SLC 420-E/R0250-30-69-RFB
SLC 420-E/R0250-30-69-RFB
- Schutzart IP69K
- Sicherheitstyp 4 gemäß IEC 61496-1
- Auflösung 14 mm und 30 mm
- Schutzfeldhöhe von 170 mm … 1450 mm
Bestelldaten
Note (Delivery capacity) |
Nicht mehr lieferbar! |
Product type description |
SLC 420-E/R0250-30-69-RFB |
Article number (order number) |
101206953 |
eCl@ss number, version 12.0 |
27-27-27-04 |
eCl@ss number, version 11.0 |
27-27-27-04 |
eCl@ss number, version 9.0 |
27-27-27-04 |
ETIM number, version 7.0 |
EC002549 |
ETIM number, version 6.0 |
EC002549 |
Zulassungen - Vorschriften
Certificates |
TÜV cULus |
Allgemeine Daten
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Housing material |
Aluminium |
Reaction time, maximum |
10 ms |
Gross weight |
2.550 g |
Allgemeine Daten - Eigenschaften
Restart interlock (manual reset) |
Ja |
Beam coding available |
Ja |
Blanking function |
Ja |
Integral system diagnostics, status |
Ja |
Integral system diagnostics |
Ja |
Number of fail-safe digital outputs |
2 |
Number of beams |
12 |
Sicherheitsbetrachtung
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
6,19 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
4 |
Mechanische Daten
Detection ability for test bodies at v = 1.6 m/s |
30 mm |
Height of the protection field |
250 mm |
Range, protection field, minimum |
0,3 m |
Range, protection field, maximum |
10 m |
Wave length of the laserdiode |
880 nm |
Mechanische Daten - Anschlusstechnik
Length of cable |
5 m |
Termination |
Steckverbinder |
Terminal connector, Recipient |
Leitung mit Stecker M12, 8-polig |
Terminal, Connector, Transmitter |
Leitung mit Stecker M12, 4-polig |
Length of the connectable cable, maximum |
100 m |
Mechanische Daten - Abmessungen
Diameter of sensor |
60 mm |
Height of sensor |
347 mm |
Umgebungsbedingungen
Degree of protection |
IP69K |
Ambient temperature |
-10 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Protection class |
III |
Elektrische Daten
Switching voltage OSSD, HIGH signal |
24 V |
Electrical power consumption of the receiver |
8 W |
Electrical power consumption of the transmitter |
4 W |
Elektrische Daten - Sichere digitale Ausgänge
Output current, (fail-safe output), maximum |
0,5 A |
Design of control elements |
p-schaltend |
Lieferumfang
Scope of delivery |
Sender + Empfänger, Befestigungsset |
Zubehör
Recommended safety switchgear |
SRB-E 301 |
Hinweis
Note (General) |
Im Fehlerfall (Unterbrechung der 0 V Leitung) fließt ein max. Leckstrom von 1 mA. |
Sprachfilter
Datenblatt
Montage- und Anschlussanleitung
Betriebsanleitung und Konformitätserklärung
Baumusterprüfbescheinigung
UL-Zertifikat
Broschüre
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Maßzeichnung Grundgerät
Polbild
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 03.05.2025, 01:00