AZ 3350-12ZUEK-U270
| 製品タイプの説明: AZ 3350-(1)-(2)-(3) |
| (1) | |
| 03ZK | 3 NC接点 |
| 12ZUEK | 1 NO 接点/2 NC 接点 |
| (2) | |
| 1637 | 金メッキ接点 |
| (3) | |
| U90 | アクチュエーターヘッドは、左ヒンジドア用に90°回す事が出来ます。 |
| U270 | アクチュエーターヘッドは、右ヒンジドア用に 270°回す事が出来ます。 |
- Metal enclosure
- Latching handle
- Long life
- 40,5 mm x 114 mm x 38 mm
- High level of contact reliability with low voltages and currents
Ordering data
| Product type description |
AZ 3350-12ZUEK-U270 |
| Article number (order number) |
151174720 |
| EAN (European Article Number) |
4030661304137 |
| eCl@ss number, version 12.0 |
27-27-26-02 |
| eCl@ss number, version 11.0 |
27-27-26-02 |
| eCl@ss number, version 9.0 |
27-27-26-02 |
| ETIM number, version 7.0 |
EC002592 |
| ETIM number, version 6.0 |
EC002592 |
| Note (Ordering data) |
To order, first choose the desired safety switch and then the door handle system |
Approvals - Standards
| Certificates |
cULus CCC |
General data
| Standards |
BG-GS-ET-15 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
| Coding level according to EN ISO 14119 |
Low |
| Working principle |
電気機械式 |
| Housing material |
アルミニウム |
| Housing coating material |
塗装 |
| Gross weight |
230 g |
General data - Features
| Number of actuating directions |
1 |
| Number of auxiliary contacts |
1 |
| Number of safety contacts |
2 |
| Number of cable glands |
1 |
| Safety classification |
| Standards |
EN ISO 13849-1 |
| Mission time |
20 Year(s) |
Safety classification - Safety outputs
| B10D Normally-closed contact (NC) |
2,000,000 Operations |
| B10D Normally open contact (NO) |
1,000,000 Operations |
| Note (B10D Normally open contact (NO)) |
at 10% Ie and ohmic load |
Mechanical data
| Mechanical lifetime, minimum |
1,000,000 Operations |
| Door hinge |
Right |
| Shearing force |
15,000 N |
| Positive break travel |
10.7 mm |
| Positive break force per NC contact, minimum |
5 N |
| Actuating speed, maximum |
0.2 m/s |
| Mounting |
ネジ |
Mechanical data - Connection technique
| Cable entry |
1 x M20 |
| Termination |
ネジ端子 ネジ端子 M20 x 1.5 |
| Cable section, minimum |
0.75 mm² |
| Cable section, maximum |
2.5 mm² |
| Note |
All indications including the conductor ferrules. |
| Allowed type of cable |
ソリッド単線 ソリッド・マルチワイヤー 柔軟な |
Mechanical data - Dimensions
| Length of sensor |
38 mm |
| Width of sensor |
40.5 mm |
| Height of sensor |
114 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-30 ... +90 °C |
| Storage and transport temperature |
-40 ... +90 °C |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
250 VAC |
| Rated impulse withstand voltage Uimp |
4 kV |
Electrical data
| Thermal test current |
10 A |
| Required rated short-circuit current |
1,000 A |
| Switching element |
NO 接点、NC 接点 |
| Switching principle |
スローアクションのオーバーラップ接点 |
| Maximale Schalthäufigkeit |
1,200 /h |
| Material of the contacts, electrical |
銀 |
Electrical data - Safety contacts
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
4 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
4 A |
Electrical data - Auxiliary contacts
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
4 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
4 A |
Scope of delivery
| Scope of delivery |
Actuator must be ordered separately. |
Accessory
| Recommendation (actuator) |
AZ 3350-B1 AZ 3350-B5 AZ 3350-B1R AZ 3350-B5R AZ 3350-B6 AZ 3350-B6H |
| Recommendation (product combination) |
AZ 3350-STS30-01 AZ 3350-STS30-03 AZ 3350-STS30-06 AZ 3350-STS30-08 |
言語フィルター
データシート
Operating instructions and Declaration of conformity
CCC certification
UL Certificate
SISTEMA-VDMA library
Adobe Readerの最新版をダウンロードしてください
Product picture (catalogue individual photo)
Dimensional drawing basic component
Dimensional drawing miscellaneous
Dimensional drawing miscellaneous
Diagram
Operating principle
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
データと詳細は完全にチェックされました。画像は元の画像と異なる場合があります。技術的なデータはマニュアルで見られます。技術的に変更されたり、エラーの可能性があります。
Generated on 2025/10/24 8:07