SLC 430-E/R0460-30-RF-SYS
SLC 430-E/R0460-30-RF-SYS
Downloads
Codice: SLC 430-E/R(1)-30-RF-SYS |
(1) | |
0236 | Altezza del campo protettivo 236 mm |
0460 | Altezza del campo protettivo 460 mm |
0684 | Altezza del campo protettivo 684 mm |
0908 | Altezza del campo protettivo 908 mm |
1132 | Altezza del campo protettivo 1132 mm |
1356 | Altezza del campo protettivo 1356 mm |
1580 | Altezza del campo protettivo 1580 mm |
1804 | Altezza del campo protettivo 1804 mm |
- NOTICE: Not available!
- miniature body
- Safety type 4 in accordance with IEC 61496-1
- Resolution 30 mm
- Protection field height from 236 mm … 1804 mm
Ordering data
Note (Delivery capacity) |
Non più disponibile! |
Product type description |
SLC 430-E/R0460-30-RF-SYS |
Article number (order number) |
101207675 |
eCl@ss number, version 12.0 |
27-27-27-04 |
eCl@ss number, version 11.0 |
27-27-27-04 |
eCl@ss number, version 9.0 |
27-27-27-04 |
ETIM number, version 7.0 |
EC002549 |
ETIM number, version 6.0 |
EC002549 |
General data
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Housing material |
Alluminio |
Reaction time, maximum |
50 ms |
Gross weight |
1.400 g |
General data - Features
Restart interlock (manual reset) |
Sì |
Beam coding available |
Sì |
Integral system diagnostics, status |
Sì |
Integral system diagnostics |
Sì |
Number of safety contacts |
2 |
Number of beams |
16 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
1,26 x 10⁻⁸ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
30 mm |
Height of the protection field |
460 mm |
Range, protection field, minimum |
0,2 m |
Range, protection field, maximum |
3,5 m |
Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
Length of cable |
5 m |
Termination |
collegamento ad innesto |
Terminal connector, Recipient |
Cavo con connettore M8, 4 poli |
Terminal, Connector, Transmitter |
Cavo con connettore M8, 4 poli |
Length of the connectable cable, maximum |
100 m |
Mechanical data - Dimensions
Length of sensor |
20 mm |
Width of sensor |
12 mm |
Height of sensor |
692 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
+0 ... +50 °C |
Storage and transport temperature |
-10 ... +70 °C |
Protection class |
III |
Electrical data
Switching voltage OSSD, HIGH signal |
24 V |
Electrical power consumption of the receiver |
4 W |
Electrical power consumption of the transmitter |
4 W |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
4 A |
Design of control elements |
con commutazione p |
Scope of delivery
Scope of delivery |
trasmettitore + ricevitore, angolo di montaggio |
Accessory
Recommended safety switchgear |
NSR-0605 |
Note
Note (General) |
In caso di errore (Interruzione del cavo 0 V) fuoriesce una corrente massima di fuga di 1 mA. |
Filtro lingua
Scheda Tecnica
Manuale d'istruzioni e dichiarazione UE di conformità
Download dell'ultima versione di Adobe Reader
Immagine del prodotto (foto singola per catalogo)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.
Generato il 29/07/2025, 10:12