SRB308IT-24VAC/DC
SRB308IT-24VAC/DC
Downloads
- Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit recognition, Level 2: / Opener (NC) Normally open contact (NO)
- Multifunctional safety relay module for superior diagnostics and visualisation
- Suitable for the signal processing of outputs with contact sensors
- Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
- Suitable for the signal processing of outputs with contact sensors
- 3 safety contacts, STOP 0
- 2 + 6 Signalling outputs
Ordering data
Note (Delivery capacity) |
Non più disponibile! |
Replacement article number |
101159511 |
Product type description |
SRB308IT-24VAC/DC |
Article number (order number) |
101158200 |
EAN (European Article Number) |
4250116201556 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
materiale sintetico, termoplastica rinforzata con fibra di vetro, ventilata |
Gross weight |
480 g |
General data - Features
Electronic Fuse |
Sì |
Wire breakage detection |
Sì |
Cross-circuit detection |
Sì |
Removable Terminals |
Sì |
Start input |
Sì |
Feedback circuit |
Sì |
Automatic reset function |
Sì |
Reset edge detection |
Sì |
Earth connection detection |
Sì |
Integral system diagnostics, status |
Sì |
Number of auxiliary contacts |
2 |
Number of LEDs |
5 |
Number of normally closed (NC) |
2 |
Number of undelayed semi-conductor outputs with signaling function |
6 |
Number of safety contacts |
3 |
Number of signalling outputs |
6 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mechanical data
Mechanical lifetime, minimum |
10.000.000 Operations |
Mounting |
fissaggio rapido per guide DIN secondo DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Termination |
rigido o flessibile Collegamento a vite M20 x 1.5 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the installation space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10 ... 55 Hz, ampiezza 0,35 mm |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VAC -15 % / +10 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VAC |
Rated operating voltage |
24 VDC |
Operating current |
125 mA |
Rated AC voltage for controls, 50 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 50 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum |
20.4 VAC |
Rated control voltage at AC 60 Hz, maximum |
26.4 VAC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Utilisation category AC-15 |
230 VAC |
Utilisation category AC-15 |
1,5 A |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
1,2 A |
Electrical power consumption |
3 W |
Electrical power consumption |
3 VA |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
in perfette condizioni |
Drop-out delay in case of "emergency stop", maximum |
15 ms |
Pull-in delay at automatic start, maximum, typically |
60 ms |
Pull-in delay at RESET, typically |
200 ms |
Material of the contacts, electrical |
AgSn0, Ag-Ni, autopulente, azione obbligata |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
Direttiva EMC |
Status indication
Indicated operating states |
posizione dei relè K2 posizione dei relè K1 tensione d'esercizio interna Ui posizione dei relè K3 |
Other data
Note (applications) |
Dispositivo di protezione Pulsante di arresto d'emergenza Interruttori a fune d'emergenza Cortine ottiche di sicurezza |
Note
Note (General) |
Soppresori induttivi (contattore, relè ecc.) vanno ripristinati con una commutazione idonea. |
Wiring example
Note (Wiring diagram) |
L'esempio di commutazione è rappresentato con dispositivi di sicurezza chiusi e in condizione senza tensione. Le tabelle ISD (diagnosi integrata nel sistema) per l'analisi delle segnalazioni di errore e le loro cause, sono riportate nell'appendice. Livello di performance: azionamento 2 canale, adatto per il rafforzamento, quindi la duplicazione, dei contatti mediante contattori, oppure relè con contatti ad azione obbligata. Il controllo riconosce cortocircuiti trasversali, rotture di cavo e dispersioni verso terra nel circuito sorvegliato. Collegare le uscite con potenziale di griglie e cortine ottiche (commutazione p) con S12/S22. I dispositivi devono trovarsi sullo stesso potenziale di riferimento. Azionamento a 2 canali rappresentato con l'esempio di un controllo di porte di sicurezza con due contatti, di cui almeno un contatto ad apertura obbligata; con tasto reset estremo (R) e circuito di ritorno (H2). (esempio senza controllo di contatto trasversale) In caso di controllo bicanale con controllo di cortocircuito trasversale collegare i contatti NC S11/S12 e S31/S32 e ponticellare S21/S22 Con controllo monocanale collegare il contatto NC S11/S12 e ponticellare S21/S22 e S31/S32 Funzione di avvio / Pulsante reset: la programmazione della funzione "Fronte di discesa" avviene mediante lo switch AF sotto il coperchio della custodia (impostazione switch = 1). La programmazione dell'avvio automatico avviene ponticellando i morsetti X3/X5 e impostando lo switch "AF" su 0. Lo scostamento temporale tra i canali è di ca. 100 ms. Per programmare uno scostamento temporale infinito tra i canali 1 e 2 ponticellare i morsetti X3/X6. F1 = fusibile ibrido F2 = protezione segnalazione di uscite |
Filtro lingua
Scheda Tecnica
Manuale d'istruzioni e dichiarazione UE di conformità
Certificazione UL
Esempio di collegamento (cablaggio elettrico)
Diagramma della corsa di forza
Download dell'ultima versione di Adobe Reader
Immagine del prodotto (foto singola per catalogo)
Esempio di azionamento
Esempio di azionamento
Esempio di azionamento
Simbolo (standard tecnico)
103007672 SRB-E-301ST
- Plug-in screw terminals with coding
- STOP 0 Function
- 1 oder 2-channel control
- Start button / Auto-start
- 1 Auxiliary contact
- 3 safety contacts
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220