SSW301HV-115V
SSW301HV-115V
Downloads
- Fail-safe standstill monitors
- This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning.
- 3 safety contacts, STOP 0
- Control category 4 to ISO 13849-1
Ordering data
Note (Delivery capacity) |
Ikke tilgjengelig! |
Product type description |
SSW301HV-115V |
Article number (order number) |
101182592 |
EAN (European Article Number) |
4250116202607 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus CCC |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Plast, glassfiber forsterket termoplast |
Gross weight |
500 g |
General data - Features
Wire breakage detection |
Ja |
Cross-circuit detection |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of auxiliary contacts |
1 |
Number of LEDs |
5 |
Number of safety contacts |
3 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mechanical data
Mechanical life, minimum |
10 000 000 Operations |
Mounting |
kneppes inn på standard DIN-skinne iht. EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
Stiv eller fleksibel Skrueforbindelse M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
90 mm |
Height |
83 mm |
Depth |
127 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, Amplitude 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Degree of pollution |
2 |
Electrical data
Operating voltage |
115 VAC -15 % / +10 % |
Rated operating voltage |
115 VAC |
Rated AC voltage for controls, 50 Hz, minimum |
97,8 VAC |
Rated control voltage at AC 50 Hz, maximum |
126,5 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
97,8 VAC |
Rated control voltage at AC 60 Hz, maximum |
126,5 VAC |
Electrical power consumption, maximum |
4 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
I ny tilstand |
Drop-out delay in case of "emergency stop", maximum |
15 ms |
Pull-in delay at automatic start (after detecting standstill), approx. |
7 000 ms |
Material of the contacts, electrical |
AgSn0 + Au, selvrensende, positiv handling |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
6 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
6 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Directive |
Status indication
Indicated operating states |
OUT, grønn: aktivering brytetilstand UB: Tilførselsspenning til stede ERR: Feil funksjonell defekt |
Other data
Note (applications) |
Trygg stillstandsovervåking |
Note
Note (General) |
Induktive belastninger (f.eks. kontaktorer, reléer, etc.) må undertrykkes ved hjelp av en egnet krets. |
Wiring example
Note (Wiring diagram) |
OUT: Aktiverende sikkerhetskontakter 13-14, 23-24 lukket |
Språk filter
Datablad
Bruksanvisning og konformitetserklæring
UL sertifikat
CCC-sertifisering
kablingseksempel (elektr. kabling)
Last ned den nyeste versjonen av Adobe Reader
Produktbilde (enkelt katalogbilde)
kablingseksempel
Symbol (teknisk standard)
103034847 SSW303HV
- Standstill detection time 7s
- Fail-safe standstill monitors
- 3 safety contacts
- 3 Signalling contacts
- Sensor-free detection of standstill by monitoring e.m.f.
- Direct connection to three-phase motors
- Motor voltage range 0 ... 690 V
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.
Generert til 22.04.2025, 11:42