TK 461-30Y
TK 461-30Y
Downloads
- 2 cable entries M 20 x 1.5
- Metal enclosure
- 118 mm x 155 mm x 64 mm ( basic component)
- Actuator heads can be repositioned by 4 x 90°
Ordering data
Product type description |
TK 461-30Y |
Article number (order number) |
101059027 |
eCl@ss number, version 12.0 |
27-27-06-01 |
eCl@ss number, version 11.0 |
27-27-06-01 |
eCl@ss number, version 9.0 |
27-27-06-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
General data
Standards |
EN IEC 60947-5-1 |
Working principle |
meccanico |
Slide form |
Rullo |
Housing material |
Ghisa, zincato |
Housing coating material |
verniciato |
Gross weight |
1.990 g |
General data - Features
Number of normally open (NO) |
3 |
Safety classification - Safety outputs
B10D Normally-closed contact (NC) |
2.000.000 Operations |
Mechanical data
Actuating element |
Leva con rotella |
Roller material |
materiale sintetico |
Mechanical lifetime, minimum |
10.000.000 Operations |
Actuating angle, from left of switch axis |
45 ° |
Actuating angle, from right of switch axis |
30 ° |
Contact opening |
max. 2 x 6 mm |
Actuating speed, minimum |
1 mm/min |
Actuating speed, maximum |
0,5 m/s |
Note (Actuating speed) |
Velocità di azionamento con un angolo di avvicinamento |
Mechanical data - Connection technique
Termination |
Collegamento a vite M20 x 1.5 |
Cable section, minimum |
1,5 mm² |
Cable section, maximum |
2,5 mm² |
Note |
Tutte le indicazioni sulla sezione del cavo includono le bussole del conduttore. |
Wire cross-section |
13 AWG |
Mechanical data - Dimensions
Length of sensor |
64 mm |
Width of sensor |
118 mm |
Height of sensor |
229 mm |
Width of Castor |
6,5 mm |
Diameter of Castor |
25 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-30 ... +90 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
400 V |
Rated impulse withstand voltage Uimp |
6 kV |
Electrical data
Thermal test current |
16 A |
Utilisation category AC-15 |
400 VAC |
Utilisation category AC-15 |
4 A |
Switching element |
contatto di chiusura (NO) |
Note (Switching element) |
con doppia interruzione |
Switching principle |
Commutazione lenta |
Material of the contacts, electrical |
Argento |
Note
Note (General) |
Si dovrebbe evitare l'azionamento da destra, perchè in questo modo si riduce la durata meccanica dell'interruttore di posizione. |
Filtro lingua
Scheda Tecnica
Manuale d'istruzioni e dichiarazione UE di conformità
Download dell'ultima versione di Adobe Reader
Immagine del prodotto (foto singola per catalogo)
Immagine del prodotto (foto singola per catalogo)
Disegno quotato disp. di base
Disegno quotato azionatore
Diagramma della corsa di azionamento
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.
Generato il 11/08/2025, 09:48