schmersal_s_icon.png

AES 1135-2185

项目编号: 101195947

下载

追踪备件 CAD数据
计划 数据
CADENAS CAD数据
  • Monitoring of BNS range magnetic safety sensors
  • 1 safety contact, STOP 0
  • 2 Signalling outputs

Ordering data

Note (Delivery capacity)

不支持!

Product type description

AES 1135-2185

Article number (order number)

101195947

EAN (European Article Number)

4030661363370

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Notice

停售产品

Approvals - Standards

Certificates

cULus

General data

Standards

BG-GS-ET-14

BG-GS-ET-20

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-3

BG-GS-ET-14

Housing material

玻璃纤维加固热塑塑料,带通风

Gross weight

195 g

General data - Features

Wire breakage detection

Cross-circuit detection

Automatic reset function

Reset after disconnection of supply voltage

Earth connection detection

Integral system diagnostics, status

Number of LEDs

1

Number of normally closed (NC)

2

Number of normally open (NO)

1

Number of undelayed semi-conductor outputs with signaling function

2

Number of safety contacts

1

Number of signalling outputs

2

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Stop-Category

0

Safety classification - Relay outputs

Performance Level, up to

d

Category

3

PFH value

1.00 x 10⁻⁷ /h

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

20,000,000 Operations

Mounting

DIN导轨快速安装,依据EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

硬线或软线

螺丝端子 M20 x 1.5

Cable section, minimum

.25 mm²

Cable section, maximum

2.5 mm²

Tightening torque of Clips

0.6 Nm

Mechanical data - Dimensions

Width

22.5 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

+0 ... +55 °C

Storage and transport temperature

-25 ... +70 °C

Resistance to vibrations

10 ... 55 Hz,振幅 .35 mm,± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Operating voltage

24 VAC -15 % / +10 %
24 VDC -10 % / +20 %

Ripple voltage

10 %

Thermal test current

6 A

Rated operating voltage

24 VAC

Rated operating voltage

24 VDC

Rated AC voltage for controls, 50 Hz, minimum

20.4 VAC

Rated control voltage at AC 50 Hz, maximum

26.4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20.4 VAC

Rated control voltage at AC 60 Hz, maximum

26.4 VAC

Rated AC voltage for controls at DC minimum

20.4 VDC

Rated control voltage at DC, maximum

28.8 VDC

Electrical power consumption

5 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

处于全新的状态

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Material of the contacts, electrical

Ag-Ni 10和.2 µm 镀金

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

6 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

6 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Input signal, HIGH Signal "1"

10 … 30 VDC

Input signal, LOW Signal "0"

0 … 2 VDC

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC指令

Integral system diagnosis (ISD)

Note (ISD -Faults)

以下故障由安全监控模块记录并由ISD显示。

Faults

安全继电器不能吸合或断开

门触点无法打开或关闭

开关连接的交叉线或短路监控

开关连接中断

安全监控模块的输入电路或继电器控制电路故障

Other data

Note (applications)

安全传感器

防护系统

Note

Note (General)

感应负载(例如接触器、继电器等)必须通过适当的电路抑制。

Wiring example

Note (Wiring diagram)

接线图显示的是防护门关闭且处于断电状态的情况。

用于确保防护门可以符合PL d和类别3

检测1扇防护门,带有BNS系列的磁性安全传感器

如果一个或两个外置继电器或触点被用于调节负载,此系统仅可被归类为EN ISO 13849-1中的种类3,如果排除故障“外部触点故障”可以得到证实并记录在案,例如通过使用可靠的降额触点。第二个触点通过冗余切换关闭负载来提高安全级别。

2个NC触点的修改:安全监控模块可以通过桥接端子A1和X1来监控2个NC触点。在这种配置下,短路检测不起作用。

启用延迟时间的扩展:通过改变装置盖下跳线连接的位置,可以将启用延迟时间从.1s增加到1.0s。

用于分析故障指示及其原因的ISD表(综合系统诊断)如附录所示。

语言条件

下载最新版本的Adobe Reader

103009970 SRB-E-201LC
  • Plug-in screw terminals with coding
  • STOP 0 Function
  • 1 oder 2-channel control
  • Start button / Auto-start
  • 2 Safety outputs 2 A
  • 1 Signalling output

103007672 SRB-E-301ST
  • Plug-in screw terminals with coding
  • STOP 0 Function
  • 1 oder 2-channel control
  • Start button / Auto-start
  • 1 Auxiliary contact
  • 3 safety contacts


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。