schmersal_s_icon.png

SLC 415I-E/R0760-40-12

Codice prodotto: 101170415

Downloads

TraceParts CAD
ePLAN Dati
CADENAS CAD Data
SISTEMA Dati
  • NOTICE: Not available! (Replacement: SLC 425I)
  • Control Category 4

Ordering data

Note (Delivery capacity)

Non più disponibile!

Product type description

SLC 415I-E/R0760-40-12

Article number (order number)

101170415

eCl@ss number, version 12.0

27-27-27-04

eCl@ss number, version 11.0

27-27-27-04

eCl@ss number, version 9.0

27-27-27-04

ETIM number, version 7.0

EC002549

ETIM number, version 6.0

EC002549

General data

Standards

EN IEC 61496-2

EN IEC 61496-1

Housing material

Alluminio

Reaction time, maximum

15 ms

Gross weight

2.760 g

General data - Features

Muting function

Override

Restart interlock (manual reset)

Beam coding available

Integral system diagnostics, status

Integral system diagnostics

Number of fail-safe digital outputs

2

Number of beams

25

Safety classification

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

40 mm

Height of the protection field

760 mm

Range, protection field, minimum

0 m

Range, protection field, maximum

16 m

Wave length of the laserdiode

950 nm

Mechanical data - Connection technique

Termination

collegamento ad innesto

Terminal connector, Recipient

Connettore maschio incorporato M23, 19 poli

Terminal, Connector, Transmitter

Connettore maschio incorporato M12, 5 poli

Length of the connectable cable, maximum

100 m

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

60 mm

Height of sensor

886 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

+0 ... +55 °C

Storage and transport temperature

-20 ... +70 °C

Protection class

III

Electrical data

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

6 W

Electrical power consumption of the transmitter

3 W

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum

0,5 A

Design of control elements

con commutazione p

Scope of delivery

Scope of delivery

trasmettitore + ricevitore, angolo di montaggio, chiocciola

Accessory

Recommended safety switchgear

SCR 402R-301

Note

Note (General)

In caso di errore (Interruzione del cavo 0 V) fuoriesce una corrente massima di fuga di 0.3 mA.

Si possono collegare 2 o 44 sensori Muting.

I sensori Muting (ad es. LF 50) vanno ordinati separatamente.

Filtro lingua

Download dell'ultima versione di Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.

Generato il 31/03/2025, 04:53