schmersal_s_icon.png

SSW303HV

Artikelnummer: 103034847

Downloads

ePLAN Daten
CADENAS CAD-Daten
SISTEMA Daten
  • Standstill detection time 7s
  • Fail-safe standstill monitors
  • 3 safety contacts
  • 3 Signalling contacts
  • Sensor-free detection of standstill by monitoring e.m.f.
  • Direct connection to three-phase motors
  • Motor voltage range 0 ... 690 V

Ordering data

Product type description

SSW303HV

Article number (order number)

103034847

EAN (European Article Number)

4030661546421

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

IFA

cULus

CCC

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Kunststoff, glasfaserverstärkter Thermoplast

Gross weight

400 g

General data - Features

Wire breakage detection

Ja

Cross-circuit detection

Ja

Feedback circuit

Ja

Automatic reset function

Ja

Earth connection detection

Ja

Integral system diagnostics, status

Ja

Number of auxiliary contacts

3

Number of LEDs

5

Number of safety contacts

3

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Stop-Category

0

Safety classification - Relay outputs

Performance Level, stop 0, up to

e

Category, Stop 0

4

Diagnostic Coverage (DC) Level, Stop 0

≥ 99 %

PFH value, Stop 0

2,00 x 10⁻⁸ /h

Safety Integrity Level (SIL), Stop 0, suitable for applications in

3

Mechanical data

Mechanical life, minimum

10.000.000 Operations

Mounting

Schnellbefestigung für Normschiene nach DIN EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

starr oder flexibel

Schraubanschluss, steckbar

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

120 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +55 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

5 ... 9 Hz, Amplitude 3,5 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

8 kV

Rated impulse withstand voltage Uimp, relay output

6 kV

Degree of pollution

2

Electrical data

Operating voltage

24 VDC -10 % / +20 %

Ripple voltage

10 %

Type of voltage range

AC

Rated operating voltage

24 VDC

Rated operating voltage

24 ... 230 VAC

Rated AC voltage for controls, 50 Hz, minimum

21,6 VAC

Rated control voltage at AC 50 Hz, maximum

253 VAC

Rated AC voltage for controls, 60 Hz, minimum

21,6 VAC

Rated control voltage at AC 60 Hz, maximum

253 VAC

Electrical power consumption, maximum

4 W

Electrical power consumption, maximum

8,5 VA

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

in Neuzustand

Drop-out delay in case of "emergency stop", maximum

15 ms

Pull-in delay at automatic start (after detecting standstill), approx.

7.000 ms

Material of the contacts, electrical

AgSnO + Au, selbstreinigend, zwangsgeführt

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

6 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

6 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

6 A

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMV-Richtlinie

Status indication

Indicated operating states

OUT, Grün: Freigabe

Schaltzustand

UB: Versorgungsspannung vorhanden

ERR: Fehler Funktionsstörung

Other data

Note (applications)

Sichere Stillstandsüberwachung

Note

Note (General)

Induktive Verbraucher (Schütze, Relais etc.) sind durch eine geeignete Beschaltung zu entstören.


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.

Generiert am: 01.04.2025, 07:09