  • Pre-wired cable 7-pole
  • Comfortable diagnostics through sensor LED and electronic signalling output
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Ø M18
  • Misaligned actuation possible
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • Early warning when operating near the limit of the sensor's hysteris range
  • Self-monitoring series-wiring of 16 sensors
  • 2 short-circuit proof PNP safety outputs
  • Explosion protection for ATEX Zones 2 and 22

Ordering data

Product type description

EX-CSS 8-180-2P+D-M-L-3G/D

Article number (order number)

101189302

EAN (European Article Number)

4030661347158

eCl@ss number, version 12.0

27-27-46-01

eCl@ss number, version 11.0

27-27-24-03

eCl@ss number, version 9.0

27-27-24-03

ETIM number, version 7.0

EC001829

ETIM number, version 6.0

EC001829

Approvals - Standards

Certificates

TÜV

UKCA

ATEX (Konformitätserklärung)

Explosion protection

Explosion protection: regulations

EN IEC 60079-0

EN IEC 60079-15

EN 60079-31

Explosion protection zones

2

22

Explosion protection category

3G

3D

Explosion protection designation

D II 3G Ex nA IIB T6 Gc X

D II 3G Ex nA IIC T6 Gc X

D II 3D Ex tc IIIC T70°C Dc X

Manufacturer declaration

ATEX 2区和22区

General data

Working principle

感应

Housing construction form

圆柱、螺纹

Installation conditions (mechanical)

非冲洗

Sensor topology

串联传感器

Housing material

玻璃纤维,加强型热塑塑料

Active area

玻璃纤维,加强型热塑塑料

Material of the nuts

玻璃纤维,加强型热塑塑料

Reaction time, maximum

30 ms

Duration of risk, maximum

30 ms

Gross weight

135 g

General data - Features

Short circuit detection

Cross-circuit detection

Safety functions

Integral system diagnostics, status

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

16

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 61508

Performance Level, up to

e

Category

4

PFH value

2.50 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Impact energy, maximum

2 J

Tightening torque of nuts, maximum

3 Nm

Mechanical data - Switching distances

Switch distance, typical

8 mm

Assured switching distance "ON" Sao

7 mm

Assured switching distance "OFF" Sar

10 mm

Note (switching distance)

All switching distances in accordance EN IEC 60947-5-3

Hysteresis (Switching distance), maximum

0.7 mm

Repeat accuracy R

0.2 mm

Mechanical data - Connection technique

Length of cable

2 m

Termination

电缆

Terminal connector, Output

7针

Number of cable wires

7

Wire cross-section

0.25 mm2

Wire cross-section

23 AWG

Mechanical data - Dimensions

ISO thread of the sensor

M18

width across flats

24 BK

Length of sensor

92 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature

-25 ... +40 °C

Storage and transport temperature

-25 ... +85 °C

Resistance to vibrations

10 ... 55 Hz,振幅 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

No-load supply current I0, typical

50 mA

Rated operating voltage

24 VDC

Operating current

1,000 mA

Switching frequency, approx.

3 Hz

Utilisation category DC-12

24 VDC / 0.05 A

Electrical data - Safety digital outputs

Design of control elements

P型

Voltage drop Ud, maximum

0.5 V

Leakage current Ir, maximum

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.5 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.5 A

Electrical data - Digital Output

Design of control elements

P型

Electrical data - Diagnostic outputs

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Status indication

Note (LED switching conditions display)

多色发LED:绿色,红色,黄色

Pin assignment

PIN 1

A1 Ue 棕色

PIN 2

Y2 安全输出 2 红色

PIN 3

A2 GND 蓝

PIN 4

Y1 安全输出 1 黑色

PIN 5

X1 安全输入 1 紫色

PIN 6

X2 安全输入 2 白

PIN 7

信号输出 灰色

Scope of delivery

Scope of delivery

操动件#必须单独订购.

Scope of delivery of mounting material

2x 螺母 M18 x 1

Accessory

Recommendation (actuator)

CST 180-1

CST 180-2

Note

Note (General)

传感器的串联接线:可以串联16个安全传感器,自监控 在这种情况下,传感器的双通道输出切换到/插入到下一个传感器的输入中。根据EN ISO 13849-1,这不会影响类别4。

在计划电缆路径时,必须考虑到长距离传感器链的电压降问题。工作电压、电缆的截面和长度、温度、连接的传感器数量以及控制监控器的输入负载都会影响传感器链上的电压降。

语言条件

接线图示(电线)

下载最新版本的Adobe Reader

UK Declaration of Conformity LOG_COM_lo1de01s
Company:K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom.
Name of the component:EX-CSS 8-180
Type:See ordering code
Marking:D II 3G Ex nA IIC T6 Gc X
D II 3D Ex tc IIIC T70°C Dc X
Description of the component:Non-contact safety sensor
Relevant legislation:Supply of Machinery (Safety) Regulations2008
 Electromagnetic Compatibility Regulations2016
 Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres Regulations2016
 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations2012
Designated standards:EN 60947-5-3:2013,
EN ISO 14119:2013,
EN ISO 13849-1:2015,
EN 61508 parts 1-7:2010,
EN IEC 60079-0:2018,
EN IEC 60079-15:2019,
EN 60079-31:2014
Approved body for Type Examination:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Type examination certificate:01/205/5874.00/21
The conformity assessment procedure for explosion protection was carried out in accordance with Article 13 of Directive 2014/34/EU, under the responsibility of the manufacturer K.A. Schmersal GmbH & Co. KG.
UK-Importer /
Person authorised for the compilation of the technical documentation:



Schmersal UK Ltd.
Paul Kenney
Unit 1, Sparrowhawk Close
Enigma Business Park
Malvern, Worcestershire, WR14 1GL
Place and date of issue:Wuppertal, August 12, 2022
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director
EU Declaration of Conformity LOG_COM_lo1de01s
Original



K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Declaration:We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component:EX-CSS 180
Type:See ordering code
Marking:D II 3G Ex nA IIC T6 Gc X
 D II 3D Ex tc IIIC T70°C Dc X
Description of the component:Non-contact safety sensor
Relevant Directives:Machinery Directive2006/42/EC
 EMC-Directive2014/30/EU
 Explosion Protection Directive (ATEX)2014/34/EU
 RoHS-Directive2011/65/EU
Applied standards:DIN EN 60947-5-3:2014
EN 60079-0:2012 + A11:2013
EN 60079-15:2010
EN 60079-31:2014
Notified body, which approved the full quality assurance system, referred to Appendix IV, 2014/34/EU:TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
Person authorised for the compilation of the technical documentation:Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue:Wuppertal, May 2, 2017
 GRA_SIG_ksig-y24
 Authorised signature
Philip Schmersal
Managing Director

Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。

生成日期 2025/7/27 下午3:02