SRB206ST 24V AC/DC
SRB206ST 24V AC/DC
Downloads
- 2 safety contacts, STOP 0
- 6 Signalling outputs
- Multi-evaluation of up to 6 safety guards
- Suitable for the signal processing of outputs with contact sensors
Ordering data
Note (Delivery capacity) |
Ikke tilgjengelig! |
Replacement article number |
101177165 |
Product type description |
SRB206ST 24V AC/DC |
Article number (order number) |
101173536 |
EAN (European Article Number) |
4250116201853 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Plast, glassfiber forsterket termoplast, ventilert |
Gross weight |
250 g |
General data - Features
Electronic Fuse |
Ja |
Wire breakage detection |
Ja |
Removable Terminals |
Ja |
Start input |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Reset edge detection |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of auxiliary contacts |
6 |
Number of LEDs |
4 |
Number of normally closed (NC) |
12 |
Number of safety contacts |
2 |
Number of signalling outputs |
6 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
d |
Category, Stop 0 |
3 |
Diagnostic Coverage (DC) Level, Stop 0 |
> 60 % |
PFH value, Stop 0 |
2,00 x 10⁻⁷ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanical data
Mechanical life, minimum |
10 000 000 Operations |
Mounting |
kneppes inn på standard DIN-skinne iht. EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
Stiv eller fleksibel Skrueforbindelse M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10...55 Hz, Amplitude 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Operating current |
275 mA |
Rated AC voltage for controls, 50 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20,4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26,4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
6 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
6 A |
Electrical power consumption |
3,6 W |
Electrical power consumption |
6,6 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
I ny tilstand |
Drop-out delay in case of "emergency stop", maximum |
30 ms |
Pull-in delay at RESET, typically |
50 ms |
Material of the contacts, electrical |
AgCdO, selvrensende, positiv handling |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Directive |
Status indication
Indicated operating states |
Posisjon relé K2 Posisjon relé K1 Intern driftsspenning Ui |
Other data
Note (applications) |
sikkerhetsinnretning Nødstoppknapp Trekkwire-nødstoppbrytere |
Note
Note (General) |
Induktive belastninger (f.eks. kontaktorer, reléer, etc.) må undertrykkes ved hjelp av en egnet krets. |
Wiring example
Note (Wiring diagram) |
Kablingsskjemaet vises med vernedørene lukket og i de-energisert tilstand. Automatisk start: Automatisk start programmeres ved å koble tilbakemeldingskretsen til terminalene X1/X3 Dersom tilbakemeldingskrets ikke er nødvendig, etabler en bro Inngangsnivå: Eksemplet viser en 2-kanalskontroll av en vernedørovervåking med to posisjonsbrytere, derav én med tvangsbrytende, ekstern tilbakestillingsknapp (R) og tilbakemeldingskrets (H2). Kontrollsystemet gjenkjenner ledningsbrudd og jordingsfeil i overvåkingskretsen. Reléutganger: Egnet for 2-kanalkontroll, for økt kapasitet eller flere kontakter med hjelp av kontaktorer eller releer med positivt styrte kontakter. Dersom flere vernedører er overvåket, må de tilkobles i henhold til kablingsskjemaet En enkelt feil i sensorene fører ikke til at sikkerheten går tapt Dersom en enkelt svikt forekommer, vil sikkerhetsfunksjonen bli opprettholdt. Noen feil vil bli registrert, men ikke alle. En akkumulering av uregistrerte feil kan føre til at sikkerhetsfunksjonen går tapt. |
Språk filter
Datablad
Bruksanvisning og konformitetserklæring
UL sertifikat
kablingseksempel (elektr. kabling)
Kraft - vei diagram
Last ned den nyeste versjonen av Adobe Reader
Produktbilde (enkelt katalogbilde)
kablingseksempel
Symbol (teknisk standard)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
Data og verdier er kontrollert omhyggelig. Bilder kan avvike fra originalen. Ytterligere tekniske data finner du i manualen. Tekniske modifiseringer og feil kan forkomme.
Generert til 22.03.2025, 08:59