SRB206SQ 24V AC/DC
SRB206SQ 24V AC/DC
Downloads
- 2 safety contacts, STOP 0
- 6 Signalling outputs
- Multi-evaluation of up to 6 safety guards
- Suitable for the signal processing of outputs with contact sensors
Ordering data
Note (Delivery capacity) |
Nicht mehr lieferbar! |
Product type description |
SRB206SQ 24V AC/DC |
Article number (order number) |
101173934 |
EAN (European Article Number) |
4250116201877 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Kunststoff, glasfaserverstärkter Thermoplast, belüftet |
Gross weight |
400 g |
General data - Features
Electronic Fuse |
Ja |
Wire breakage detection |
Ja |
Cross-circuit detection |
Ja |
Removable Terminals |
Ja |
Start input |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Reset edge detection |
Ja |
Reset after disconnection of supply voltage |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of auxiliary contacts |
6 |
Number of LEDs |
4 |
Number of normally closed (NC) |
12 |
Number of safety contacts |
2 |
Number of signalling outputs |
6 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
d |
Category, Stop 0 |
3 |
Diagnostic Coverage (DC) Level, Stop 0 |
> 60 % |
PFH value, Stop 0 |
2,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
2 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanical data
Mechanical life, minimum |
10.000.000 Operations |
Mounting |
Schnellbefestigung für Normschiene nach DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
starr oder flexibel Schraubanschluss M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, Amplitude 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Operating current |
275 mA |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
6 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
6 A |
Electrical power consumption |
3,6 W |
Electrical power consumption |
6,6 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
in Neuzustand |
Drop-out delay in case of "emergency stop", maximum |
30 ms |
Pull-in delay at RESET, typically |
50 ms |
Material of the contacts, electrical |
AgCdO, selbstreinigend, zwangsgeführt |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMV-Richtlinie |
Status indication
Indicated operating states |
Stellung der Relais K2 Stellung der Relais K1 Interne Betriebsspannung Ui |
Other data
Note (applications) |
Schutzeinrichtung NOT-HALT-Taster Seilzug-Notschalter |
Note
Note (General) |
Induktive Verbraucher (Schütze, Relais etc.) sind durch eine geeignete Beschaltung zu entstören. |
Wiring example
Note (Wiring diagram) |
Das Schaltungsbeispiel ist bei geschlossenen Schutzeinrichtungen und im spannungslosen Zustand dargestellt. Automatischer Start: Die Programmierung auf automatischen Start erfolgt durch die Einbindung des Rückführkreises an die Klemmen X1/X3. Bei nicht benötigtem Rückführkreis ist dieser durch eine Brücke zu ersetzen. Leistungsebene: 2-kanalige Ansteuerung geeignet zur Kontaktverstärkung bzw. Kontaktvervielfältigung durch Schütze oder Relais mit zwangsgeführten Kontakten. Die Ansteuerung erkennt Querschlüsse, Drahtbrüche und Erdschlüsse im Überwachungskreis. Eingangsebene: 2-kanalige Ansteuerung, dargestellt am Beispiel einer Schutztürüberwachung mit zwei Positionsschaltern, davon einer zwangsöffnend, externem Reset-Taster (R); Querschlusserkennung und Rückführkreis (H2) Werden mehr Schutztüren überwacht, sind diese gemäß der Anschlusstabelle anzuschließen. Ein einzelner Fehler bei den Sensoren führt nicht zum Verlust der Sicherheit. Wenn der einzelne Fehler auftritt, bleibt die Sicherheitsfunktion immer erhalten. Einige, aber nicht alle Fehler werden erkannt. Eine Anhäufung unerkannter Fehler kann zum Verlust der Sicherheitsfunktion führen. |
Sprachfilter
Datenblatt
Montage- und Anschlussanleitung
Betriebsanleitung und Konformitätserklärung
UL-Zertifikat
Schaltungsbeispiel (elektr. Verdrahtung)
Kraftwegdiagramm
Download der aktuellen Version von Adobe Reader
Produktbild (Katalogeinzelphoto )
Schaltungsbeispiel
Schaltungsbeispiel
Symbol (technischer Standard)
103008070 SRB-E-204PE
- Plug-in screw terminals with coding
- Input expander module
- 1 oder 2-channel control
- Monitoring of 4 sensors
- 2 Safety outputs
- 4 Signalling outputs
103009973 SRB-E-204ST
- Plug-in screw terminals with coding
- STOP 0 Function
- Monitoring of 4 sensors
- Start button / Auto-start
- 2 Safety outputs
- 4 Signalling outputs
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Die genannten Daten und Angaben wurden sorgfältig geprüft. Abbildungen können vom Original abweichen. Weitere technische Daten finden Sie in der Betriebsanleitung. Technische Änderungen und Irrtümer vorbehalten.
Generiert am: 24.03.2025, 10:15