CSS 15-30-2P+D-M-L
CSS 15-30-2P+D-M-L
- Metal enclosure
- Max. 16 sensors can be wired in series.
- Pre-wired cable, 7-pole
- Ø M30
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Ordering data
Product type description |
CSS 15-30-2P+D-M-L |
Article number (order number) |
101209841 |
EAN (European Article Number) |
4030661386805 |
eCl@ss number, version 12.0 |
27-27-46-01 |
eCl@ss number, version 11.0 |
27-27-24-03 |
eCl@ss number, version 9.0 |
27-27-24-03 |
ETIM number, version 7.0 |
EC001829 |
ETIM number, version 6.0 |
EC001829 |
Approvals - Standards
Certificates |
TÜV UKCA |
General data
Standards |
EN IEC 60947-5-3 EN IEC 61508 |
Working principle |
inductivo |
Housing construction form |
Cilindro, rosca |
Installation conditions (mechanical) |
no enrasado |
Sensor topology |
Sensor para conexión en serie |
Housing material |
Latón, niquelado |
Active area |
Plástico |
Reaction time, maximum |
30 ms |
Duration of risk, maximum |
30 ms |
Gross weight |
248 g |
General data - Features
Diagnostic output |
Sí |
Short circuit detection |
Sí |
Cross-circuit detection |
Sí |
Safety functions |
Sí |
Cascadable |
Sí |
Integral system diagnostics, status |
Sí |
Number of LEDs |
1 |
Number of semi-conductor outputs with signaling function |
1 |
Number of fail-safe digital outputs |
2 |
Number of series-wiring of sensors |
16 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
2,50 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data
Actuating panels |
Actuación desde arriba |
Active area |
desde el lado frontal |
Switching distance actuator |
Actuador CST 30-1: 12 mm Actuador CST 30-1: 15 mm Actuador CST 30-1: 19 mm Betätiger CST 34-S-3: 10 mm (gesicherter Schaltabstand EIN Sao) Actuator CST 34-S-3: 12 mm (typical switch distance Sn) Actuator CST 34-S-3: 16 mm (ensured switch distance OFF Sar) |
Mechanical data - Switching distances
Hysteresis (Switching distance), maximum |
2 mm |
Repeat accuracy R |
1 mm |
Mechanical data - Connection technique
Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
Length of cable |
2 m |
Termination |
Cable |
Wire cross-section |
0,25 mm2 |
Wire cross-section |
23 AWG |
Mechanical data - Dimensions
ISO thread of the sensor |
M30 |
Length of sensor |
101 mm |
Ambient conditions
Degree of protection |
IP65 IP67 |
Ambient temperature |
-25 ... +55 °C |
Storage and transport temperature |
-25 ... +85 °C |
Resistance to vibrations |
10…55 Hz, amplitud 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VAC/DC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
No-load supply current I0, typical |
50 mA |
Rated operating voltage |
24 VDC |
Operating current |
1.100 mA |
Required rated short-circuit current |
100 A |
Switching frequency, approx. |
3 Hz |
Utilisation category DC-12 |
24 VDC / 0,05 A |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
0,5 A |
Design of control elements |
tipo p |
Voltage drop Ud, maximum |
0,5 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,5 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,5 A |
Electrical data - Diagnostic outputs
Design of control elements |
Tipo p |
Voltage drop Ud, maximum |
4 V |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,05 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,05 A |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation |
IEC 61000-6-4 |
EMC rating |
IEC 61000-6-2 |
Pin assignment
PIN 1 |
A1 Ue Marrón |
PIN 2 |
X1 entrada de seguridad 1: violeta |
PIN 3 |
A2 GND Azul |
PIN 4 |
Y1 Salida de seguridad 1 Negro |
PIN 5 |
OUT salida de diagnóstico OUT: gris |
PIN 6 |
X2 Entrada de seguridad 2 Blanco |
PIN 7 |
Y2 Salida de seguridad 2 Rojo |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Scope of delivery of mounting material |
2x material de fijación tuercas M30 |
Accessory
Recommendation (actuator) |
CST 34-S-3 CST 30-1 |
Recommended safety switchgear |
PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Note
Note (General) |
Wymagania dotyczące modułu bezpieczeństwa: Moduł bezpieczeństwa musi tolerować czasy wyłączenia w zakresie 250 μs – 1500 μs. |
Filtro de idiomas
Ficha técnica
Manual de instrucciones y declaración de conformidad
Certificado TÜV
Certificado UKCA
SISTEMA-VDMA Biblioteca/Library
Descargar la versión actual de Adobe Reader
Foto de producto (foto individual de catálogo)
Dibujo dimensional Componente básico
Diagrama
Foto de familia (foto grupal)
Curva de características
Declaración de conformidad CE | ![]() |
Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Alemania Internet: www.schmersal.com |
Declaración: | Por el presente documento declaramos que debido a su concepción y tipo de construcción, las piezas relacionadas cumplen con los requisitos de las Directivas Europeas que se indican a continuación. |
Denominación del producto: | CSS 15-30 |
Modelo: | ver código de pedidos |
Descripción de la pieza: | Sensor de seguridad sin contacto |
Directivas aplicables: | Directiva de Máquinas | 2006/42/CE |
Directiva sobre compatibilidad electromagnética CEM | 2014/30/CE | |
Directiva RoHS | 2011/65/CE |
Normas aplicadas: | EN 60947-5-3:2013 EN ISO 14119:2013 EN ISO 13849-1:2015 EN 61508 parte 1-7:2010 |
Entidad designada para la homologación de tipo: | TÜV Rheinland Industrie Service GmbH Am Grauen Stein, 51105 Köln Certif. núm.: 0035 |
Certificación de homologación de tipo CE: | 01/205/5874.00/21 |
Responsable de la recopilación de la documentación técnica: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
Lugar y fecha de emisión: | Wuppertal, 29 de noviembre de 2021 |
![]() |
Firma legal Philip Schmersal Director General |
UK Declaration of Conformity | ![]() |
Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
Name of the component: | CSS 15-30 |
Type: | See ordering code |
Description of the component: | Non-contact safety sensor |
Relevant legislation: | Supply of Machinery (Safety) Regulations | 2008 |
Electromagnetic Compatibility Regulations | 2016 | |
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
Designated standards: | EN 60947-5-3:2013 EN ISO 14119:2013 EN ISO 13849-1:2015 EN 61508 parts 1-7:2010 |
Approved body for Type Examination: | TÜV Rheinland UK Ltd. 1011 Stratford Road Solihull, B90 4BN ID: 2571 |
Type examination certificate: | 01/205U/5874.00/23 |
UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
Place and date of issue: | Wuppertal, February 6, 2023 |
![]() |
Authorised signature Philip Schmersal Managing Director |
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Los datos e información anteriores se han verificado cuidadosamente. Las imágenes pueden diferir del original. Se pueden encontrar más datos técnicos en los manuales de instrucciones. Sujeto a cambios técnicos y errores.
Generado a 9/4/2025 16:39