PS116-T12-ST-J203
PS116-T12-ST-J203
- only for positioning tasks
- Thermoplastic enclosure
- Symmetric enclosure
- Lever angle adjustable in 15° steps
- Protection class IP66, IP67
- Actuator heads can be repositioned by 8 x 45°
- Design to EN 50047
Ordering data
Product type description |
PS116-T12-ST-J203 |
Article number (order number) |
103010001 |
EAN (European Article Number) |
4030661468693 |
eCl@ss number, version 12.0 |
27-27-06-01 |
eCl@ss number, version 11.0 |
27-27-06-01 |
eCl@ss number, version 9.0 |
27-27-06-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
Certificates |
cULus CCC |
General data
Standards |
EN IEC 60947-5-1 |
Housing construction form |
Construction normée |
Housing material |
Plastique, thermoplastique renforcé de fibres de verre, zamac injecté, chromaté |
Active area |
métal |
Gross weight |
122 g |
General data - Features
Number of auxiliary contacts |
1 |
Mechanical data
Actuating element |
Levier antenne J200 |
Mechanical life, minimum |
10 000 000 Operations |
Positive break force, minimum |
40 N |
Actuating speed, minimum |
60 mm/min |
Actuating speed, maximum |
1 m/s |
Actuating torque, minimum |
0,2 Nm |
Positive break torque |
0,6 Nm |
Mechanical data - Connection technique
Connector position |
En bas |
Termination |
Connecteur M12, 6 pôles |
Wire cross-section |
0,5 mm2 |
Terminal (mechanical) |
en bas |
Mechanical data - Dimensions
Length x Width x Height |
Hauteur du capteur: 169 mm (tige au milieu) |
Length of sensor |
16,6 mm |
Width of sensor |
31 mm |
Diameter of the Rod |
6 mm |
Length of the lever |
200 mm |
Ambient conditions
Degree of protection |
IP66 IP67 |
Ambient temperature |
-30 ... +80 °C |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
300 V |
Rated impulse withstand voltage Uimp |
4 kV |
Degree of pollution |
3 |
Electrical data
Required rated short-circuit current |
400 A |
Utilisation category AC-15 |
240 VAC |
Utilisation category AC-15 |
1,5 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1,5 A |
Switching element |
1 contact NO, 2 contacts NF |
Switching principle |
contacts à action dépendante |
Bounce duration, maximum |
3 ms |
Maximale Schalthäufigkeit |
5 000 /h |
Switchover time, maximum |
5,5 ms |
Material of the contacts, electrical |
Argent |
Filtre de langue
Fiches techniques
Mode d'emploi (annexe/guide raccourci)
Certificat UL
Certification CCC
Brochure
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Plan d'encombrement actionneur
Diagramme des contacts
Diagramme de contact
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | PS116, PS215, PS216, PS226, PS315, PS316 |
Type: | See ordering code |
Description of the component: | Position switch |
Relevant Directives: | Low Voltage Directive | 2014/35/EU |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, March 3, 2021 |
![]() |
Authorised signature Philip Schmersal Managing Director |
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | PS116, PS215, PS216, PS226, PS315, PS316 |
Type: | See ordering code |
Description of the component: | Position switches |
Relevant legislation: | Electrical Equipment (Safety) Regulations | 2016 |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-1:2017 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, August 19, 2021 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 08/04/2025 04:22