schmersal_s_icon.png

SRB324LT 24V

Artikelnummer: 101204855

Downloads

TracePart CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
  • Optional: Short-circuit recognition, Manual reset with edge detection in fail-safe circuit, Automatic reset function
  • Suitable for the signal processing of outputs with contact sensors
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • 3 safety contacts, STOP 0;
    2 safety contacts, STOP 1 (adjustable 1 … 30 s)
  • 3 Signalling outputs, 1 Auxiliary contact

Ordering data

Note (Delivery capacity)

Ej tillgänglig!

Product type description

SRB324LT 24V

Article number (order number)

101204855

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

TÜV

cULus

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Plast, glasfiberarmerad termoplast, ventilerad

Gross weight

480 g

General data - Features

Electronic Fuse

Ja

Wire breakage detection

Ja

Cross-circuit detection

Ja

Removable Terminals

Ja

Start input

Ja

Feedback circuit

Ja

Automatic reset function

Ja

Reset edge detection

Ja

Earth connection detection

Ja

Integral system diagnostics, status

Ja

Number of auxiliary contacts

1

Number of LEDs

6

Number of normally closed (NC)

2

Number of undelayed semi-conductor outputs with signaling function

3

Number of safety contacts

5

Number of signalling outputs

3

Safety classification

Vorschriften

EN IEC 60947-5-1

EN IEC 61508

Stop-Category

0

1

Safety classification - Relay outputs

Performance Level, stop 0, up to

e

Performance Level, stop 1, up to

d

Category, Stop 0

4

Category, Stop 1

3

Diagnostic Coverage (DC) Level, Stop 0

≥ 99 %

Diagnostic Coverage (DC) Level, Stop 1

> 60 %

PFH value, Stop 0

2,00 x 10⁻⁸ /h

PFH value, Stop 1

2,00 x 10⁻⁷ /h

Safety Integrity Level (SIL), Stop 0, suitable for applications in

3

Safety Integrity Level (SIL), Stop 1, suitable for applications in

2

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Mechanical data

Mechanical lifetime, minimum

10.000.000 Operations

Mounting

snäpps på standard-DIN-skena enligt EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Allowed type of cable

solid single-wire

flexible

Terminal (mechanical)

1000075113

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the installation space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +60 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

10 ... 55 Hz, amplitud 0,35 mm

Restistance to shock

10 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Operating voltage

24 VAC -15 % / +10 %
24 VDC -15 % / +20 %

Ripple voltage

10 %

Rated operating voltage

24 VAC

Rated operating voltage

24 VDC

Rated AC voltage for controls, 50 Hz, minimum

20.4 VAC

Rated control voltage at AC 50 Hz, maximum

26.4 VAC

Rated AC voltage for controls, 60 Hz, minimum

20.4 VAC

Rated control voltage at AC 60 Hz, maximum

26.4 VAC

Rated AC voltage for controls at DC minimum

20,4 VDC

Rated control voltage at DC, maximum

28,8 VDC

Electrical power consumption

3,2 W

Electrical power consumption

7,1 VA

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

i nyskick

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

30 ms

Drop-out delay in case of "emergency stop", maximum

36 ms

Pull-in delay at automatic start, maximum, typically

250 ms

Pull-in delay at RESET, typically

20 ms

Material of the contacts, electrical

AgSn0, AgNi, självrengörande, tvångsstyrd

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Positionsrelä K2

Positionsrelä K1

Intern driftspänning Ui

Positionsrelä K3

Other data

Note (applications)

Säkerhetssensor

Skyddsanordning

Nödstoppsknapp

Linnödstopp

Säkerhetsljusridå

Note

Note (General)

Induktiva laster (t.ex. kontaktorer, reläer etc.) måste dämpas med hjälp av en lämplig krets.

Wiring example

Note (Wiring diagram)

Kopplingsdiagrammet visas med skyddsdörrarna stängda och i strömlöst tillstånd.

Reläutgångar: Lämpliga för 2 kanalstyrning, för utökning av antalet kontakter med hjälp av kontaktorer eller reläer med positivt styrda kontakter.

Styrenheten identifierar kortslutning, kabelbrott och jordfel i övervakningskretsen.

Tvåkanalig övervakning för en skyddsdörr med två brytare varav minst en kontakt har tvångsbrytning, med extern reset (R).

(H2) = återkopplingskrets


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Alla data och värden har kontrollerats noga. Bilder kan avvika från originalet. Ytterligare tekniska data finns i manualen. Tekniska ändringar och fel förbehålles.

Genererat den 2025-08-18 08:39