EX-T4K 235-20ZH-3D
产品描述: EX-(1)(2) 235-(3)Z-(4)-(5)-(6)-(7)-3D |
(1) | |
Z | 速动 |
T | 缓动 (不适用于AF/S) |
(2) | |
S | 直杆 S |
R | 滚轮直杆 R |
4S | 直杆 4S |
4R | 滚轮直杆 4R |
1R | 偏置滚轮摇臂 1R |
K | 偏置滚轮摇臂 K |
3K | 角度滚轮摇臂 3K |
4K | 角度滚轮摇臂 4K |
K4 | 角度滚轮摇臂 K4 |
1H | 滚轮摇臂 1H |
7H | 滚轮摇臂 7H |
10H | 棒杆 10H |
12H | 滚轮摇臂 12H |
14H | 滚轮摇臂 14H |
(3) | |
02 | 2 NC 触点 |
11 | 1 NO 触点/1 NC 触点 |
20 | 2 NO触点(带2个NO触点的开关不适用于安全操作) |
(4) | |
H | 缓动带非同步触头 |
UE | 缓动带交错触头 |
(5) | |
1297 | 带横槽孔的外壳 |
(6) | |
2138 | 滚轮摇臂7H,用于带安全功能的限位开关 |
(7) | |
1637 | 镀金触头 |
- Metal enclosure
- Wide range of alternative actuators
- Good resistance to oil and petroleum spirit
- 30 mm x 63,5 mm x 30 mm
- Actuator heads can be repositioned by 4 x 90°
- Mounting details to EN 50047
- 1 Cable entry M 20 x 1.5
- Actuation from bottom parallel to the switch, therefore only suitable for small housings.
Ordering data
Product type description |
EX-T4K 235-20ZH-3D |
Article number (order number) |
101213281 |
EAN (European Article Number) |
4030661395777 |
eCl@ss number, version 12.0 |
27-27-06-01 |
eCl@ss number, version 11.0 |
27-27-06-01 |
eCl@ss number, version 9.0 |
27-27-06-01 |
ETIM number, version 7.0 |
EC000030 |
ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
Certificates |
ATEX (Konformitätserklärung) |
Explosion protection
Explosion protection: regulations |
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31 |
Explosion protection zones |
2 22 |
Explosion protection category |
3G 3D |
Explosion protection designation |
D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
Manufacturer declaration |
ATEX 2区和22区 |
General data
Standards |
BG-GS-ET-15 EN IEC 60947-5-1 |
Housing construction form |
标准结构设计 |
Housing material |
金属,压铸锌 |
Housing coating material |
涂色 |
Gross weight |
215 g |
General data - Features
Number of auxiliary contacts |
2 |
Safety classification |
Vorschriften |
EN ISO 13849-1 |
Mission time |
20 Year(s) |
Mechanical data
Actuating element |
斜角推杆 |
Mechanical lifetime, minimum |
20,000,000 Operations |
Actuating force, minimum |
6 N |
Positive break force, minimum |
16 N |
Actuating speed, minimum |
264 mm/min |
Actuating speed, maximum |
1 m/s |
Note (Actuating speed) |
操作角度30°至开关轴的操动速度 |
Note Bounce duration |
符合操动速度的回弹时间 |
Note (Switchover time) |
符合操动速度的切换时间 |
Mechanical data - Connection technique
Termination |
螺丝端子 M20 x 1.5 |
Cable cross-section of the cable glands, minimum |
7 mm |
Cable cross-section of the cable glands, maximum |
12 mm |
Cable section, minimum |
.75 mm² |
Cable section, maximum |
2.5 mm² |
Note |
包括导体套管在内的所有指标。 |
Wire cross-section |
13 AWG |
Mechanical data - Dimensions
Length of sensor |
30 mm |
Width of sensor |
42 mm |
Height of sensor |
107 mm |
Ambient conditions
Degree of protection |
IP67 |
Ambient temperature |
-20 ... +60 °C |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
500 V |
Rated impulse withstand voltage Uimp |
6 kV |
Electrical data
Thermal test current |
10 A |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
4 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1 A |
Switching element |
常开触点(NO) |
Switching principle |
非同步触点 |
Maximale Schalthäufigkeit |
5,000 /h |
Material of the contacts, electrical |
银 |
Scope of delivery
Scope of delivery |
防爆螺纹电缆密封套 |
语言条件
数据表
操作指南及符合性声明
SISTEMA-VDMA 数据库
下载最新版本的Adobe Reader
产品图片(单独目录照片)
尺寸图 基本组件
尺寸图 基本组件
尺寸图 操动件
开关行程图
EU Declaration of Conformity | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
Name of the component: | EX-Z/T 235 |
Type: | See ordering code |
Marking: | D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
Description of the component: | Positive break position switch |
Relevant Directives: | Explosion Protection Directive (ATEX) | 2014/34/EU |
RoHS-Directive | 2011/65/EU |
Applied standards: | EN 60947-5-1:2017 + AC:2020 EN IEC 60079-0:2018 EN IEC 60079-15:2019 EN 60079-31:2014 |
Conformity with the explosion protection directive 2014/34/EU (ATEX) is declared by the manufacturer without involving a conformity assessment center. |
Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Place and date of issue: | Wuppertal, September 7, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。
生成日期 2025/8/28 上午2:27