SRB324LT 24V
- Optional: Short-circuit recognition, Manual reset with edge detection in fail-safe circuit, Automatic reset function
- Suitable for the signal processing of outputs with contact sensors
- Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
- 3 safety contacts, STOP 0;
2 safety contacts, STOP 1 (adjustable 1 … 30 s) - 3 Signalling outputs, 1 Auxiliary contact
Ordering data
Note (Delivery capacity) |
不支持! |
Product type description |
SRB324LT 24V |
Article number (order number) |
101204855 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
TÜV cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
玻璃纤维加固热塑塑料,带通风 |
Gross weight |
480 g |
General data - Features
Electronic Fuse |
是 |
Wire breakage detection |
是 |
Cross-circuit detection |
是 |
Removable Terminals |
是 |
Start input |
是 |
Feedback circuit |
是 |
Automatic reset function |
是 |
Reset edge detection |
是 |
Earth connection detection |
是 |
Integral system diagnostics, status |
是 |
Number of auxiliary contacts |
1 |
Number of LEDs |
6 |
Number of normally closed (NC) |
2 |
Number of undelayed semi-conductor outputs with signaling function |
3 |
Number of safety contacts |
5 |
Number of signalling outputs |
3 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 1 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Performance Level, stop 1, up to |
d |
Category, Stop 0 |
4 |
Category, Stop 1 |
3 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
Diagnostic Coverage (DC) Level, Stop 1 |
> 60 |
PFH value, Stop 0 |
2.00 x 10⁻⁸ /h |
PFH value, Stop 1 |
2.00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Safety Integrity Level (SIL), Stop 1, suitable for applications in |
2 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanical data
Mechanical life, minimum |
10,000,000 Operations |
Mounting |
DIN导轨快速安装,依据EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
硬线或软线 螺丝端子 M20 x 1.5 |
Cable section, minimum |
.25 mm² |
Cable section, maximum |
2.5 mm² |
Tightening torque of Clips |
0.6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +60 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, 振幅 .35 mm |
Restistance to shock |
10 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls, 50 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls at DC minimum |
20.4 VDC |
Rated control voltage at DC, maximum |
28.8 VDC |
Electrical power consumption |
3.2 W |
Electrical power consumption |
7.1 VA |
Contact resistance, maximum |
0.1 Ω |
Note (Contact resistance) |
处于全新的状态 |
Drop-out delay in case of power failure, typically |
80 ms |
Drop-out delay in case of emergency, typically |
30 ms |
Drop-out delay in case of "emergency stop", maximum |
36 ms |
Pull-in delay at automatic start, maximum, typically |
250 ms |
Pull-in delay at RESET, typically |
20 ms |
Material of the contacts, electrical |
氧化锡银,银镍,自清洁,强制定位 |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC指令 |
Status indication
Indicated operating states |
位置继电器 K2 位置继电器 K1 内部工作电压 Ui 位置继电器 K3 |
Other data
Note (applications) |
安全传感器 防护系统 紧急停止按钮 紧急停止拉绳开关 安全光幕 |
Note
Note (General) |
感应负载(例如接触器、继电器等)必须通过适当的电路抑制。 |
Wiring example
Note (Wiring diagram) |
接线图显示的是防护门关闭且处于断电状态的情况。 继电器输出:适用于双通道控制,用于增强触点容量或增加触点数量,通过使用接触器或带强制定位触点的继电器。 控制器可以识别监控电路中的交叉短路、电缆断裂和接地泄漏。 展示了防护门监控用的带两个触点的双通道控制,其中至少一个触点肯定断开,带外部复位按钮(R)。 (H2)= 反馈电路 |
语言条件
数据表
操作指南及符合性声明
UL证书
下载最新版本的Adobe Reader
产品图片(单独目录照片)
接线图示
工作原理
符号(技术标准)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。
生成日期 2025/4/16 上午4:01