  • 2 safety contacts, STOP 0
  • 6 Signalling outputs
  • Multi-evaluation of up to 6 safety guards
  • Suitable for the signal processing of outputs with contact sensors

Ordering data

Note (Delivery capacity)

Plus disponible!

Replacement article number

101177165

Product type description

SRB206ST 24V AC/DC

Article number (order number)

101173536

EAN (European Article Number)

4250116201853

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

cULus

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Plastique, thermoplastique renforcée de fibres de verre, ventilée

Gross weight

250 g

General data - Features

Electronic Fuse

Oui

Wire breakage detection

Oui

Removable Terminals

Oui

Start input

Oui

Feedback circuit

Oui

Automatic reset function

Oui

Reset edge detection

Oui

Earth connection detection

Oui

Integral system diagnostics, status

Oui

Number of auxiliary contacts

6

Number of LEDs

4

Number of normally closed (NC)

12

Number of safety contacts

2

Number of signalling outputs

6

Safety classification

Vorschriften

EN IEC 60947-5-1

EN IEC 61508

Stop-Category

0

Safety classification - Relay outputs

Performance Level, stop 0, up to

d

Category, Stop 0

3

Diagnostic Coverage (DC) Level, Stop 0

> 60 %

PFH value, Stop 0

2,00 x 10⁻⁷ /h

Safety Integrity Level (SIL), Stop 0, suitable for applications in

3

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Mechanical data

Mechanical life, minimum

10 000 000 Operations

Mounting

Fixation rapide sur rails DIN standards selon DIN EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

rigide ou flexible

Raccord fileté M20 x 1.5

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +45 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

10...55 Hz, amplitude 0,35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Operating voltage

24 VAC -15 % / +10 %
24 VDC -15 % / +20 %

Ripple voltage

10 %

Rated operating voltage

24 VAC

Rated operating voltage

24 VDC

Operating current

275 mA

Rated AC voltage for controls, 50 Hz, minimum

20,4 VAC

Rated control voltage at AC 50 Hz, maximum

26,4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20,4 VAC

Rated control voltage at AC 60 Hz, maximum

26,4 VAC

Rated AC voltage for controls at DC minimum

20,4 VDC

Rated control voltage at DC, maximum

28,8 VDC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

6 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

6 A

Electrical power consumption

3,6 W

Electrical power consumption

6,6 VA

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

à l'état neuf

Drop-out delay in case of "emergency stop", maximum

30 ms

Pull-in delay at RESET, typically

50 ms

Material of the contacts, electrical

AgCdO, autonettoyant, à guidage forcé

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

Directive CEM

Status indication

Indicated operating states

Position relais K2

Position relais K1

Tension de service interne Ui

Other data

Note (applications)

Dispositif de protection

Bouton d'arrêt d'urgence

Interrupteurs de sécurité à commande par câble

Note

Note (General)

Des charges inductives (p.ex. relais externe, etc.) doivent être antiparasitées par un dispositif approprié.

Wiring example

Note (Wiring diagram)

L'exemple de câblage est représenté pour les protecteurs fermés et hors tension.

Démarrage automatique: le démarrage automatique est configuré par le raccordement de la boucle de retour aux bornes X1/X3. Si la boucle de retour n'est pas utilisée, établir un pont.

Niveau d'entrée: l'exemple reprend une commande à 2 canaux d'une surveillance de protecteur avec deux interrupteurs de position, dont un avec ouverture forcée, un bouton de réarmement externe (R) et une boucle de retour (H2).

La commande reconnaît les ruptures et les fuites à la terre dans le circuit de surveillance.

Partie puissance: une commande à 2 canaux convient pour le renforcement ou la multiplication des contacts par contacteurs ou relais avec contacts à guidage forcé.

Si un nombre supérieur de protecteurs est surveillé, il faut les raccorder conformément au tableau de raccordement.

Une défaillance simple des capteurs n'entraîne pas la perte de la sécurité.

En cas d'une défaillance unique, la fonction de sécurité sera toujours maintenue. Certaines erreurs, pas toutes, seront reconnues. Une accumulation d'erreurs non reconnues pourra entraîner la perte de la fonction de sécurité.


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.

Généré le: 18/04/2025 08:03