schmersal_s_icon.png

SLC 425I-E/R0730-30-RFBC

Artikelnummer: 101207556

Downloads

TraceParts CAD-Daten
ePLAN Daten
CADENAS CAD-Daten
Product type description:

SLC 425I-E/R(1)-(2)-RFBC


(1)
0170Protection field height 170 mm
0250Protection field height 250 mm
0330Protection field height 330 mm
0410Protection field height 410 mm
0490Protection field height 490 mm
0570Protection field height 570 mm
0650Protection field height 650 mm
0730Protection field height 730 mm
0810Protection field height 810 mm
0890Protection field height 890 mm
0970Protection field height 970 mm
1050Protection field height 1050 mm
1130Protection field height 1130 mm
1210Protection field height 1210 mm
1290Protection field height 1290 mm
1370Protection field height 1370 mm
1450Protection field height 1450 mm
1530Protection field height 1530 mm (only for resolution 30 mm)
1610Protection field height 1610 mm (only for resolution 30 mm)
1690Protection field height 1690 mm (only for resolution 30 mm)
1770Protection field height 1770 mm (only for resolution 30 mm)

(2)
14Resolution 14 mm
30Resolution 30 mm
Nicht alle nach diesem Typenschlüssel möglichen Geräte sind lieferbar und/oder technisch umsetzbar.
  • Protection class IP67
  • Safety type 4 in accordance with IEC 61496-1
  • Integrated muting und override function
  • 1 … 8 Cycles

Ordering data

Note (Delivery capacity)

Nicht mehr lieferbar!

Product type description

SLC 425I-E/R0730-30-RFBC

Article number (order number)

101207556

eCl@ss number, version 12.0

27-27-27-04

eCl@ss number, version 11.0

27-27-27-04

eCl@ss number, version 9.0

27-27-27-04

ETIM number, version 7.0

EC002549

ETIM number, version 6.0

EC002549

Approvals - Standards

Certificates

cULus

General data

Standards

EN IEC 61496-2

EN IEC 61496-1

Housing material

Aluminium

Reaction time, maximum

15 ms

Gross weight

3.480 g

General data - Features

Muting function

Ja

Override

Ja

Clock control possible

Ja

Restart interlock (manual reset)

Ja

Beam coding available

Ja

Blanking function

Ja

Integral system diagnostics, status

Ja

Integral system diagnostics

Ja

Number of fail-safe digital outputs

2

Number of beams

36

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

7,42 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

30 mm

Height of the protection field

730 mm

Range, protection field, minimum

0,3 m

Range, protection field, maximum

10 m

Wave length of the laserdiode

880 nm

Mechanical data - Connection technique

Termination

Steckverbinder

Terminal connector, Recipient

Einbaustecker M12, 8-polig

Terminal, Connector, Transmitter

Einbaustecker M12, 4-polig

Length of the connectable cable, maximum

100 m

Mechanical data - Dimensions

Height of transmitter

815 mm

Height of Receiver

879 mm

Diameter of sensor

49 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-10 ... +50 °C

Storage and transport temperature

-25 ... +70 °C

Protection class

III

Electrical data

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

8 W

Electrical power consumption of the transmitter

4 W

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum

0,5 A

Design of control elements

p-schaltend

Scope of delivery

Scope of delivery

Sender + Empfänger, Befestigungsset

Accessory

Recommended safety switchgear

SRB-E 301

Note

Note (General)

Im Fehlerfall (Unterbrechung der 0 V Leitung) fließt ein max. Leckstrom von 1 mA.

Sprachfilter

Download der aktuellen Version von Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.

Generiert am: 28.03.2025, 23:46