AES 1136-2185
AES 1136-2185
- Monitoring of BNS range magnetic safety sensors
- 1 safety contact, STOP 0
- 2 Signalling outputs
Ordering data
Note (Delivery capacity) |
Niedostępne! |
Product type description |
AES 1136-2185 |
Article number (order number) |
101172221 |
EAN (European Article Number) |
4030661300450 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Notice |
Discontinued product |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
BG-GS-ET-14 BG-GS-ET-20 EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-3 BG-GS-ET-14 |
Housing material |
Tworzywo, Tworzywo termoplastyczne wzmocnione włóknem szklanym, obudowa wentylowana |
Gross weight |
190 g |
General data - Features
Wire breakage detection |
Tak |
Cross-circuit detection |
Tak |
Automatic reset function |
Tak |
Start-up test |
Tak |
Earth connection detection |
Tak |
Integral system diagnostics, status |
Tak |
Number of LEDs |
1 |
Number of normally closed (NC) |
2 |
Number of normally open (NO) |
1 |
Number of undelayed semi-conductor outputs with signaling function |
2 |
Number of safety contacts |
1 |
Number of signalling outputs |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, up to |
d |
Category |
3 |
PFH value |
1,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), suitable for applications in |
2 |
Mission time |
20 Year(s) |
Mechanical data
Mechanical lifetime, minimum |
20.000.000 Operations |
Mounting |
montaż na standardowej szynie DIN wg EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Allowed type of cable |
solid single-wire flexible |
Terminal (mechanical) |
1000075113 |
Mechanical data - Dimensions
Width |
22,5 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the installation space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
+0 ... +55 °C |
Storage and transport temperature |
-25 ... +70 °C |
Resistance to vibrations |
10...55 Hz, amplituda 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Thermal test current |
6 A |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Electrical power consumption |
5 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
w nowym stanie |
Drop-out delay in case of power failure, typically |
80 ms |
Drop-out delay in case of emergency, typically |
20 ms |
Pull-in delay at automatic start, maximum, typically |
100 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
Ag-Ni 10 pozłacane 0,2 µm |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
6 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
6 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Digital inputs
Input signal, HIGH Signal "1" |
10 … 30 VDC |
Input signal, LOW Signal "0" |
0 … 2 VDC |
Conduction resistance, maximum |
40 Ω |
Electrical data - Digital Output
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,1 A |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
Dyrektywa o kompatybilności elektromagnetycznej |
Integral system diagnosis (ISD)
Note (ISD -Faults) |
Następujące błędy zostały zarejestrowane przez moduły bezpieczeństwa i wskazane przez ISD. |
Faults |
Błąd załączenia lub wyłączenia przekaźnika bezpieczeństwa Niepowodzenie otwarcia lub zamknięcia kontaktów drzwiowych Monitorowanie zwarć międzykanałowych lub zwarcia połączeń wyłącznika Przerwanie połączeń wyłączników Niezadziałanie obwodów wejściowych lub obwodów przekaźnikowych sterowania modułu monitorującego bezpieczeństwa |
Other data
Note (applications) |
Czujnik bezpieczeństwa Osłony bezpieczeństwa |
Note
Note (General) |
Obciążenia indukcyjne (np. styczniki, przekaźniki itp.) należy wytłumić przy pomocy odpowiedniego obwodu. |
Wiring example
Note (Wiring diagram) |
Schemat okablowania dla zamknietej osłony bezpieczeńatwa i stanu z wyłączonym zasilaniem. Do zabezpieczenia osłony bezpieczeństwa, PL do d i Kategoria 3 Monitorowanie 1 osłony, wyposażonej w magnetyczny czujnik bezpieczeństwa typoszeregu BNS Jeżeli do przełączania obciążenia używany jest jeden lub dwa przekaźniki lub styczniki zewnętrzne, system może być sklasyfikowany jedynie w kategorii 3 wg EN ISO 13849-1, jeżeli wykluczenie błędu "awaria styczników zewnętrznych" może zostać udowodnione i udokumentowane, np. przez zastosowanie niezawodnych styczników o mniejszych wartościach znamionowych. Drugi stycznik prowadzi do zwiększenia bezpieczeństwa przez redundancję wyłączania obciążenia. Modyfikacja dla dwóch zestyków NC: Moduł bezpieczeństwa można zmodyfikować tak, aby monitorował dwa zestyki NC poprzez zmostkowanie przyłączy A1 i X1 Przy takiej konfiguracji detekcja zwarcia skrośnego przestaje działać. Przedłużenie opóźnienia aktywacji: Opóźnienie aktywacji może być zwiększane od 0,1 s do 1,0 s poprzez zmianę pozycji zworki umieszczonej pod pokrywą urządzenia. Tabele ISD (Zintegrowanego Systemu Diagnostyczego) dla analizy wskazań błędów i ich przyczyn zamieszczono w załączniku. |
Filtr językowy
Karta katalogowa
Instrukcja obsługi i deklaracja zgodności
Certyfikat UL
Info
Przykład połączeń (okablowanie elektryczne)
Biblioteka/Library SISTEMA-VDMA
pobierz najnowszą wersję Adobe Reader
Zdjęcie produktu (pojedyncze zdjęcie katalogowe)
Rysunek wymiarowy Urządzenie podstawowe
Przykład okablowania
Przykład okablowania
103009970 SRB-E-201LC
- Plug-in screw terminals with coding
- STOP 0 Function
- 1 oder 2-channel control
- Start button / Auto-start
- 2 Safety outputs 2 A
- 1 Signalling output
103007672 SRB-E-301ST
- Plug-in screw terminals with coding
- STOP 0 Function
- 1 oder 2-channel control
- Start button / Auto-start
- 1 Auxiliary contact
- 3 safety contacts
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Dane zostały starannie sprawdzone. Zdjęcia mogą odbiegać od rzeczywistości. Dalsze dane techniczne znajdują się w instrukcji obsługi. Możliwe są zmiany i błędy techniczne.
Wygenerowano dnia 17.08.2025, 15:56