SLC 420-E/R0570-30-69-RFB
SLC 420-E/R0570-30-69-RFB
Product type description: SLC 420-E/R(1)-(2)-69-RFB |
(1) | |
0170 | Protection field height 170 mm |
0250 | Protection field height 250 mm |
0330 | Protection field height 330 mm |
0410 | Protection field height 410 mm |
0490 | Protection field height 490 mm |
0570 | Protection field height 570 mm |
0650 | Protection field height 650 mm |
0730 | Protection field height 730 mm |
0810 | Protection field height 810 mm |
0890 | Protection field height 890 mm |
0970 | Protection field height 970 mm |
1050 | Protection field height 1050 mm |
1130 | Protection field height 1130 mm |
1210 | Protection field height 1210 mm |
1290 | Protection field height 1290 mm |
1370 | Protection field height 1370 mm |
1450 | Protection field height 1450 mm |
(2) | |
14 | Resolution 14 mm (Range 0.3 …) 7 m |
30 | Resolution 30 mm (Range 0.3 …) 10 m |
- Protection class IP69K
- Safety type 4 in accordance with IEC 61496-1
- Resolution 14 mm and 30 mm
- Protection field height from 170 mm … 1450 mm
Ordering data
Note (Delivery capacity) |
Plus disponible! |
Product type description |
SLC 420-E/R0570-30-69-RFB |
Article number (order number) |
101206957 |
eCl@ss number, version 12.0 |
27-27-27-04 |
eCl@ss number, version 11.0 |
27-27-27-04 |
eCl@ss number, version 9.0 |
27-27-27-04 |
ETIM number, version 7.0 |
EC002549 |
ETIM number, version 6.0 |
EC002549 |
Approvals - Standards
Certificates |
TÜV cULus |
General data
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Housing material |
Aluminium |
Reaction time, maximum |
10 ms |
Gross weight |
3950 g |
General data - Features
Restart interlock (manual reset) |
Oui |
Beam coding available |
Oui |
Blanking function |
Oui |
Integral system diagnostics, status |
Oui |
Integral system diagnostics |
Oui |
Number of fail-safe digital outputs |
2 |
Number of beams |
28 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
6,19 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
4 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
30 mm |
Height of the protection field |
570 mm |
Range, protection field, minimum |
0,3 m |
Range, protection field, maximum |
10 m |
Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
Length of cable |
5 m |
Termination |
Connecteur |
Terminal connector, Recipient |
Câble avec connecteur M12, 8 pôles |
Terminal, Connector, Transmitter |
Câble avec connecteur M12, 4 pôles |
Length of the connectable cable, maximum |
100 m |
Mechanical data - Dimensions
Diameter of sensor |
60 mm |
Height of sensor |
667 mm |
Ambient conditions
Degree of protection |
IP69K |
Ambient temperature |
-10 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Protection class |
III |
Electrical data
Switching voltage OSSD, HIGH signal |
24 V |
Electrical power consumption of the receiver |
8 W |
Electrical power consumption of the transmitter |
4 W |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
0,5 A |
Design of control elements |
commutation P |
Scope of delivery
Scope of delivery |
Kit avec 2 équerres de montage |
Accessory
Recommended safety switchgear |
SRB-E 301 |
Note
Note (General) |
Im En cas de défaillance (interruption de l’alimentation 0 V), le courant de fuite max. est de 1 mA. |
Filtre de langue
Fiches techniques
Instructions de montage et de câblage
Mode d'emploi et déclaration de conformité
Certificat CE avec examen de type
Certificat UL
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Type de contact
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 2025-04-07 18 h 45