SRB202MSL
SRB202MSL
Downloads
- Muting signalling device monitoring
- 2 safety contacts, STOP 0
- 2 Signalling outputs
Ordering data
Note (Delivery capacity) |
Niet meer verkrijgbaar! |
Product type description |
SRB202MSL |
Article number (order number) |
101181998 |
EAN (European Article Number) |
4250116202577 |
eCl@ss number, version 12.0 |
27-37-18-19 |
eCl@ss number, version 11.0 |
27-37-18-19 |
eCl@ss number, version 9.0 |
27-37-18-19 |
ETIM number, version 7.0 |
EC001449 |
ETIM number, version 6.0 |
EC001449 |
General data
Standards |
EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress |
EN 60068-2-78 |
Housing material |
Kunststof, glasvezelversterkte thermoplast, geventileerd |
Gross weight |
400 g |
General data - Features
Electronic Fuse |
Ja |
Wire breakage detection |
Ja |
Cross-circuit detection |
Ja |
Removable Terminals |
Ja |
Feedback circuit |
Ja |
Automatic reset function |
Ja |
Reset after disconnection of supply voltage |
Ja |
Earth connection detection |
Ja |
Integral system diagnostics, status |
Ja |
Number of auxiliary contacts |
2 |
Number of LEDs |
8 |
Number of normally closed (NC) |
2 |
Number of safety contacts |
2 |
Number of signalling outputs |
2 |
Safety classification |
Vorschriften |
EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category |
0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to |
e |
Category, Stop 0 |
4 |
Diagnostic Coverage (DC) Level, Stop 0 |
≥ 99 % |
PFH value, Stop 0 |
2,00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in |
3 |
Mission time |
20 Year(s) |
Common Cause Failure (CCF), minimum |
65 |
Mechanical data
Mechanical lifetime, minimum |
10.000.000 Operations |
Mounting |
Snelbevestiging voor DIN-rail volgens DIN EN 60715 |
Mechanical data - Connection technique
Terminal designations |
IEC/EN 60947-1 |
Cable section, minimum |
0,25 mm² |
Cable section, maximum |
2,5 mm² |
Tightening torque of Clips |
0,6 Nm |
Allowed type of cable |
solid single-wire flexible |
Terminal (mechanical) |
1000075113 |
Mechanical data - Dimensions
Width |
45 mm |
Height |
100 mm |
Depth |
121 mm |
Ambient conditions
Degree of protection of the enclosure |
IP40 |
Degree of protection of the installation space |
IP54 |
Degree of protection of clips or terminals |
IP20 |
Ambient temperature |
-25 ... +45 °C |
Storage and transport temperature |
-40 ... +85 °C |
Resistance to vibrations |
10...55 Hz, Amplitude 0,35 mm, ± 15 % |
Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp |
4 kV |
Overvoltage category |
III |
Degree of pollution |
2 |
Electrical data
Frequency range |
50 Hz 60 Hz |
Operating voltage |
24 VDC -10 % / +20 % |
Ripple voltage |
10 % |
Rated operating voltage |
24 VDC |
Rated AC voltage for controls at DC minimum |
20,4 VDC |
Rated control voltage at DC, maximum |
28,8 VDC |
Utilisation category DC-13 |
24 VDC |
Utilisation category DC-13 |
2 A |
Electrical power consumption |
5,6 W |
Contact resistance, maximum |
0,1 Ω |
Note (Contact resistance) |
In nieuwe toestand |
Drop-out delay in case of power failure, typically |
60 ms |
Drop-out delay in case of emergency, typically |
17 ms |
Drop-out delay in case of "emergency stop", maximum |
20 ms |
Pull-in delay at automatic start, maximum, typically |
200 ms |
Material of the contacts, electrical |
AgSn0, Ag-Ni, zelfreinigend, gedwongen uitgevoerd |
Electrical data - Digital inputs
Conduction resistance, maximum |
40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating |
EMC-Richtlijn |
Status indication
Indicated operating states |
Positie relais K2 Positie relais K1 Interne bedrijfsspanning Ui Positie relais K3 Positie relais K5 Positie van de muting signaallamp LA |
Other data
Note (applications) |
mutingfunctie |
Note
Note (General) |
Inductieve verbruikers (externe relais, enz.) zijn via een aangepaste bedrading te ontstoren. |
Wiring example
Note (Wiring diagram) |
Vermogensvlak: voldoet voor 2-kanalige aansturing,als contactversterking en/of contactvermenigvuldiging via externe relais met gedwongen uitgevoerde contacten. De sturing herkent dwarssluitingen, kabelbreuken en aardlekken in het bewakingscircuit. Het voorbeeld toont een 2-kanalige aansturing van 2 mutingsensoren en een externe master resetknop. Het schakelvoorbeeld is afgebeeld met niet-bediende mutingsensoren en in spanningsloze toestand. (H2) = Terugkoppeling F1 = Elektronische beveiliging |
Taalfilter
Datasheet
Montage- en aansluithandleiding
Bedieningshandleiding en conformiteitsverklaring
Schakelvoorbeeld (elektrische kabels)
Download de nieuwste versie van Adobe Reader
Foto van het product (individuele catalogusfoto)
Schakelvoorbeeld
Symbool (technische standaard)
Schmersal India Pvt. Ltd., Plot No - G-7/1, Ranjangaon MIDC, Tal. - Shirur, Dist.- Pune 412 220
De genoemde gegevens en informatie zijn zorgvuldig gecontroleerd. Afbeeldingen kunnen afwijken van het origineel. Verdere technische gegevens zijn te vinden in de handleiding. Technische wijzigingen en fouten voorbehouden.
Gegenereerd op 31-08-2025 02:22