schmersal_s_icon.png

MS-AZM 200ST-T-1P2PW-2568

项目编号: 103004836

下载

追踪备件 CAD数据
计划 数据
CADENAS CAD数据
Product type description:

AZM 200(1)(2)-T-(3)(4)


(1)
withoutGuard locking monitored >
BActuator monitored

(2)
SKScrew connection
CCCage clamp
ST1Connector M23 x 1, (8+1 pole)
ST2Connector M12 x 1, 8 pole

(3)
1P2P1 serial diagnostic output and 2 p-type safety outputs
1P2PWsame as 1P2P, combined diagnostic signal: guard system closed and interlock locked
SD2Pserial diagnostic output and 2 p-type safety outputs

(4)
withoutPower to unlock
APower to lock
并非所有根据本订单代码可能的组件变体都可用和/或在技术上可行。
  • Guard locking monitored
  • Connector M23 12-pole,
  • Idle assignable pushbutton and LED
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Max. length of the sensor chain 200 m
  • Self-monitoring series-wiring
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
  • Manual release

Ordering data

Note (Delivery capacity)

不支持!

Product type description

MS-AZM 200ST-T-1P2PW-2568

Article number (order number)

103004836

EAN (European Article Number)

4030661433455

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

General data

Standards

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 61508

Coding

通用编码

Coding level according to EN ISO 14119

Working principle

感应

Housing material

玻璃纤维,加强型热塑塑料

Reaction time, maximum

60 ms

Duration of risk, maximum

120 ms

Gross weight

610 g

General data - Features

Power to unlock

Solenoid interlock monitored

Manual release

Short circuit detection

Cross-circuit detection

Series-wiring

Idle assignable pushbutton

Freely assignable LED

Safety functions

Integral system diagnostics, status

Number of safety contacts

2

Safety classification

Vorschriften

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Mission time

20 Year(s)

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

4.00 x 10⁻⁹ /h

PFD value

1.00 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety classification - Guard locking function

Performance Level, up to

d

Category

2

PFH value

2.50 x 10⁻⁹ /h

PFD value

2.20 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Holding force FZh in accordance with EN ISO 14119

2,000 N

Note (clamping force FZh)

1,000 N 当使用↲AZ/ AZ/AZM201-B30操动件,用于室内.

Holding force Fmax, maximum

2,600 N

Note (clamping force Fmax)

1,300 N 当使用↲AZ/ AZ/AZM201-B30操动件,用于室内.

Latching force

30 N

Actuating speed, maximum

0.2 m/s

Tightening torque of the fastening screws for the housing cover, minimum

0.7 Nm

Tightening torque of the fastening screws for the housing cover, maximum

1 Nm

Note

Torx T10

Mechanical data - Connection technique

Termination

连接器M23,12芯

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

40 mm

Height of sensor

220 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature

-25 ... +50 °C

Storage and transport temperature

-25 ... +85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

无冷凝

Resistance to vibrations

10 ... 55 Hz,振幅 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 %

No-load supply current I0, typical

600 mA

Rated operating voltage

24 VDC

Operating current

1,200 mA

Time to readiness, maximum

4,000 ms

Switching frequency, approx.

1 Hz

Electrical fuse rating, maximum

4 A

Electrical data - Magnet control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Magnet switch-on time

100 %

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24 V

5 mA

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Voltage drop Ud, maximum

4 V

Leakage current Ir, maximum

0.5 mA

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Electrical data - Diagnostic outputs

Operating current

50 mA

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Status indication

Note (LED switching conditions display)

工作状态:LED绿色

错误 / 功能故障:LED红色

供电电压 UB:LED 绿色

Pin assignment

PIN 1

A1 电源电压 UB

PIN 2

X1 安全输入 1

PIN 3

A2 GND

PIN 4

Y1 安全输出 1

PIN 5

OUT 监控输出

PIN 6

X2 安全输入 2

PIN 7

Y2 安全输出 2

PIN 8

IN 线圈控制

PIN 9

白色LED

PIN 10

按钮

PIN 11

按钮

PIN 12

未使用

Scope of delivery

Scope of delivery

操动件#必须单独订购.

AZM200用的三角钥匙

Accessory

Recommendation (actuator)

AZ/AZM 200-B1

Note

Note (General)

只要操动件保持插入在电磁安全锁中,已解锁的防护门会重新锁定。在这种情况下,安全输出将重新启用,因此不能打开安全防护装置。

语言条件

下载最新版本的Adobe Reader

103025499 AZM201Z-ST-T-1P2PW-2965-1
  • Thermoplastic enclosure
  • Max. length of the sensor chain 200 m
  • Self-monitoring series-wiring
  • Coding in accordance to ISO 14119 by using RFID-Technology
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Suitable for hinged and sliding guards
  • Intelligent diagnosis
  • Manual release
  • Protection class IP66, IP67
  • High holding force 2000
  • symmetrical construction form, assembly on 40mm profiles
  • OSSD safety outputs
  • Emergency exit / Emergency release suitable for retrofitting


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

所涉及的详细信息和数据已经过仔细检查。 图像可能与原始图像有所不同。 您可在说明书中进一步获得技术数据。 可能会有技术修改和错误。

生成日期 2025/4/26 下午9:58