CSS 8-16-2P-E-LST
CSS 8-16-2P-E-LST
- Connector M12, 4-pole
- NOTICE: Not available! (Replacement: RSS16)
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Misaligned actuation possible
- 55 mm x 93 mm x 39.5 mm
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- Early warning when operating near the limit of the sensor's hysteris range
- Self-monitoring series-wiring of 16 sensors
- 2 short-circuit proof PNP safety outputs
Ordering data
Note (Delivery capacity) |
Niet meer verkrijgbaar! |
Product type description |
CSS 8-16-2P-E-LST |
Article number (order number) |
101210575 |
EAN (European Article Number) |
4030661388915 |
eCl@ss number, version 12.0 |
27-27-46-01 |
eCl@ss number, version 11.0 |
27-27-24-03 |
eCl@ss number, version 9.0 |
27-27-24-03 |
ETIM number, version 7.0 |
EC001829 |
ETIM number, version 6.0 |
EC001829 |
Approvals - Standards
Certificates |
cULus |
General data
Standards |
EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Coding level according to EN ISO 14119 |
gering |
Working principle |
inductief |
Housing construction form |
Blok |
Installation conditions (mechanical) |
niet vlak |
Sensor topology |
Eind- of individuele component |
Housing material |
Kunststof, glasvezelversterkte thermoplast, zelfdovend |
Active area |
Kunststof, glasvezelversterkte thermoplast |
Reaction time, maximum |
30 ms |
Duration of risk, maximum |
30 ms |
Gross weight |
285 g |
General data - Features
Short circuit detection |
Ja |
Cross-circuit detection |
Ja |
Safety functions |
Ja |
Integral system diagnostics, status |
Ja |
Number of fail-safe digital outputs |
2 |
Number of series-wiring of sensors |
16 |
Safety classification |
Vorschriften |
EN IEC 60947-5-3 EN IEC 61508 |
Performance Level, up to |
e |
Category |
4 |
PFH value |
2,50 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in |
3 |
Mission time |
20 Year(s) |
Mechanical data - Switching distances
Switch distance, typical |
8 mm |
Assured switching distance "ON" Sao |
6 mm |
Assured switching distance "OFF" Sar |
11 mm |
Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
Hysteresis (Switching distance), maximum |
1 mm |
Repeat accuracy R |
0,5 mm |
Mechanical data - Connection technique
Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
Length of cable |
2 m |
Termination |
Kabel met stekker |
Terminal connector, Output |
Stekker M12, 4-polig |
Mechanical data - Dimensions
Length of sensor |
39,5 mm |
Width of sensor |
55 mm |
Height of sensor |
93 mm |
Ambient conditions
Degree of protection |
IP65 IP67 |
Ambient temperature |
-25 ... +55 °C |
Storage and transport temperature |
-25 ... +85 °C |
Resistance to vibrations |
10…55 Hz, amplitude 1 mm |
Restistance to shock |
30 g / 11 ms |
Protection class |
II |
Ambient conditions - Insulation values
Rated insulation voltage Ui |
32 VDC |
Rated impulse withstand voltage Uimp |
0,8 kV |
Overvoltage category |
III |
Degree of pollution |
3 |
Electrical data
Operating voltage |
24 VDC -15 % / +10 % |
No-load supply current I0, typical |
50 mA |
Rated operating voltage |
24 VDC |
Operating current |
1.100 mA |
Switching frequency, approx. |
3 Hz |
Electrical data - Safety digital outputs
Output current, (fail-safe output), maximum |
0,5 A |
Design of control elements |
p-schakelend |
Voltage drop Ud, maximum |
0,5 V |
Leakage current Ir, maximum |
0,5 mA |
Voltage, Utilisation category DC-12 |
24 VDC |
Current, Utilisation category DC-12 |
0,5 A |
Voltage, Utilisation category DC-13 |
24 VDC |
Current, Utilisation category DC-13 |
0,5 A |
Electrical data - Diagnostic outputs
Design of control elements |
p-schakeling |
Voltage drop Ud, maximum |
4 V |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation |
IEC 61000-6-4 |
EMC rating |
IEC 61000-6-2 |
Status indication
Note (LED switching conditions display) |
Veelkleurige LED: groen rood gele |
Pin assignment
PIN 1 |
1A1 Ue: (1) |
PIN 2 |
Y2 Veiligheidsuitgang 2 |
PIN 3 |
A2 GND |
PIN 4 |
Y1 Veiligheidsuitgang 1 |
Scope of delivery
Scope of delivery |
Actuator must be ordered separately. |
Accessory
Recommendation (actuator) |
CST 16-1 |
Recommended safety switchgear |
PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Note
Note (General) |
Vereisten voor de veiligheidsmodule: tweekanalige veiligheidsingang, geschikt voor p-schakelende sensoren met verbreekfunctie. De veiligheidsmodule moet de interne functietests van de sensoren met cyclische uitschakeling van de sensoruitgangen gedurende max. 0,25 ms tolereren. De veiligheidsmodule hoeft niet noodzakelijk met dwarssluitdetectie uitgerust te zijn. |
Taalfilter
Datasheet
Bedieningshandleiding en conformiteitsverklaring
UL-certificaat
SISTEMA-VDMA-bibliotheek/library
Download de nieuwste versie van Adobe Reader
Foto van het product (individuele catalogusfoto)
Foto van het product (individuele catalogusfoto)
Maatschets basistoestel
Karakteristiek diagram
103004370 RSS16-D-ST8H
- Universal coding with RFID technology
- 1 x connector plug M12, 8-pole
- Series-wiring unlimited
- without latching
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Door stop with magnetic latching
- Connection terminal or plug connection
- Suitable for series-wiring
- Repeated individual coding with RFID technology
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
De genoemde gegevens en informatie zijn zorgvuldig gecontroleerd. Afbeeldingen kunnen afwijken van het origineel. Verdere technische gegevens zijn te vinden in de handleiding. Technische wijzigingen en fouten voorbehouden.
Gegenereerd op 09-04-2025 08:49