schmersal_s_icon.png

T4K 256-02Z-1297

Numéro d'article: 151120394

Téléchargements

TraceParts Données
ePLAN Données
CADENAS Données CAO
  • Mounting details to EN 50047
  • Thermoplastic enclosure
  • Double-insulated
  • 58 mm x 50,5 mm x 31 mm
  • Good resistance to oil and petroleum spirit
  • Wide range of alternative actuators
  • Actuator heads can be repositioned by 4 x 90°

Ordering data

Product type description

T4K 256-02Z-1297

Article number (order number)

151120394

eCl@ss number, version 12.0

27-27-26-01

eCl@ss number, version 11.0

27-27-26-01

eCl@ss number, version 9.0

27-27-26-01

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

Approvals - Standards

Certificates

cULus

CCC

General data

Standards

BG-GS-ET-15

EN ISO 13849-1

EN IEC 60947-5-1

Housing construction form

Construction normée

Housing material

Plastique, renforcé de fibres de verre

Gross weight

80 g

Safety classification

Vorschriften

EN ISO 13849-1

Mission time

20 Year(s)

Mechanical data

Actuating element

levier à galet inversé

Mechanical lifetime, minimum

20.000.000 Operations

Actuating force, minimum

6 N

Positive break force, minimum

16 N

Actuating speed, minimum

336 mm/min

Actuating speed, maximum

1 m/s

Note (Actuating speed)

Vitesse d'attaque pour un angle d'attaque vertical sur le poussoir de 30°

Mechanical data - Connection technique

Termination

Raccord fileté M20 x 1.5

Cable section, minimum

0,75 mm²

Cable section, maximum

2,5 mm²

Note

Toutes les indications relatives à la section du câble sont embouts compris.

Mechanical data - Dimensions

Length of sensor

31 mm

Width of sensor

58 mm

Height of sensor

94 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-30 ... +80 °C

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

6 kV

Electrical data

Thermal test current

10 A

Required rated short-circuit current

1.000 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching principle

contacts à action dépendante

Maximale Schalthäufigkeit

5.000 /h

Material of the contacts, electrical

Argent

Filtre de langue

Télécharger la dernière version d'Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.

Généré le: 20/08/2025 19:37