  • 2 safety contacts, STOP 0
  • 6 Signalling outputs
  • Multi-evaluation of up to 6 safety guards
  • Suitable for the signal processing of outputs with contact sensors

Ordering data

Note (Delivery capacity)

Niet meer verkrijgbaar!

Replacement article number

101177163

Product type description

SRB206SQ-230V

Article number (order number)

101174016

EAN (European Article Number)

4250116201891

eCl@ss number, version 12.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 9.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

cULus

General data

Standards

EN IEC 62061

EN ISO 13849-1

EN IEC 60947-5-1

EN IEC 60947-5-3

EN IEC 60947-5-5

EN IEC 61508

EN IEC 60204-1

EN IEC 60947-1

Climatic stress

EN 60068-2-78

Housing material

Kunststof, glasvezelversterkte thermoplast, geventileerd

Gross weight

400 g

General data - Features

Electronic Fuse

Ja

Wire breakage detection

Ja

Cross-circuit detection

Ja

Removable Terminals

Ja

Start input

Ja

Feedback circuit

Ja

Automatic reset function

Ja

Reset edge detection

Ja

Earth connection detection

Ja

Integral system diagnostics, status

Ja

Number of auxiliary contacts

6

Number of LEDs

4

Number of normally closed (NC)

12

Number of safety contacts

2

Number of signalling outputs

6

Safety classification

Vorschriften

EN IEC 60947-5-1

EN IEC 61508

Stop-Category

0

Safety classification - Relay outputs

Performance Level, stop 0, up to

d

Category, Stop 0

3

Diagnostic Coverage (DC) Level, Stop 0

> 60 %

PFH value, Stop 0

2,00 x 10⁻⁷ /h

Safety Integrity Level (SIL), Stop 0, suitable for applications in

2

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Mechanical data

Mechanical life, minimum

10.000.000 Operations

Mounting

Snelbevestiging voor DIN-rail volgens DIN EN 60715

Mechanical data - Connection technique

Terminal designations

IEC/EN 60947-1

Termination

stijf of flexibel

Schraubanschluss M20 x 1.5

Cable section, minimum

0,25 mm²

Cable section, maximum

2,5 mm²

Tightening torque of Clips

0,6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature

-25 ... +45 °C

Storage and transport temperature

-40 ... +85 °C

Resistance to vibrations

10...55 Hz, Amplitude 0,35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage Uimp

4 kV

Overvoltage category

III

Degree of pollution

2

Electrical data

Frequency range

50 Hz

60 Hz

Type of voltage range

AC

Rated operating voltage

48 ... 240 VAC

Operating current

275 mA

Rated AC voltage for controls, 50 Hz, minimum

48 VAC

Rated control voltage at AC 50 Hz, maximum

240 VAC

Rated AC voltage for controls, 60 Hz, minimum

48 VAC

Rated control voltage at AC 60 Hz, maximum

240 VAC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

6 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

6 A

Electrical power consumption

6,8 W

Contact resistance, maximum

0,1 Ω

Note (Contact resistance)

In nieuwe toestand

Drop-out delay in case of "emergency stop", maximum

30 ms

Pull-in delay at RESET, typically

50 ms

Material of the contacts, electrical

AgCdO, zelfreinigend, gedwongen uitgevoerd

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Richtlijn

Status indication

Indicated operating states

Positie relais K2

Positie relais K1

Interne bedrijfsspanning Ui

Other data

Note (applications)

Beschermvoorziening

Noodstopknop

Noodstop-trekkoordschakelaars

Note

Note (General)

Inductieve verbruikers (externe relais, enz.) zijn via een aangepaste bedrading te ontstoren.

Wiring example

Note (Wiring diagram)

Het schakelvoorbeeld is afgebeeld bij gesloten beschermvoorzieningen en in spanningsloze toestand.

Automatische start: De automatische start wordt geprogrammeerd door het aansluiten van de terugkoppeling op de klemmen X1/X3. Als de terugkoppeling niet nodig is, moet hier een overbrugging gemaakt worden.

Vermogensvlak: voldoet voor 2-kanalige aansturing,als contactversterking en/of contactvermenigvuldiging via externe relais met gedwongen uitgevoerde contacten.

De sturing herkent dwarssluitingen, kabelbreuken en aardlekken in het bewakingscircuit.

Ingangsniveau: Het voorbeeld toont een 2-kanalige aansturing van een veiligheidsdeurbewaking met twee positieschakelaars, waarvan een met gedwongen verbreking, externe resetknop (R<); dwarssluitbewaking en terugkoppeling (H2)

Als meer veiligheidsdeuren bewaakt worden, moeten deze volgens de aansluittabel aangesloten worden

Een eenvoudige storing van de sensoren leidt niet tot het verlies van veiligheid

Als de afzonderlijke fout zich voordoet, blijft de veiligheidsfunctie altijd behouden. Sommige fouten, niet alle, worden herkend. Een opeenstapeling van niet-herkende fouten kan tot het verlies van de veiligheidsfunctie leiden.

Taalfilter

Schakelvoorbeeld (elektrische kabels)

Download de nieuwste versie van Adobe Reader

103008070 SRB-E-204PE
  • Plug-in screw terminals with coding
  • Input expander module
  • 1 oder 2-channel control
  • Monitoring of 4 sensors
  • 2 Safety outputs
  • 4 Signalling outputs

103009973 SRB-E-204ST
  • Plug-in screw terminals with coding
  • STOP 0 Function
  • Monitoring of 4 sensors
  • Start button / Auto-start
  • 2 Safety outputs
  • 4 Signalling outputs


Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220

De genoemde gegevens en informatie zijn zorgvuldig gecontroleerd. Afbeeldingen kunnen afwijken van het origineel. Verdere technische gegevens zijn te vinden in de handleiding. Technische wijzigingen en fouten voorbehouden.

Gegenereerd op 24-03-2025 12:14