SSW301HV-230V
SSW301HV-230V
Downloads
- Fail-safe standstill monitors
- This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning.
- 3 safety contacts, STOP 0
- Control category 4 to ISO 13849-1
Ordering data
Note (Delivery capacity) |
Non più disponibile! |
Product type description |
SSW301HV-230V |
Article number (order number) |
101182218 |
EAN (European Article Number) |
4250116202591 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus CCC |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
materiale sintetico, termoplastica rinforzata con fibra di vetro |
Gross weight |
500 g |
General data - Features
Wire breakage detection |
Sì |
Cross-circuit detection |
Sì |
Feedback circuit |
Sì |
Automatic reset function |
Sì |
Earth connection detection |
Sì |
Integral system diagnostics, status |
Sì |
Number of auxiliary contacts |
1 |
Number of LEDs |
5 |
Number of safety contacts |
3 |
Safety classification |
Vorschriften |
EN ISO 13849-1 EN IEC 61508 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mechanical data
Mechanical life, minimum |
10.000.000 Operations |
Mounting |
fissaggio rapido per guide DIN secondo DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
rigido o flessibile Collegamento a vite M20 x 1.5 |
Cable section, minimum |
0,5 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
90 mm |
Height |
83 mm |
Depth |
127 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the mounting space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, ampiezza 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Degree of pollution |
2 |
Electrical data
Operating voltage |
230 VAC -15 % / +10 % |
Rated operating voltage |
230 VAC |
Rated AC voltage for controls, 50 Hz, minimum |
195,5 VAC |
Rated control voltage at AC 50 Hz, maximum |
253 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
195,5 VAC |
Rated control voltage at AC 60 Hz, maximum |
253 VAC |
Electrical power consumption, maximum |
4 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
in perfette condizioni |
Drop-out delay in case of "emergency stop", maximum |
15 ms |
Pull-in delay at automatic start (after detecting standstill), approx. |
7.000 ms |
Material of the contacts, electrical |
AgSn0 + Au, autopulente, azione obbligata |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 |
230 VAC |
Current, Utilisation category AC-15 |
6 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
6 A |
Switching capacity, minimum |
10 VDC |
Switching capacity, minimum |
10 mA |
Switching capacity, maximum |
250 VAC |
Switching capacity, maximum |
8 A |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum |
24 VDC |
Switching capacity, maximum |
2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
Direttiva EMC |
Status indication
Indicated operating states |
OUT, verde: abilitazione stato di commutazione UB: tensione di alimentazione presente ERR: Errore distrubo della funzione |
Other data
Note (applications) |
safe controllo di arresto |
Note
Note (General) |
Soppresori induttivi (contattore, relè ecc.) vanno ripristinati con una commutazione idonea. |
Wiring example
Note (Wiring diagram) |
OUT: Rilascio contatti di sicurezza 13-14, 23-24 chiusi |
Filtro lingua
Scheda Tecnica
Manuale d'istruzioni e dichiarazione UE di conformità
Certificazione UL
Cetificato CCC
Esempio di collegamento (cablaggio elettrico)
Download dell'ultima versione di Adobe Reader
Immagine del prodotto (foto singola per catalogo)
Esempio di azionamento
Simbolo (standard tecnico)
103034847 SSW303HV
- Standstill detection time 7s
- Fail-safe standstill monitors
- 3 safety contacts
- 3 Signalling contacts
- Sensor-free detection of standstill by monitoring e.m.f.
- Direct connection to three-phase motors
- Motor voltage range 0 ... 690 V
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
I dettagli e i dati qui riportati sono stati attentamente verificati. Le immagini possono differire dagli originali. Altri dati tecnici possono essere trovati nei manuali. Salvo modifiche tecniche o errori.
Generato il 25/03/2025, 12:46