SRB301SQ 230V

Numéro d'article: 101170100

Téléchargements

TraceParts Données
CADENAS Données CAO
SISTEMA Données
  • 3 safety contacts, STOP 0
  • 1 Signalling output
  • Suitable for the signal processing of outputs with contact sensors

Ordering data

Note (Delivery capacity)

Plus disponible!

Replacement article number

101177166

Product type description

SRB301SQ 230V

Article number (order number)

101170100

EAN (European Article Number)

4250116201501

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

TÜV

cULus

CCC

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Plastique, thermoplastique renforcée de fibres de verre, ventilée

Gross weight

250 g

General data - Features

Electronic Fuse

Oui

Wire breakage detection

Oui

Cross-circuit detection

Oui

Removable Terminals

Oui

Start input

Oui

Feedback circuit

Oui

Automatic reset function

Oui

Reset edge detection

Oui

Earth connection detection

Oui

Integral system diagnostics, status

Oui

Number of auxiliary contacts

1

Number of LEDs

3

Number of normally closed (NC)

2

Number of safety contacts

3

Safety classification

Standards

EN IEC 60947-5-1

EN IEC 61508

Stop-Category

0

Safety classification - Relay outputs

Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

> 99 %

PFH value

2,00 x 10⁻⁸ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Mechanical data

Mechanical lifetime, minimum

10.000.000 Operations

Mounting

Fixation rapide sur rails DIN standards selon DIN EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Allowed type of cable

solid single-wire

flexible

Terminal (mechanical)

1000075113

Mechanical data - Dimensions

Width

22,5 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the installation space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +45 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

10 ... 55 Hz, amplitude 0,35 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

II

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Type of voltage range

AC

Rated operating voltage

48 ... 240 VAC

Rated AC voltage for controls, 50 Hz, minimum

48 VAC

Rated control voltage at AC 50 Hz, maximum

240 VAC

Rated AC voltage for controls, 60 Hz, minimum

48 VAC

Rated control voltage at AC 60 Hz, maximum

240 VAC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

6 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

6 A

Electrical power consumption

2,8 VA

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

à l'état neuf

Drop-out delay in case of emergency, typically

20 ms

Drop-out delay in case of "emergency stop", maximum

25 ms

Pull-in delay at automatic start, maximum, typically

30 ms

Pull-in delay at automatic start, maximum

35 ms

Pull-in delay at RESET, typically

15 ms

Switching frequency, maximum

5 Hz

Material of the contacts, electrical

AgSn0. autonettoyant, à guidage forcé

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

Directive CEM

Status indication

Indicated operating states

Position relais K2

Position relais K1

Other data

Note (applications)

Dispositif de protection

Bouton d'arrêt d'urgence

Interrupteurs de sécurité à commande par câble

Note

Note (General)

Des charges inductives (p.ex. relais externe, etc.) doivent être antiparasitées par un dispositif approprié.

Wiring example

Note (Wiring diagram)

L'exemple de câblage est représenté pour les protecteurs fermés et hors tension.

Partie puissance: une commande à 2 canaux convient pour le renforcement ou la multiplication des contacts par contacteurs ou relais avec contacts à guidage forcé.

La commande détecte les courts-circuits transversaux, les ruptures de câbles et les fuites à la terre dans le circuit de surveillance.

Niveau d'entrée: L'exemple reprend une commande à 2 canaux d'une surveillance de protecteur avec deux interrupteurs de position, dont un avec ouverture forcée, bouton de réarmement externe (R); détection des courts-circuits transversaux et boucle de retour (H2)

Démarrage automatique: Le démarrage automatique s'effectue en connectant la boucle de retour aux bornes S12/X3. Si la boucle de retour n'est pas utilisée, établir un pont.

Filtre de langue

Exemple de câblage (câblage électrique)

Télécharger la dernière version d'Adobe Reader


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

Les données et les valeurs ont été soigneusement vérifiées. Les illustrations peuvent être différentes de l'original. Vous trouverez d'avantage de caractéristiques techniques dans les manuels d’instructions. Sous réserve de modifications techniques et errata.

Généré le: 24/09/2025 01:58