EX-TS 235-11Z-3D
EX-TS 235-11Z-3D
- Metal enclosure
- Wide range of alternative actuators
- Good resistance to oil and petroleum spirit
- 30 mm x 63,5 mm x 30 mm
- Actuator heads can be repositioned by 4 x 90°
- Mounting details to EN 50047
- 1 Cable entry M 20 x 1.5
- Ex-Zone 2 and 22
Ordering data
Product type description |
EX-TS 235-11Z-3D |
Article number (order number) |
101186288 |
EAN (European Article Number) |
4030661326924 |
eCl@ss number, version 12.0 |
27-27-26-01 |
eCl@ss number, version 11.0 |
27-27-26-01 |
eCl@ss number, version 9.0 |
27-27-26-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
Manufacturer declaration |
ATEX Zone 2 et 22 |
General data
Standards |
BG-GS-ET-15 EN IEC 60947-5-1 |
Housing construction form |
Construction normée |
Actuator type to EN 50047 |
B |
Housing material |
Métal, zamac injecté |
Housing coating material |
laquée |
Gross weight |
192 g |
General data - Features
Safety functions |
Oui |
Number of auxiliary contacts |
1 |
Number of safety contacts |
1 |
Safety classification |
Vorschriften |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
20.000.000 Operations |
Mechanical data
Actuating element |
Poussoir |
Mechanical life, minimum |
20.000.000 Operations |
Actuating force, minimum |
9 N |
Positive break force, minimum |
19 N |
Actuating speed, minimum |
60 mm/min |
Actuating speed, maximum |
1 m/s |
Note Bounce duration |
Temps de rebond selon la vitesse d'actionnement |
Note (Switchover time) |
Temps de commutation selon la vitesse d'actionnement |
Mechanical data - Connection technique
Termination |
Raccord fileté M20 x 1.5 |
Cable cross-section of the cable glands, minimum |
7 mm |
Cable cross-section of the cable glands, maximum |
12 mm |
Cable section, minimum |
0,75 mm² |
Cable section, maximum |
2,5 mm² |
Note |
Toutes les indications relatives à la section du câble sont embouts compris. |
Wire cross-section |
13 AWG |
Mechanical data - Dimensions
Length of sensor |
30 mm |
Width of sensor |
30 mm |
Height of sensor |
75,5 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-20 ... +60 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
500 V |
Rated impulse withstand voltage Uimp |
6 kV |
Electrical data
Thermal test current |
10 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
4 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1 A |
Switching element |
Contact NO, contact NF |
Switching principle |
contacts à action dépendante |
Maximale Schalthäufigkeit |
5.000 /h |
Material of the contacts, electrical |
Argent |
Scope of delivery
Scope of delivery |
Presse-étoupe antidéflagrante |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Bibliothèque/Library SISTEMA-VDMA
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Plan d'encombrement composant de base
Plan d'encombrement actionneur
Diagramme des contacts
Diagramme de contact
Déclaration UE de conformité | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Déclaration: | Par la présente, nous certifions que les composants identifiés ci-après répondent de par leur conception et leur construction aux exigences des Directives Européennes applicables. |
Désignation du composant: | EX-Z/T 235 |
Type: | voir exemple de commande |
Marquage: | D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
Description du composant: | Interrupteur de position à manoeuvre positive d'ouverture |
Directives pertinentes: | Directive ATEX Constructeur (Atmosphères Explosibles) | 2014/34/EU |
Directive RoHS | 2011/65/EU |
Normes appliquées: | EN 60947-5-1:2017 + AC:2020 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 |
La conformité avec la directive ATEX 2014/34/EU est attestée par le fabricant sans l' intervention d' un organisme de certification de la conformité. |
Représentant autorisé à préparer et composer la documentation technique: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Lieu et date de l'émission: | Wuppertal, le 7 septembre 2023 |
![]() |
Signature à l'effet d'engager la société Philip Schmersal Président Directeur Général |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 02/08/2025 19:57