schmersal_s_icon.png

AZM 200CC-T-1P2P

Varenummer: 101179701

Downloads

TraceParts CAD Data
ePlan Data
CADENAS CAD Data
Produkt-typebetegnelse:

AZM 200(1)(2)-T-(3)(4)


(1)
utenVernelås overvåket >
BAktivator overvåket

(2)
SKSkrueforbindelse
CCFjærtrinseforbindelse
ST1Konnektor M23 x 1, 8+1-polet)
ST2Konnektor M12 x 1, 8-polet)

(3)
1P2P1 diagnoseutgang og 2 sikkerhetsutganger, p-type
1P2PWlik - 1P2P, kombinert diagnosesignal: vaktdør lukket og forriglingsenhet låst
SD2PSeriell diagnoseutgang og 2 sikkerhetsutganger, p-type

(4)
utenåpner med spenning
Adriftsspenning
Ikke alle mulige maskiner med denne typenøkkelen kan leveres og/eller er teknisk omsettelige.
  • Guard locking monitored
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Max. length of the sensor chain 200 m
  • Self-monitoring series-wiring
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
  • Manual release

Ordering data

Note (Delivery capacity)

Ikke tilgjengelig!

Product type description

AZM 200CC-T-1P2P

Article number (order number)

101179701

EAN (European Article Number)

4030661312699

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

cULus

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 61508

Working principle

induktiv

Housing material

Plast, glassfiber forsterket termoplast

Reaction time, maximum

60 ms

Duration of risk, maximum

120 ms

Gross weight

535 g

General data - Features

Power to unlock

Ja

Solenoid interlock monitored

Ja

Manual release

Ja

Short circuit detection

Ja

Cross-circuit detection

Ja

Series-wiring

Ja

Safety functions

Ja

Integral system diagnostics, status

Ja

Number of safety contacts

2

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Mission time

20 Year(s)

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

4,00 x 10⁻⁹ /h

PFD value

1,00 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety classification - Guard locking function

Performance Level, up to

d

Category

2

PFH value

2,50 x 10⁻⁹ /h

PFD value

2,20 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1 000 000 Operations

Holding force FZh in accordance with EN ISO 14119

2 000 N

Note (clamping force FZh)

1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use.

Holding force Fmax, maximum

2 600 N

Note (clamping force Fmax)

1.300 N in Verbindung mit einem Betätiger AZ/AZM201-B30 für Innenanbau.

Latching force

30 N

Actuating speed, maximum

0,2 m/s

Tightening torque of the fastening screws for the housing cover, minimum

0,7 Nm

Tightening torque of the fastening screws for the housing cover, maximum

1 Nm

Note

Torx T10

Mechanical data - Connection technique

Termination

Fjærtrinseforbindelse

Cable section, minimum

0,25 mm²

Cable section, maximum

1,5 mm²

Note

Alle indikasjoner om kabelsnittet inkluderer lederhylsene.

Wire cross-section, minimum

23 AWG

Wire cross-section, maximum

15 AWG

Wire cross-section

23 ... 15 AWG

Allowed type of cable

solid single-wire

solid multi-wire

flexible

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

40 mm

Height of sensor

220 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +60 °C

Storage and transport temperature

-25 ... +85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

ikke kondenserende

Resistance to vibrations

10 … 55 Hz, Amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0,8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

No-load supply current I0, typical

600 mA

Rated operating voltage

24 VDC

Operating current

50 mA

Time to readiness, maximum

4 000 ms

Switching frequency, approx.

1 Hz

Electrical data - Magnet control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Magnet switch-on time

100 %

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24 V

5 mA

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Voltage drop Ud, maximum

4 V

Leakage current Ir, maximum

0,5 mA

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,25 A

Electrical data - Diagnostic outputs

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0,05 A

Status indication

Note (LED switching conditions display)

Koblingsforhold: gul lysdiode

Feil funksjonell defekt: rød lysdiode

Tilførselsspenning UB: grønn lysdiode

Scope of delivery

Scope of delivery

Actuator must be ordered separately.

Trekantnøkkel for AZM 200

Accessory

Recommendation (actuator)

AZ/AZM 200-B1

Note

Note (General)

Så lenge aktueringsenheten forblir satt inn i den magnetiske forriglingen, kan den ulåste sikkerhetsvakten låses på nytt. Sikkerhetsutgangene vil så bli aktivert igjen. Det er derfor ikke nødvendig å åpne vakten.

EU Conformity Declaration
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:AZM 200
Type:See ordering code
Description of the component:Interlocking device with electromagnetic interlock for safety functions
Relevant Directives:Machinery Directive2006/42/EC
 EMC-Directive2014/30/EU
 RoHS-Directive2011/65/EU
Applied standards:EN 60947-5-3:2013
ISO 14119:2013
EN ISO 13849-1:2015
EN 61508 parts 1-7:2010
EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Notified body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
EC-Type Examination Certificate:01/205/5122.02/20
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, May 12, 2020
  GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.

Generert til 24.03.2025, 09:08