EX-SHGV/ESS21S2/217/11033-3G/D
EX-SHGV/ESS21S2/217/11033-3G/D
Downloads
- Key-operated selector switch
- Explosion protection for ATEX Zones 2 and 22
- Metal enclosure
Ordering data
Product type description |
EX-SHGV/ESS21S2/217/11033-3G/D |
Article number (order number) |
101198792 |
EAN (European Article Number) |
4030661590332 |
eCl@ss number, version 12.0 |
27-37-12-43 |
eCl@ss number, version 11.0 |
27-37-12-43 |
eCl@ss number, version 9.0 |
27-37-12-43 |
ETIM number, version 7.0 |
EC001029 |
ETIM number, version 6.0 |
EC001029 |
Approvals - Standards
Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN 60079-11 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection designation |
D II 3D Ex tc IIIC T110°C Dc X D II 3G Ex ic IIC T5 Gc X |
General data
Standards |
EN ISO 14119 |
Versions |
Tuş - selektör - ön plaka montajı |
Installation conditions (mechanical) |
gelişigüzel |
Sealing type |
Membranlar Dudaklı contalar |
Housing material |
Plastik, fiber cam takviyeli termoplastik kendiliğinden söner |
Material of the cylinder lock |
Çelik |
Material of the front ring |
Aluminyum |
Colour of the cylinder lock |
AgCdO, kendi kendini temizler, pozitif hareket |
Colour of the Contact element |
Siyah |
Colour of the front ring |
AgCdO, kendi kendini temizler, pozitif hareket |
Colour of key head |
AgCdO, kendi kendini temizler, pozitif hareket |
Gross weight |
136 g |
General data - Features
Latching |
Evet |
Fully insulated |
Evet |
Number of plunger |
1 |
Number of switch positions |
2 |
Mechanical data
Unlocking |
Döner kilit açıcı |
Key withdrawal position |
Konum I 90° |
Latching position |
sağ |
Mechanical life, minimum |
100.000 Operations |
Impact energy, maximum |
4 J |
Mounting |
Montaj flanşı |
Tightening torque of the screw |
0,6 Nm |
Key number |
217 |
Mechanical data - Connection technique
Termination |
Vida bağlantısı M20 x 1.5 |
Cable section, minimum |
0.5 mm², sağlam 0.5 mm², esnek |
Cable section, maximum |
2 x 1,5 mm² 2.5 mm², sağlam 2.5 mm², esnek |
Tightening torque of Clips |
1 Nm |
Mechanical data - Dimensions
Length x Width x Height |
Yükseklik ile tuş (ve kontakt elemanı): 60 mm (119 mm) |
Diameter of the front ring |
29,5 mm |
diameters for the cylinder lock |
22 mm |
Mounting diameter |
22,3 mm |
Thickness, of the front panel, minimum |
1 mm |
Thickness of the front panel, maximum |
6 mm |
Spacing |
40 x 50 mm |
Ambient conditions
Degree of protection |
IP65 |
Degree of protection of the switch rooms |
IP40 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
+0 ... +75 °C |
Restistance to shock |
110 g / 4 ms |
Resistant to vibration |
Karşı son derece dirençli : 20 g / 10…200 Hz |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
400 V |
Electrical data
Thermal test current |
10 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
8 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
5 A |
Suitable for low-voltages |
≥ 5 V / ≥ 3,2 mA |
Switching element |
Normalde kapalı kontakt (NC) / Normalde açık kontakt (NO) |
Switching principle |
Yavaş hareket |
Bounce duration, maximum |
5 ms |
Maximale Schalthäufigkeit |
5 /h |
Material of the contacts, electrical |
AgCdO, kendi kendini temizler, pozitif hareket |
Dil filtresi
Veri sayfası
Çalışma Talimatları ile Uygunluk beyanı
Adobe Reader’ın son sürümünü indirin
Ürün resmi (katalog özel fotoğraf)
ID: kxshgvf10
| 332,6 kB | .jpg | 352.425 x 528.814 mm - 999 x 1499 px - 72 dpi
| 57,5 kB | .png | 73.731 x 110.772 mm - 209 x 314 px - 72 dpi
| 29,8 kB | .jpg | 82.197 x 123.472 mm - 233 x 350 px - 72 dpi
| 314,8 kB | .jpg | 352.425 x 528.814 mm - 999 x 1499 px - 72 dpi
| 55,4 kB | .png | 73.731 x 110.772 mm - 209 x 314 px - 72 dpi
| 55,4 kB | .png | 73.731 x 110.772 mm - 209 x 314 px - 72 dpi
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name and designation of the component: | EX-SHGV | D II 2GD Ex h 85°C X |
EX-SHGV/ESS | D II 3G Ex ic IIC T5 Gc X D II 3D Ex tc IIIC T110°C Dc X | |
EX-SVE | D II 3D Ex tc IIIC T85°C Dc X |
Type: | See ordering code |
Description of the component: | Interlocking device with electromagnetic interlock for safety functions |
Relevant Directives: | Machinery Directive | 2006/42/EC |
Explosion Protection Directive (ATEX) | 2014/34/EU | |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 ISO 14119:2014 ISO 13849-1:2015 EN IEC 60079-0:2018 EN 60079-11:2012 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Notified body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
EC-Type Examination Certificate: | 01/205/5754.00/20 |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a test center. |
Place and date of issue: | Wuppertal, January 23, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | EX-SHGV | D II 2GD Ex h 85°C X |
EX-SHGV/ESS | D II 3G Ex ic IIC T5 Gc X D II 3D Ex tc IIIC T110°C Dc X | |
EX-SVE | D II 3D Ex tc IIIC T85°C Dc X |
Type: | See ordering code |
Description of the component: | Interlocking device with electromagnetic interlock for safety functions |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-1:2017 ISO 14119:2014 ISO 13849-1:2015 EN IEC 60079-0:2018 EN 60079-11:2012 EN 60079-31:2014 EN ISO 80079-36:2016 EN ISO 80079-37:2016 |
Approved body for Type Examination: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln ID n°: 0035 |
Type examination certificate: | 01/205/5754.00/20 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a conformity assessment center. |
Place and date of issue: | Wuppertal, March 7, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Veriler ve ayrıntılar dikkatli bir şekilde kontrol edilmişlerdir. Görüntüler orijinalden farklı olabilir. Daha fazla teknik veri kılavuzda bulunabilir. Teknik değişiklikler ve hatalar olabilir.
Udarbejdet d. 12.04.2025 19:37