schmersal_s_icon.png

IFOD 8-300-10/01

Artikelnummer: 103038715

Downloads

TracePart CAD Data
ePLAN Data
CADENAS CAD Data
SISTEMA Data
Produktbeteckning:
IFOD (1)-(2)-(3)(4)

(1)
8Aktiveringsavstånd 800 mm
10Aktiveringsavstånd 1000 mm

(2)
30cylinder, gänga M30, metall
300Cylinder, gänga M30, plast

(3)
01Öppnare (NC)
10Slutande kontakt (sl)
10/01Slutande kontakt (sl) / brytande kontakt (br) med anslutningsutrymme
11Slutande kontakt (sl) / brytande kontakt (br) antivalent

(4)
utanStyrutgångens utförande tvåtråd
Ppnp
Det är möjligt att alla möjliga enheter enligt denna typnyckel inte går att leverera och/eller inte tekniskt realiserbara.
  • Thermoplastic enclosure
  • AC 2-wire
  • Wiring compartment can be turned 180°
  • Design M30
  • Wiring compartment

Ordering data

Product type description

IFOD 8-300-10/01

Article number (order number)

103038715

EAN (European Article Number)

4030661545967

eCl@ss number, version 12.0

27-27-09-03

eCl@ss number, version 11.0

27-27-09-03

eCl@ss number, version 9.0

27-27-09-03

ETIM number, version 7.0

EC001821

ETIM number, version 6.0

EC001821

General data

Standards

DIN VDE 0660-208

EN IEC 60947-5-2

Housing construction form

cylinder, gänga

Housing material

Plast

Active area

Plast

Material of the nuts

Plast

Material of the washer

Perbunan®

Detection range Sd, maximum

800 mm

Gross weight

72 g

General data - Features

Integral system diagnostics, status

Ja

Number of cable wires

2

Mechanical data

Tightening torque of nuts, maximum

4 Nm

Mechanical data - Connection technique

Termination

Skruvkoppling

Cable section, maximum

2 x 1,5 mm²

Wire cross-section

15 AWG

Mechanical data - Dimensions

ISO thread of the sensor

M30

width across flats

36 BK

Length of sensor

118 mm

Width of sensor

46 mm

Height of sensor

46 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature

-5 ... +70 °C

Protection class

II

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

10 kV

Electrical data

Rated supply frequency, minimum

45 Hz

Rated supply frequency, maximum

65 Hz

Type of voltage range

DC

Operating current, minimum

10 mA

Rated operating voltage

15 ... 250 VAC

Operating current

500 mA

Switching element

NO eller NC

Protection circuit integrated

induktivt störningsskydd

Switching frequency, approx.

10 Hz

Electrical data - Digital Output

Voltage drop Ud, maximum

7 V

Current at Voltage drop Ud

0,5 A

Design of control elements

Två ledningar

Current leakage Ir, maximum

3 mA

Status indication

Note (Integral System Diagnostics, status )

gul LED


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Alla data och värden har kontrollerats noga. Bilder kan avvika från originalet. Ytterligare tekniska data finns i manualen. Tekniska ändringar och fel förbehålles.

Genererat den 2025-04-25 06:05