schmersal_s_icon.png

AES 1102.3 24 VAC

Varenummer: 101128797

Downloads

TraceParts CAD Data
ePlan Data
CADENAS CAD Data
  • Monitoring of BNS range magnetic safety sensors
  • 1 safety contact, STOP 0

Ordering data

Note (Delivery capacity)

Ikke tilgjengelig!

Product type description

AES 1102.3 24 VAC

Article number (order number)

101128797

EAN (European Article Number)

4030661278858

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

cULus

General data

Standards

BG-GS-ET-14

BG-GS-ET-20

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-3

BG-GS-ET-14

Housing material

Plast, glassfiber forsterket termoplast, ventilert

Gross weight

124 g

General data - Features

Wire breakage detection

Ja

Automatic reset function

Ja

Reset after disconnection of supply voltage

Ja

Integral system diagnostics, status

Ja

Number of LEDs

1

Number of normally closed (NC)

4

Number of normally open (NO)

2

Number of safety contacts

1

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Stop-Category

0

Safety classification - Relay outputs

Performance Level, up to

c

Category

1

PFH value

1,14 x 10⁻⁶ /h

Notice

Inntil maks. 50 000 omkoblingssykluser/år og ved maks. 80% kontaktbelastning

Safety Integrity Level (SIL), suitable for applications in

1

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

3 000 000 Operations

Mounting

kneppes inn på standard DIN-skinne iht. EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

Stiv eller fleksibel

Skrueforbindelse M20 x 1.5

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Mechanical data - Dimensions

Width

22,5 mm

Height

75 mm

Depth

110 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

+0 ... +55 °C

Storage and transport temperature

-25 ... +70 °C

Resistance to vibrations

10...55 Hz, Amplitude 0,35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Thermal test current

4 A

Rated operating voltage

24 VAC

Rated AC voltage for controls, 50 Hz, minimum

20,4 VAC

Rated control voltage at AC 50 Hz, maximum

26,4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20,4 VAC

Rated control voltage at AC 60 Hz, maximum

26,4 VAC

Electrical power consumption

2,4 W

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

I ny tilstand

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Material of the contacts, electrical

AgCdO

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

250 VAC

Current, Utilisation category AC-15

1,5 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

1 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0,1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Autorisert operasjon

Other data

Note (applications)

Sikkerhetssensor

sikkerhetsinnretning

Note

Note (General)

Induktive belastninger (f.eks. kontaktorer, reléer, etc.) må undertrykkes ved hjelp av en egnet krets.

Wiring example

Note (Wiring diagram)

For å sikre en eller flere vaktdører opp til PL c og kategori 1

Overvåke et antall vernedører med magnetiske sikkerhetssensorer i BNS-serien

Kablingsskjemaet vises med vernedørene lukket og i de-energisert tilstand.

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:AES 1102
AES 1112
Type:See ordering code
Description of the component:Safety-monitoring module for non-contact safety switches and safety relay combination in connection with the BNS series magnetic safety switches
Relevant Directives:Machinery Directive2006/42/EC
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-3:2013
EN ISO 13849-1:2015
EN ISO 13849-2:2012
Notified body, which approved
the full quality assurance system,
referred to in Appendix X, 2006/42/EC:
TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, December 16, 2021
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.

Generert til 25.03.2025, 03:00