SLC 420-E/R0250-30-69-RFB
SLC 420-E/R0250-30-69-RFB
- Protection class IP69K
- Safety type 4 in accordance with IEC 61496-1
- Resolution 14 mm and 30 mm
- Protection field height from 170 mm … 1450 mm
Ordering data
Note (Delivery capacity) |
Not available! |
Product type description |
SLC 420-E/R0250-30-69-RFB |
Article number (order number) |
101206953 |
eCl@ss number, version 12.0 |
27-27-27-04 |
eCl@ss number, version 11.0 |
27-27-27-04 |
eCl@ss number, version 9.0 |
27-27-27-04 |
ETIM number, version 7.0 |
EC002549 |
ETIM number, version 6.0 |
EC002549 |
Approvals - Standards
|
TÜV cULus |
General data
Standards |
EN IEC 61496-2 EN IEC 61496-1 |
Housing material |
Aluminium |
Reaction time, maximum |
10 ms |
Gross weight |
2,550 g |
General data - Features
Restart interlock (manual reset) |
Yes |
Beam coding available |
Yes |
Blanking function |
Yes |
Integral system diagnostics, status |
Yes |
Integral system diagnostics |
Yes |
Number of fail-safe digital outputs |
2 |
Number of beams |
12 |
Safety classification |
Standards |
EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
6.19 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Safety type in accordance with IEC 61496-1 |
4 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s |
30 mm |
Height of the protection field |
250 mm |
Range, protection field, minimum |
0.3 m |
Range, protection field, maximum |
10 m |
Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
Length of cable |
5 m |
Termination |
Connector |
Terminal connector, Recipient |
Cable with connector plug M12, 8-pole |
Terminal, Connector, Transmitter |
Cable with connector plug M12, 4-pole |
Length of the connectable cable, maximum |
100 m |
Mechanical data - Dimensions
Diameter of sensor |
60 mm |
Height of sensor |
347 mm |
Ambient conditions
Degree of protection |
IP69K |
Ambient temperature |
-10 ... +50 °C |
Storage and transport temperature |
-25 ... +70 °C |
Protection class |
III |
Electrical data
Switching voltage OSSD, HIGH signal |
24 V |
Electrical power consumption of the receiver |
8 W |
Electrical power consumption of the transmitter |
4 W |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
0.5 A |
Design of control elements |
p-type |
Scope of delivery
Scope of delivery |
Kit with 2 mounting angles |
Accessory
Recommended safety switchgear |
SRB-E 301 |
Note
Note (General) |
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
Language filter
Datasheet
Mounting and wiring instructions
Operating instructions and Declaration of conformity
BG-test certificate
UL Certificate
Brochure
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
Dimensional drawing basic component
Contact arrangement
Contact arrangement
Schmersal, Inc., 115 E Stevens Ave, Suite 208, Valhalla, NY 10595
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated on: 11/21/2024, 9:59 PM