TL 461-22Y
TL 461-22Y
Téléchargements
- 2 cable entries M 20 x 1.5
- Metal enclosure
- 118 mm x 155 mm x 64 mm ( basic component)
- Actuator head can be repositioned in steps 4 x 90°
- Continuous adjustment of lever position 360°
- Lever can be transposed by 180°
- In temperature-resistant version, the roller can be mounted in two different positions on the shaft
Ordering data
Product type description |
TL 461-22Y |
Article number (order number) |
101059433 |
EAN (European Article Number) |
4030661254326 |
eCl@ss number, version 12.0 |
27-27-06-01 |
eCl@ss number, version 11.0 |
27-27-06-01 |
eCl@ss number, version 9.0 |
27-27-06-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
Certificates |
INMETRO |
General data
Standards |
EN IEC 60947-5-1 |
Working principle |
mécanique |
Slide form |
galet |
Housing material |
Fonte grise, galvanisée |
Housing coating material |
laquée |
Gross weight |
2405 g |
General data - Features
Number of normally closed (NC) |
2 |
Number of normally open (NO) |
2 |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
2000000 Operations |
Mechanical data
Actuating element |
tête rotatif à levier à galet |
Roller material |
Plastique |
Mechanical life, minimum |
10000000 Operations |
Actuating angle, from left of switch axis |
30 ° |
Actuating angle, from right of switch axis |
30 ° |
Contact opening |
max. 2 x 6 mm |
Actuating speed, minimum |
1 mm/min |
Actuating speed, maximum |
3 m/s |
Note (Actuating speed) |
Vitesse d'attaque pour un angle d'attaque vertical sur le poussoir |
Mechanical data - Connection technique
Termination |
Raccord fileté M20 x 1.5 |
Cable section, minimum |
1,5 mm² |
Cable section, maximum |
2,5 mm² |
Note |
Toutes les indications relatives à la section du câble sont embouts compris. |
Wire cross-section |
13 AWG |
Mechanical data - Dimensions
Length of sensor |
64 mm |
Width of sensor |
118 mm |
Height of sensor |
248 mm |
Width of Castor |
9 mm |
Diameter of Castor |
36 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-30 ... +90 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
400 V |
Rated impulse withstand voltage Uimp |
6 kV |
Electrical data
Thermal test current |
16 A |
Utilisation category AC-15 |
400 VAC |
Utilisation category AC-15 |
4 A |
Switching element |
Contact NO, contact NF |
Note (Switching element) |
avec double rupture |
Switching principle |
contacts à action dépendante |
Material of the contacts, electrical |
Argent |
Filtre de langue
Fiches techniques
Mode d'emploi et déclaration de conformité
Certificat DNV-GL
Télécharger la dernière version d'Adobe Reader
Photo du produit (photo individuelle de catalogue)
Photo du produit (photo individuelle de catalogue)
Plan d'encombrement composant de base
Plan d'encombrement actionneur
Diagramme des contacts
Principe de fonctionnement
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.
Généré le: 2025-04-29 18 h 54