T2C 470-33Y
T2C 470-33Y
Descargas
- 4 cable entries M 20 x 1.5
- Metal enclosure
- 6 Contacts
- 130 mm x 194 mm x 64 mm ( basic component)
- With latching end position
- Actuator heads can be repositioned by 4 x 90°
- Change in actuating direction by repositioning actuator head
- Case-hardened lever
Ordering data
Product type description |
T2C 470-33Y |
Article number (order number) |
101059736 |
EAN (European Article Number) |
4030661037271 |
eCl@ss number, version 12.0 |
27-27-06-01 |
eCl@ss number, version 11.0 |
27-27-06-01 |
eCl@ss number, version 9.0 |
27-27-06-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
Certificates |
INMETRO |
General data
Standards |
EN IEC 60947-5-1 |
Working principle |
mecânico |
Housing material |
Ferro fundido cinzento, galvanizado |
Housing coating material |
pintura de fábrica |
Gross weight |
2 865 g |
General data - Features
Number of normally closed (NC) |
3 |
Number of normally open (NO) |
3 |
Mechanical data
Actuating element |
Alavanca de forquilha |
Mechanical life, minimum |
10 000 000 Operations |
Contact opening |
máx. 2 x 6 mm |
Actuating speed, minimum |
1 mm/min |
Actuating speed, maximum |
0,5 m/s |
Note (Actuating speed) |
Velocidade de condução com um ângulo de aproximação |
Mechanical data - Connection technique
Termination |
Ligação por parafuso M20 x 1.5 |
Cable section, minimum |
1,5 mm² |
Cable section, maximum |
2,5 mm² |
Note |
Todas as especificações incluindo ponteiras de cabo. |
Wire cross-section |
13 AWG |
Mechanical data - Dimensions
Length of sensor |
64 mm |
Width of sensor |
130 mm |
Height of sensor |
289 mm |
Ambient conditions
Degree of protection |
IP65 |
Ambient temperature |
-30 ... +90 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
400 V |
Electrical data
Thermal test current |
16 A |
Utilisation category AC-15 |
400 VAC |
Utilisation category AC-15 |
4 A |
Switching element |
Contacto normalmente fechado/contacto normalmente aberto (NA/NO) |
Note (Switching element) |
com interrupção dupla |
Switching principle |
Comutação lenta |
Material of the contacts, electrical |
Prata |
Filtro de idioma
Ficha técnica
Manual de instruções e Declaração de conformidade
Certificação DNV-GL
Faça download da versão mais recente do Adobe Reader
Foto do produto (foto individual do catálogo )
Desenho dimensional componente básico
Desenho dimensional Atuador
Princípio operacional
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Os dados e informações anteriores foram verificados cuidadosamente. As imagens podem ser diferentes do original. Mais informações técnicas podem ser encontradas nos manuais de instruções. Sujeito a modificações técnicas e erros.
Gerado em 01/06/2025 19:31