Product type description:
EX-SVE(1)/(2)-24VDC

(1)
11 key-operated selector switches
22 key-operated selector switches
33 key-operated selector switches

(2)
...Key number
Nie wszystkie urządzenia, które są możliwe do uzyskania przy pomocy tego klucza zamówieniowego, są dostępne i/lub możliwe do realizacji pod względem technicznym.

Ordering data

Product type description

EX-SVE1/106-24VDC

Article number (order number)

103015368

EAN (European Article Number)

4030661503844

eCl@ss number, version 12.0

27-37-12-43

eCl@ss number, version 11.0

27-37-12-43

eCl@ss number, version 9.0

27-37-12-43

ETIM number, version 7.0

EC001029

ETIM number, version 6.0

EC001029

Approvals - Standards

Certificates

ATEX (Konformitätserklärung)

Explosion protection

Explosion protection: regulations

EN IEC 60079-0

EN 60079-31

Explosion protection category

3D

Explosion protection designation

Ex tc IIIC T85°C Dc X

Manufacturer declaration, zone

22

General data

Standards

EN ISO 13849-1

EN ISO 14119

EN IEC 60947-5-1

Working principle

elektromechaniczne

Housing material

Tworzywo sztuczne, tworzywo​​ termoplastyczne​​ wzmocnione​​ włóknem​​ szklanym,​ samogasnące​

Colour of the housing

Czarne

Srebro

Colour of the key

Srebro

Colour of key head

Srebro

Gross weight

1.020 g

General data - Features

Power to unlock

Tak

Manual release

Tak

Number of key selector switch

1

Safety classification

Mission time

20 Year(s)

Safety classification - Safety outputs

B10D Normally-closed contact (NC)

100.000 Operations

Mechanical data

Position of the Key selector switch

wycentrowane

Mechanical life, minimum

100.000 Operations

Key number

106

Mechanical data - Connection technique

Termination

Połączenie śrubowe M20 x 1.5

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Note

Wszystkie odniesienia do przekroju przewodów uwzględniają końcówki kablowe.

Mechanical data - Dimensions

Length

144 mm

Width

96 mm

Height

169 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

+0 ... +50 °C

Ambient conditions - Insulation values

Rated insulation voltage Ui

250 VAC

Rated impulse withstand voltage Uimp

2,5 kV

Electrical data

Thermal test current

4 A

Rated control voltage

24 VDC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

4 A

Electrical power consumption, maximum

8,5 W

Switching element

zestyk (NO), zestyk (NC)

Switching principle

Wolnoprzełączające

Material of the contacts, electrical

Srebro

Scope of delivery

Scope of delivery

Klucz i trójkątne narzędzie wchodzi w zakres dostawy (wraz z 1 kluczem awaryjnym): klucz i trójkątne narzędzie wchodzi w zakres dostawy (wraz z 1 kluczem awaryjnym)

Note

Note (General)

Patrz ilustracja: Sposób działania: Klucz 1-3 w poz. 1. Magnes niezasilony: przełącznik kluczowy zablokowany, zestyki NC zamknięte, wyjęcie klucza zablokowane
Klucz 1-3 w poz. 1. Magnes zasilony, zestyk NC otwarty: przełącznik kluczowy odblokowany, zestyki NC zamknięte, wyjęcie klucza zablokowane
Klucz 1-3 w poz. 2. Magnes zasilony, zestyk NC otwarty: przełącznik kluczowy odblokowany, zestyki NC otwarte, wyjęcie klucza odblokowane

Trójkątne narzędzie do zwolnienia ręcznego w Poz. 4: przełącznik kluczowy odblokowany mechanicznie, Magnet außer Funktion, Öffnerkontakt geöffnet
Dreikantwerkzeug für Hilfsentriegelung in Pos.4: Magnet in Funktion

UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:EX-SHGVD II 2GD Ex h 85°C X
 EX-SHGV/ESSD II 3G Ex ic IIC T5 Gc X
D II 3D Ex tc IIIC T110°C Dc X
 EX-SVED II 3D Ex tc IIIC T85°C Dc X
Type:See ordering code
Description of the component:Interlocking device with electromagnetic interlock for safety functions
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:EN 60947-5-1:2017
ISO 14119:2014
ISO 13849-1:2015
EN IEC 60079-0:2018
EN 60079-11:2012
EN 60079-31:2014
EN ISO 80079-36:2016
EN ISO 80079-37:2016
Approved body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Type examination certificate:01/205/5754.00/20
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a conformity assessment center.
Place and date of issue:Wuppertal, March 7, 2023
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director
Deklaracja zgodności UE LOG_COM_lo1de01s
Oryginał



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Niemcy
Internet: www.schmersal.com
Wyjaśnienie:Niniejszym oświadczamy, że niżej wymienione elementy konstrukcyjne spełniają wymagania podanych niżej Europejskich Dyrektyw w zakresie koncepcji i konstrukcji.
Oznaczenie elementu konstrukcyjnego:EX-SHGVD II 2GD Ex h 85°C X
 EX-SHGV/ESSD II 3G Ex ic IIC T5 Gc X
D II 3D Ex tc IIIC T110°C Dc X
 EX-SVED II 3D Ex tc IIIC T85°C Dc X
Typ:patrz klucz zamówieniowy
Opis elementu konstrukcyjnego:Blokada elektromagnetyczna dla funkcji bezpieczeństwa
Odnośne dyrektywy:Dyrektywa maszynowa2006/42/EG
 Dyrektywa ATEX2014/34/EU
 Dyrektywa RoHS2011/65/EU
Zastosowane normy:EN 60947-5-1:2017
ISO 14119:2014
ISO 13849-1:2015
EN IEC 60079-0:2018
EN 60079-11:2012
EN 60079-31:2014
EN ISO 80079-36:2016
EN ISO 80079-37:2016
Jednostka notyfikowana do badania typu:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
Nr ident.: 0035
Certyfikat badania typu WE:01/205/5754.00/20
Osoba upoważniona do sporządzenia dokumentacji technicznej:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Zgodność z dyrektywą dotyczącą ochrony przeciwwybuchowej 2014/34/UE (ATEX) jest deklarowana przez producenta bez włączania jednostki certyfikującej.
Miejscowość i data wystawienia:Wuppertal, 23 stycznia 2023
 GRA_SIG_ksig-y24
 Prawnie wiążący podpis
Philip Schmersal
Dyrektor

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Dane zostały starannie sprawdzone. Zdjęcia mogą odbiegać od rzeczywistości. Dalsze dane techniczne znajdują się w instrukcji obsługi. Możliwe są zmiany i błędy techniczne.

Wygenerowano dnia 21.07.2025, 14:22