SLC 415I-E/R0610-90-12

Artikelnummer: 101170445

Downloads

TraceParts CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
  • NOTICE: Not available! (Replacement: SLC 425I)
  • Control Category 4

Ordering data

Note (Delivery capacity)

Leveres ikke længere!

Product type description

SLC 415I-E/R0610-90-12

Article number (order number)

101170445

eCl@ss number, version 12.0

27-27-27-04

eCl@ss number, version 11.0

27-27-27-04

eCl@ss number, version 9.0

27-27-27-04

ETIM number, version 7.0

EC002549

ETIM number, version 6.0

EC002549

General data

Standards

EN IEC 61496-2

EN IEC 61496-1

Housing material

Aluminium

Reaction time, maximum

9 ms

General data - Features

Muting function

Ja

Override

Ja

Restart interlock (manual reset)

Ja

Beam coding available

Ja

Integral system diagnostics, status

Ja

Integral system diagnostics

Ja

Number of fail-safe digital outputs

2

Number of beams

9

Safety classification

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

90 mm

Height of the protection field

610 mm

Range, protection field, minimum

0 m

Range, protection field, maximum

16 m

Wave length of the laserdiode

950 nm

Mechanical data - Connection technique

Termination

Tilslutning

Terminal connector, Recipient

Indbygningsstik M23, 19 polet

Terminal, Connector, Transmitter

Indbygningsstik M12, 5 polet

Length of the connectable cable, maximum

100 m

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

60 mm

Height of sensor

736 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

+0 ... +55 °C

Storage and transport temperature

-20 ... +70 °C

Protection class

III

Electrical data

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

6 W

Electrical power consumption of the transmitter

3 W

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum

0,5 A

Design of control elements

P-type

Scope of delivery

Scope of delivery

Sender + modtager, monteringsvinkelbeslag, T-spor

Accessory

Recommended safety switchgear

SCR 402R-301

Note

Note (General)

I tilfælde af fejl (afbrydelse af 0 V forsyningen) er den højeste lækkende strøm 0,3 mA.

2 eller 4 dæmpende følere kan forbindes.

Dæmpningsfølerne (f.eks. LF 50) skal bestilles separat.


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

De nævnte data og angivelser er blevet checket omhyggeligt. Billeder kan afvige fra originalen. Der kan findes flere tekniske data i manualen. Der tages forbehold for tekniske ændringer og fejl.

Udarbejdet d. 05.04.2025 05.13