97,8 mm

Width of sensor

85 mm

Height of sensor

85 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

-25 ... +60 °C

Storage and transport temperature

-25 ... +85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

sans condensation

non givrant

Electrical data

Current consumption

50 mA

Electrical data - AS Interface

Rated operating voltage

26,5 ... 31,6 VDC (Protection against polarity reversal)

Electrical data - AS-Interface specification

AS-i Version

V 2.1

AS-i Profile

S-7.B.0.E

AS-i, IO-Code

0x7

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Bits de données DI 0/DI 1 = transmission de code dynamique

AS-i Input, Channel 2

Données de bits DI 2/ DI 3 = transmission de code dynamique

AS-i Outputs, DO 0 … DO 3

Sans fonction

AS-i Parameter bits, P0 ... P3

Sans fonction

AS-i Input module address

0

Note (AS-i Input module address)

Préréglée sur l'adresse 0, modifiable via le maître AS-Interface ou l’appareil d’adressage portative

Pin assignment

PIN 1

AS-i +

PIN 2

n.c.

PIN 3

AS-Interface -

PIN 4

n.c.